Search in Category
Filter Your Search
Shop by Category
Fuses
PWR DIS BLK AL INT 310A 3P 1S
CSA Certified Class 6228 01; UL Listed to subject 1953, File E352417 unless noted otherwise
MOV FUSE 600V SR50KA
VSP fuses rated 600VAC, 200kA I.R.; ANSI/UL 248 Special Purpose MOV Fuse, File E60314; Surge ratings of 5-100kA 8/20 µSec capacity; Various mounting configurations ferrules, blade, bolt-in, PC board mount
CC TD FUSE 600V 3A ATQR
Inductive loads; High-grade silica filler ensures fast arc quenching and high current limitation; DC listed to UL standard 248; Rejection-style design prevents replacement errors (when used with recommended fuse blocks); Control transformers; High visibility orange label ensures instant brand recognition, and simplifies replacement; UL listed to standard 248-4 File E2137; Time-delay for control transformer inrush loads without nuisance opening; Lighting, heating & general-purpose loads; CSA certified to standard C22.2 No. 248.4; Highly current-limiting for low peak let-thru current; Metal-embossed date and catalog number for traceability and lasting identification; Fiberglass body provides dimensional stability in harsh industrial settings; Solenoids
FUSE, 160A,1000V AC
FUSE HOLDER,1-P,32A,600V,CLASS CC F
600V 10A CLASS J TD FUSE
Non-indicating or solid state SmartSpot visual blown fuse indicator; Small footprint requires less mounting space and allows smaller, more economical fuse blocks; Unique Class J dimensions prevent replacement errors; Fiberglass body provides dimensional stability in harsh industrial settings; Recommended for Arc Flash energy reduction; 300kA interrupting rating – self-certified, UL witnessed tests; Easy 2-to-1 selectivity for prevention of nuisance shutdowns; Circuit breaker back-up; Mains; Feeders; Transformers; Metal-embossed date and catalog number for traceability and lasting identification; UL listed to standard 248-8 File E2137; High-visibility orange label gives instant brand recognition; DC tested to UL standard 248; Motor circuits; High-grade silica filler ensures fast arc quenching; Bus duct; UL listed; Lighting, heating & general loads; IEC 60269-2-1; Extremely current-limiting for low peak let-thru current; Time-delay for motor starting and transformer inrush; CSA certified to standard C22.2 No. 248.8; Control panels; DC listed to UL standard 248; Branch circuits; Load centers; Most current-limiting UL class fuse; Optional EI indicator/switch mount for AJT70 to 600 open fuse indication
J TD FUSE 600V 40A AJT
Lighting, heating & general loads; Metal-embossed date and catalog number for traceability and lasting identification; Time-delay for motor starting and transformer inrush; High-grade silica filler ensures fast arc quenching; Bus duct; UL listed; Unique Class J dimensions prevent replacement errors; Non-indicating or solid state SmartSpot visual blown fuse indicator; High-visibility orange label gives instant brand recognition; Feeders; 300kA interrupting rating – self-certified, UL witnessed tests; Motor circuits; Circuit breaker back-up; Extremely current-limiting for low peak let-thru current; Mains; Control panels; Transformers; Fiberglass body provides dimensional stability in harsh industrial settings; DC listed to UL standard 248; Recommended for Arc Flash energy reduction; UL listed to standard 248-8 File E2137; Branch circuits; Load centers; Most current-limiting UL class fuse; Optional EI indicator/switch mount for AJT70 to 600 open fuse indication; IEC 60269-2-1; Easy 2-to-1 selectivity for prevention of nuisance shutdowns; DC tested to UL standard 248; CSA certified to standard C22.2 No. 248.8; Small footprint requires less mounting space and allows smaller, more economical fuse blocks
J TD FUSE 600V 45A AJT
Optional EI indicator/switch mount for AJT70 to 600 open fuse indication; Lighting, heating & general loads; Motor circuits; Bus duct; Fiberglass body provides dimensional stability in harsh industrial settings; CSA certified to standard C22.2 No. 248.8; DC tested to UL standard 248; Feeders; Control panels; Unique Class J dimensions prevent replacement errors; UL listed to standard 248-8 File E2137; Extremely current-limiting for low peak let-thru current; Easy 2-to-1 selectivity for prevention of nuisance shutdowns; Small footprint requires less mounting space and allows smaller, more economical fuse blocks; Non-indicating or solid state SmartSpot visual blown fuse indicator; Mains; Most current-limiting UL class fuse; Circuit breaker back-up; UL listed; High-visibility orange label gives instant brand recognition; DC listed to UL standard 248; Metal-embossed date and catalog number for traceability and lasting identification; 300kA interrupting rating – self-certified, UL witnessed tests; Load centers; Recommended for Arc Flash energy reduction; High-grade silica filler ensures fast arc quenching; Branch circuits; Transformers; IEC 60269-2-1; Time-delay for motor starting and transformer inrush
CC TD FUSE 600V 15A ATDR
High-grade silica filler ensures fast arc quenching and optimum current-limitation; Time-delay for motor starting inrush currents without nuisance opening; Lighting, heating & general loads; Improved cycling ability for frequent motor starts/stops without nuisance fuse opening; Fiberglass body provides dimensional stability in harsh industrial settings; Highly current-limiting for low peak let-thru current; Contactors; High-visibility orange label ensures instant brand recognition, simplifies replacement; Metal-embossed date and catalog number for traceability and lasting identification; CSA certified to standard C22.2 No. 248.4; Branch circuit protection; Small motors; DC listed to UL standard 248; Rejection-style design prevents replacement errors (when used with recommended fuse blocks); UL listed to standard 248-4 File E2137
CC TD FUSE 600V 20A ATDR
Branch circuit protection; High-grade silica filler ensures fast arc quenching and optimum current-limitation; CSA certified to standard C22.2 No. 248.4; Metal-embossed date and catalog number for traceability and lasting identification; Rejection-style design prevents replacement errors (when used with recommended fuse blocks); Time-delay for motor starting inrush currents without nuisance opening; Highly current-limiting for low peak let-thru current; Lighting, heating & general loads; Fiberglass body provides dimensional stability in harsh industrial settings; High-visibility orange label ensures instant brand recognition, simplifies replacement; Improved cycling ability for frequent motor starts/stops without nuisance fuse opening; DC listed to UL standard 248; Small motors; Contactors; UL listed to standard 248-4 File E2137