Search in Category
Search Filters
-
8.75 lb x
Filter Your Search
Shop by Category
Fuses
L TD FUSE 600V 1800A A4BT
Self-certified for DC per UL248 (601-2000); Blade-stamped catalog numbers for permanent identification; Unique dimensions prevent replacement by other fuse classes.; Glass melamine body and plated terminals provide superior reliability in harsh environments; Mains; Transformers; UL Listed to Standard 248-10, File E2137; CSA Certified to Standard C22.2, No. 248.68; Motors; Feeders; Motor controllers
L TD FUSE 600V 1800A A4BY
Blade-stamped catalog numbers for permanent identification; Unique dimensions prevent replacement by other fuse classes; Mains; Circuit Breakers; Switchboards; Panelboards; Feeders; CSA Certified to Standard C22.2, No. 248.10 IEC 269-2-1; DC Tested to UL 248 limits (Mersen Self-Certified); Load centers; Glass melamine body and plated terminals provide superior reliability in harsh environments; Metering Centers; Mersen Self-Certification, UL Listed to Standard 248-10, File E2137
L TD FUSE 600V 2000A A4BQ
Feeders; 300kA interrupting rating – self-certified, UL witnessed tests; Time-delay for high inrush loads such as motors and transformers, without nuisance opening; Fastest operation under short circuit conditions: Let-thru currents are typically 20 percent lower, with a corresponding let-thru energy (clearing I2t) up to 40% lower than the next fastest Class L fuse; High-grade silica filler ensures fast arc quenching; Pure silver links ensure lowest let-thru current and longer fuse life; Reduced inventory because A4BQ can replace all older types of Class L fuses now in-service; DC listed to UL standard 248 (100-2000A); Optional mechanical TA indicator (100-6000A). Please contact factory for special trigger actuator; CSA certified to standard C22.2 No. 248.10 (601-6000A); UL listed to standard 248-10 File E2137; Mains; Metal-embossed date and catalog number for traceability and lasting identification; Most current-limiting for lowest peak let-thru current; even at fault currents up to 300kA; Lighting, heating & general loads; Rejection-style design prevents replacement errors; Circuit breaker back-up; High-visibility orange label gives instant brand recognition; Easy 2-to-1 selectivity for prevention of nuisance shutdowns and “blackouts”; Large motors; Fiberglass body provides dimensional stability in harsh industrial settings; Recommended for Arc Flash energy reduction; UL listed
L TD FUSE 600V 2000A A4BT
Blade-stamped catalog numbers for permanent identification; Motor controllers; Self-certified for DC per UL248 (601-2000); Unique dimensions prevent replacement by other fuse classes.; Motors; Transformers; Feeders; UL Listed to Standard 248-10, File E2137; CSA Certified to Standard C22.2, No. 248.68; Mains; Glass melamine body and plated terminals provide superior reliability in harsh environments
L TD FUSE 600V 1800A A4BQ
Recommended for Arc Flash energy reduction; CSA certified to standard C22.2 No. 248.10 (601-6000A); UL listed; Large motors; High-visibility orange label gives instant brand recognition; High-grade silica filler ensures fast arc quenching; Optional mechanical TA indicator (100-6000A). Please contact factory for special trigger actuator; Feeders; Lighting, heating & general loads; Time-delay for high inrush loads such as motors and transformers, without nuisance opening; Circuit breaker back-up; UL listed to standard 248-10 File E2137; 300kA interrupting rating – self-certified, UL witnessed tests; Pure silver links ensure lowest let-thru current and longer fuse life; Fastest operation under short circuit conditions: Let-thru currents are typically 20 percent lower, with a corresponding let-thru energy (clearing I2t) up to 40% lower than the next fastest Class L fuse; Fiberglass body provides dimensional stability in harsh industrial settings; Mains; Reduced inventory because A4BQ can replace all older types of Class L fuses now in-service; Most current-limiting for lowest peak let-thru current; even at fault currents up to 300kA; DC listed to UL standard 248 (100-2000A); Rejection-style design prevents replacement errors; Metal-embossed date and catalog number for traceability and lasting identification; Easy 2-to-1 selectivity for prevention of nuisance shutdowns and “blackouts”
CLASS L - 1900A
Metal-embossed date and catalog number for traceability and lasting identification; High-grade silica filler ensures fast arc quenching; Time-delay for high inrush loads such as motors and transformers, without nuisance opening; Mains; High-visibility orange label gives instant brand recognition; Lighting, heating & general loads; 300kA interrupting rating – self-certified, UL witnessed tests; Optional mechanical TA indicator (100-6000A). Please contact factory for special trigger actuator; Fastest operation under short circuit conditions: Let-thru currents are typically 20 percent lower, with a corresponding let-thru energy (clearing I2t) up to 40% lower than the next fastest Class L fuse; DC listed to UL standard 248 (100-2000A); Circuit breaker back-up; UL listed to standard 248-10 File E2137; Recommended for Arc Flash energy reduction; Reduced inventory because A4BQ can replace all older types of Class L fuses now in-service; Easy 2-to-1 selectivity for prevention of nuisance shutdowns and “blackouts”; Fiberglass body provides dimensional stability in harsh industrial settings; Rejection-style design prevents replacement errors; Pure silver links ensure lowest let-thru current and longer fuse life; Most current-limiting for lowest peak let-thru current; even at fault currents up to 300kA; Feeders; Large motors; CSA certified to standard C22.2 No. 248.10 (601-6000A); UL listed
600V 1601A L TD FUSE
Blade-stamped catalog numbers for permanent identification; Metering Centers; Feeders; Load centers; DC Tested to UL 248 limits (Mersen Self-Certified); Mersen Self-Certification, UL Listed to Standard 248-10, File E2137; Circuit Breakers; Glass melamine body and plated terminals provide superior reliability in harsh environments; CSA Certified to Standard C22.2, No. 248.10 IEC 269-2-1; Unique dimensions prevent replacement by other fuse classes; Panelboards; Switchboards; Mains
L TD FUSE 600V 2000A A4BY
Mersen Self-Certification, UL Listed to Standard 248-10, File E2137; Metering Centers; Circuit Breakers; DC Tested to UL 248 limits (Mersen Self-Certified); Glass melamine body and plated terminals provide superior reliability in harsh environments; CSA Certified to Standard C22.2, No. 248.10 IEC 269-2-1; Feeders; Panelboards; Switchboards; Unique dimensions prevent replacement by other fuse classes; Load centers; Mains; Blade-stamped catalog numbers for permanent identification