Fuses
600V 90A RK1 FUSE
High degree of current limitation for low peak let-thru current; Feeder circuits; Lighting circuits; Bus duct; UL listed to standard 248-12 File E2137; Switchboards; Self-certified for DC per UL248; Load centers; CSA certified to standard C22.2 No. 248.12; Rejection style design prevents replacement by other fuse classes; Non-inductive loads; Panelboards; Fiberglass body provides dimensional stability in harsh industrial environments; Easy-to-read imprint label for quick recognition and replacement
600V 70A 7 7/8x1 5/16 TD
Optional solid state SmartSpot blown fuse indicator; Rejection-style design prevents replacement errors (when used with recommended fuse blocks); High-grade silica filler ensures fast arc quenching and high current limitation; Current-limiting; Easy-to-read label for quick brand recognition and replacement; Metal-embossed date and catalog number for traceability and lasting identification; General-purpose equipment; Motor circuits; Current-limiting for low peak let-thru current; Time-delay for motor start-ups and transformer inrush currents without nuisance opening; Mains; Transformers; Fiberglass body provides dimensional stability in harsh industrial settings; CSA certified to standard C22.2 no. 248.12; DC listed to UL standard 248 TRS only; Branch circuits; AC & DC rated; UL listed to standard 248-12 File E2137; Service entrance equipment; Feeders; Time-delay
600V 70A TD RK5 FUSE SMARTSPOT
Time-delay; DC listed to UL standard 248 TRS only; Motor circuits; Transformers; Time-delay for motor start-ups and transformer inrush currents without nuisance opening; CSA certified to standard C22.2 no. 248.12; Current-limiting for low peak let-thru current; Metal-embossed date and catalog number for traceability and lasting identification; Rejection-style design prevents replacement errors (when used with recommended fuse blocks); UL listed to standard 248-12 File E2137; Branch circuits; Current-limiting; Service entrance equipment; AC & DC rated; Mains; General-purpose equipment; Optional solid state SmartSpot blown fuse indicator; High-grade silica filler ensures fast arc quenching and high current limitation; Fiberglass body provides dimensional stability in harsh industrial settings; Feeders; Easy-to-read label for quick brand recognition and replacement
600V 75A 7 7/8x1 5/16 TD
Mains; Feeders; Transformers; Time-delay for motor start-ups and transformer inrush currents without nuisance opening; Motor circuits; Branch circuits; General-purpose equipment; Optional solid state SmartSpot blown fuse indicator; Easy-to-read label for quick brand recognition and replacement; High-grade silica filler ensures fast arc quenching and high current limitation; CSA certified to standard C22.2 no. 248.12; DC listed to UL standard 248 TRS only; Current-limiting; Time-delay; Current-limiting for low peak let-thru current; UL listed to standard 248-12 File E2137; AC & DC rated; Service entrance equipment; Metal-embossed date and catalog number for traceability and lasting identification; Rejection-style design prevents replacement errors (when used with recommended fuse blocks); Fiberglass body provides dimensional stability in harsh industrial settings
600V 90A 7 7/8x1 5/16 TD
Service entrance equipment; Motor circuits; Rejection-style design prevents replacement errors (when used with recommended fuse blocks); Optional solid state SmartSpot blown fuse indicator; UL listed to standard 248-12 File E2137; Time-delay for motor start-ups and transformer inrush currents without nuisance opening; High-grade silica filler ensures fast arc quenching and high current limitation; Time-delay; Branch circuits; DC listed to UL standard 248 TRS only; Easy-to-read label for quick brand recognition and replacement; General-purpose equipment; CSA certified to standard C22.2 no. 248.12; Mains; AC & DC rated; Current-limiting; Transformers; Current-limiting for low peak let-thru current; Fiberglass body provides dimensional stability in harsh industrial settings; Metal-embossed date and catalog number for traceability and lasting identification; Feeders
600V 90A TD RK5 FUSE SMARTSPOT
Mains; UL listed to standard 248-12 File E2137; Current-limiting for low peak let-thru current; CSA certified to standard C22.2 no. 248.12; Feeders; Time-delay; High-grade silica filler ensures fast arc quenching and high current limitation; Time-delay for motor start-ups and transformer inrush currents without nuisance opening; General-purpose equipment; Optional solid state SmartSpot blown fuse indicator; Fiberglass body provides dimensional stability in harsh industrial settings; Transformers; Branch circuits; DC listed to UL standard 248 TRS only; AC & DC rated; Metal-embossed date and catalog number for traceability and lasting identification; Rejection-style design prevents replacement errors (when used with recommended fuse blocks); Motor circuits; Current-limiting; Service entrance equipment; Easy-to-read label for quick brand recognition and replacement