600V 80A RK1 TD FUSE
Safety switches; All general-purpose circuits; Time-delay for motor starting and transformer inrush currents without nuisance opening; DC listed to UL standard 248; Recommended for Arc Flash energy reduction; Branch circuit protection; Easy 2-to-1 selectivity for prevention of nuisance shut downs and “black outs”; Motors; Rejection-style design prevents replacement errors (when used with recommended fuse blocks); Extremely current-limiting for low peak let-thru current; Metal-embossed date and catalog number for easier traceability and lasting identification; Fiberglass body provides dimensional stability in harsh industrial settings; Transformers; UL listed to standard 248-12 File E2137; CSA certified to standard C22.2 No. 248.12; Solid state SmartSpot visual blown fuse indicator; Disconnects; 300kA interrupting rating – self-certified, UL witnessed tests; High-visibility orange label gives instant brand recognition; Reduced inventory by taking the place of class RK5, K, and H fuses; 600VAC & 600VDC dual rated; Control panels
600V 80A 7 7/8x1 5/16 TD
Branch circuits; Feeders; Metal-embossed date and catalog number for traceability and lasting identification; General-purpose equipment; Service entrance equipment; AC & DC rated; Easy-to-read label for quick brand recognition and replacement; Optional solid state SmartSpot blown fuse indicator; UL listed to standard 248-12 File E2137; Time-delay for motor start-ups and transformer inrush currents without nuisance opening; Current-limiting for low peak let-thru current; Current-limiting; High-grade silica filler ensures fast arc quenching and high current limitation; Rejection-style design prevents replacement errors (when used with recommended fuse blocks); Motor circuits; DC listed to UL standard 248 TRS only; Time-delay; Fiberglass body provides dimensional stability in harsh industrial settings; Mains; CSA certified to standard C22.2 no. 248.12; Transformers
600V 70A RK1 TD FUSE
Transformers; Motors; Time-delay for motor starting and transformer inrush currents without nuisance opening; 300kA interrupting rating – self-certified, UL witnessed tests; Solid state SmartSpot visual blown fuse indicator; Fiberglass body provides dimensional stability in harsh industrial settings; Control panels; Extremely current-limiting for low peak let-thru current; Branch circuit protection; High-visibility orange label gives instant brand recognition; Disconnects; Recommended for Arc Flash energy reduction; Rejection-style design prevents replacement errors (when used with recommended fuse blocks); Metal-embossed date and catalog number for easier traceability and lasting identification; DC listed to UL standard 248; CSA certified to standard C22.2 No. 248.12; All general-purpose circuits; Safety switches; UL listed to standard 248-12 File E2137; Easy 2-to-1 selectivity for prevention of nuisance shut downs and “black outs”; Reduced inventory by taking the place of class RK5, K, and H fuses; 600VAC & 600VDC dual rated
600V 90A RK1 TD FUSE
CSA certified to standard C22.2 No. 248.12; Solid state SmartSpot visual blown fuse indicator; 300kA interrupting rating – self-certified, UL witnessed tests; Control panels; High-visibility orange label gives instant brand recognition; Disconnects; Recommended for Arc Flash energy reduction; All general-purpose circuits; Metal-embossed date and catalog number for easier traceability and lasting identification; Transformers; Branch circuit protection; DC listed to UL standard 248; Fiberglass body provides dimensional stability in harsh industrial settings; 600VAC & 600VDC dual rated; Easy 2-to-1 selectivity for prevention of nuisance shut downs and “black outs”; UL listed to standard 248-12 File E2137; Rejection-style design prevents replacement errors (when used with recommended fuse blocks); Reduced inventory by taking the place of class RK5, K, and H fuses; Safety switches; Time-delay for motor starting and transformer inrush currents without nuisance opening; Motors; Extremely current-limiting for low peak let-thru current
600V 100A RK1 FUSE
Load centers; Rejection style design prevents replacement by other fuse classes; Easy-to-read imprint label for quick recognition and replacement; High degree of current limitation for low peak let-thru current; Fiberglass body provides dimensional stability in harsh industrial environments; Non-inductive loads; CSA certified to standard C22.2 No. 248.12; UL listed to standard 248-12 File E2137; Feeder circuits; Lighting circuits; Self-certified for DC per UL248; Switchboards; Bus duct; Panelboards
600V 70A 7 7/8x1 5/16 K5 FUSE
Self-certified for DC per UL248; UL Listed to Standard 248-9 File E2137; CSA Certified to Standard C22.2 No. 248.9 (The Canadian Electrical Code requires these fuses in ratings 15 through 60A to be of the low melting point design; use OTN 15-60.); Residential and small commercial installations; Low cost for high protection value; Easy to read imprint label for quick recognition and replacement; Resistive heating; Feeders; Branch circuits
600V 75A 7 7/8x1 5/16 K5 FUSE
Easy to read imprint label for quick recognition and replacement; CSA Certified to Standard C22.2 No. 248.9 (The Canadian Electrical Code requires these fuses in ratings 15 through 60A to be of the low melting point design; use OTN 15-60.); Branch circuits; UL Listed to Standard 248-9 File E2137; Feeders; Residential and small commercial installations; Resistive heating; Self-certified for DC per UL248; Low cost for high protection value
600V 80A 7 7/8x1 5/16 K5 FUSE
Feeders; Branch circuits; Residential and small commercial installations; Easy to read imprint label for quick recognition and replacement; CSA Certified to Standard C22.2 No. 248.9 (The Canadian Electrical Code requires these fuses in ratings 15 through 60A to be of the low melting point design; use OTN 15-60.); Self-certified for DC per UL248; Low cost for high protection value; Resistive heating; UL Listed to Standard 248-9 File E2137
600V 90A 7 7/8x1 5/16 K5 FUSE
Resistive heating; Low cost for high protection value; CSA Certified to Standard C22.2 No. 248.9 (The Canadian Electrical Code requires these fuses in ratings 15 through 60A to be of the low melting point design; use OTN 15-60.); Branch circuits; Easy to read imprint label for quick recognition and replacement; Feeders; Self-certified for DC per UL248; UL Listed to Standard 248-9 File E2137; Residential and small commercial installations
600V 70A 7 7/8x1 5/16 TD
Optional solid state SmartSpot blown fuse indicator; Rejection-style design prevents replacement errors (when used with recommended fuse blocks); High-grade silica filler ensures fast arc quenching and high current limitation; Current-limiting; Easy-to-read label for quick brand recognition and replacement; Metal-embossed date and catalog number for traceability and lasting identification; General-purpose equipment; Motor circuits; Current-limiting for low peak let-thru current; Time-delay for motor start-ups and transformer inrush currents without nuisance opening; Mains; Transformers; Fiberglass body provides dimensional stability in harsh industrial settings; CSA certified to standard C22.2 no. 248.12; DC listed to UL standard 248 TRS only; Branch circuits; AC & DC rated; UL listed to standard 248-12 File E2137; Service entrance equipment; Feeders; Time-delay