Browse Categories

Search in Category

Fuses

Search Filters

  • Germany x

Shop by Category

Loading...

Fuses

Power Products/Fuses 
Viewing Page 1 of 5 (45 results)
1000VDC NH1 gPV 80A

1000VDC NH1 gPV 80A

Item #: B1028285

Supplier Part #: B1028285
Brand: Mersen

Mersen HP10NH photovoltaic (PV) fuse series was engineered and designed specifically for the protection of photovoltaic systems. Helio-Protection® HP10NH fuse links are designed for the protection of cables in a PV group of chains when a short circuit occurs in a panel (main fuse category). This HelioProtection® main fuse range enlarges our PV fuse links offering on a size having a worldwide acceptance. They are of the gPV type and comply with both IEC 60269-6 and UL 2579 PV standards. They are also available with bolted type blades for direct mounting.

UL 2579; RoHS compliance; Durable construction for enhanced system longevity; IEC 60269-6; Temperature cycle withstand capability; Low fault current interrupting capability; Global acceptance; Small footprint; High efficiency with low power losses

$437.70 /EA
NOT CURRENTLY IN STOCK
1250VDC NH3L GPV 350A

1250VDC NH3L GPV 350A

Item #: B1033391

Supplier Part #: B1033391
Brand: Mersen

Mersen HP12NH photovoltaic (PV) fuse series was engineered and designed specifically for the protection of photovoltaic systems. Helio-Protection® HP12NH fuse links are designed for the protection of cables in a PV group of chains when a short circuit occurs in a panel (main fuse category). This HelioProtection® main fuse range enlarges our PV fuse links offering on a size having a worldwide acceptance. They are of the gPV type and comply with both IEC 60269-6 and UL 2579 PV standards. They are also available with bolted type blades for direct mounting.

Durable construction for enhanced system longevity; Temperature cycle withstand capability; High efficiency with low power losses; Low fault current interrupting capability; IEC 60269-6; Global acceptance; RoHS compliance; UL 2579

$864.61 /EA
NOT CURRENTLY IN STOCK
1250VDC NH3L gPV 400A

1250VDC NH3L gPV 400A

Item #: C1033392

Supplier Part #: C1033392
Brand: Mersen

Mersen HP12NH photovoltaic (PV) fuse series was engineered and designed specifically for the protection of photovoltaic systems. Helio-Protection® HP12NH fuse links are designed for the protection of cables in a PV group of chains when a short circuit occurs in a panel (main fuse category). This HelioProtection® main fuse range enlarges our PV fuse links offering on a size having a worldwide acceptance. They are of the gPV type and comply with both IEC 60269-6 and UL 2579 PV standards. They are also available with bolted type blades for direct mounting.

Global acceptance; RoHS compliance; Durable construction for enhanced system longevity; High efficiency with low power losses; Temperature cycle withstand capability; IEC 60269-6; UL 2579; Low fault current interrupting capability

$874.20 /EA
NOT CURRENTLY IN STOCK

DIII-SICH.EINSATZ 35A GL-GG

Item #: C214063

Supplier Part #: C214063
Brand: Mersen

The D fuse-system is the first generation of screw fuse-system in the german DIN standard. It is still used in many installations. Applications are low voltage ditribution units, where non trained persons are allowed to change the fuse-links. The D fuse range comprises the sizes NDZ, DII, DIII, DIV, DV. The range of applications for D fuse-links is the protection of cables and power lines. They limit and cut-off unacceptable overcurrents and short circuit currents up to their nominal breaking capacity. D fuse-links "gG" also protect equipments and installations against dynamic effects of high short circuit currents.

Insulated body suitable for high mechanical and thermal impacts; Clear indication of operation condition due to coloured indicator on top contact; DIN VDE 0636-301; Optimized size; Free of lead, cadmium, mercury, chrome 6 (rohs conformity); Low power dissipation; Resistant to aging; Top and bottom contacts made of nickel plated copper alloy; Safe cut-off short circuits and over currents due to special design of fuse element

$42.82 /EA
NOT CURRENTLY IN STOCK

DII-SICH.EINSATZ 4A FLINK

Item #: D214064

Supplier Part #: D214064
Brand: Mersen

The D fuse-system is the first generation of screw fuse-system in the german DIN standard. It is still used in many installations. Applications are low voltage ditribution units, where non trained persons are allowed to change the fuse-links. The D flink fuse range comprises the sizes NDZ, DII, DIII. The range of applications for D flink fuse-links is the protection of equipments. The D flink fuse-links, not standardized by the IEC, are fast fuse-links whereas D gG fuse links are considered in comparison as slow fuse-links.

Clear indication of operation condition due to coloured indicator on top contact; Low power dissipation; Resistant to aging; Insulated body suitable for high mechanical and thermal impacts; Optimized size; Free of lead, cadmium, mercury, chrome 6 (rohs conformity); Top and bottom contacts made of nickel plated copper alloy; Safe cut-off short circuits and over currents due to special design of fuse element

$25.36 /EA
NOT CURRENTLY IN STOCK

DV-SICH.EINSATZ 160A GL-GG

Item #: G218667

Supplier Part #: G218667
Brand: Mersen

The D fuse-system is the first generation of screw fuse-system in the german DIN standard. It is still used in many installations. Applications are low voltage ditribution units, where non trained persons are allowed to change the fuse-links. The D fuse range comprises the sizes NDZ, DII, DIII, DIV, DV. The range of applications for D fuse-links is the protection of cables and power lines. They limit and cut-off unacceptable overcurrents and short circuit currents up to their nominal breaking capacity. D fuse-links "gG" also protect equipments and installations against dynamic effects of high short circuit currents.

DIN VDE 0636-301; Low power dissipation; Top and bottom contacts made of nickel plated copper alloy; Optimized size; Insulated body suitable for high mechanical and thermal impacts; Free of lead, cadmium, mercury, chrome 6 (rohs conformity); Resistant to aging; Safe cut-off short circuits and over currents due to special design of fuse element; Clear indication of operation condition due to coloured indicator on top contact

$238.02 /EA
NOT CURRENTLY IN STOCK

DII-SICH.EINSATZ 20A FLINK

Item #: J217128

Supplier Part #: J217128
Brand: Mersen

The D fuse-system is the first generation of screw fuse-system in the german DIN standard. It is still used in many installations. Applications are low voltage ditribution units, where non trained persons are allowed to change the fuse-links. The D flink fuse range comprises the sizes NDZ, DII, DIII. The range of applications for D flink fuse-links is the protection of equipments. The D flink fuse-links, not standardized by the IEC, are fast fuse-links whereas D gG fuse links are considered in comparison as slow fuse-links.

Free of lead, cadmium, mercury, chrome 6 (rohs conformity); Insulated body suitable for high mechanical and thermal impacts; Safe cut-off short circuits and over currents due to special design of fuse element; Low power dissipation; Optimized size; Resistant to aging; Top and bottom contacts made of nickel plated copper alloy; Clear indication of operation condition due to coloured indicator on top contact

$5.91 /EA
NOT CURRENTLY IN STOCK
DII-RECTI.EINSATZ 4A 500V GR

DII-RECTI.EINSATZ 4A 500V GR

Item #: K213058

Supplier Part #: K213058
Brand: Mersen

The D fuse-system is the first generation of screw fuse-systems in the German DIN standard. It is still used in many installations. This D system comprises the sizes DII, DIII, DIV, DV. Those D ultra-fast acting “gR” ranges are dedicated to semi-conductor protection, in applications where fuse-links are accessible to non-trained persons and can also be changed by them. They are used for the protection of components such as diodes, thyristors or AC/DC motor drives. The “R” stands for the English word Rectifier. D fuse-links are available at the rated current range from 2A up to 200A.

DIN EN 60269-4 (VDE 0636-4); Resistant to aging; Insulated body suitable for high mechanical and thermal impacts; DIN VDE 0636-3; Top and bottom contacts made of nickel-plated/silver-plated copper alloy; Optimized size; Clear indication of operation condition due coloured indicator on top contact; IEC 60 269-4; Safe cut off short circuits and over currents due special design of fuse element; Low power dissipation

$31.23 /EA
NOT CURRENTLY IN STOCK

DIII-S.EINSATZ 35A 500V GR

Item #: K217129

Supplier Part #: K217129
Brand: Mersen

The D fuse-system is the first generation of screw fuse-systems in the German DIN standard. It is still used in many installations. This D system comprises the sizes DII, DIII, DIV, DV. Those D ultra-fast acting “gR” ranges are dedicated to semi-conductor protection, in applications where fuse-links are accessible to non-trained persons and can also be changed by them. They are used for the protection of components such as diodes, thyristors or AC/DC motor drives. The “R” stands for the English word Rectifier. D fuse-links are available at the rated current range from 2A up to 200A.

Low power dissipation; Top and bottom contacts made of nickel-plated/silver-plated copper alloy; Optimized size; Resistant to aging; IEC 60 269-4; DIN EN 60269-4 (VDE 0636-4); DIN VDE 0636-3; Insulated body suitable for high mechanical and thermal impacts; Clear indication of operation condition due coloured indicator on top contact; Safe cut off short circuits and over currents due special design of fuse element

$151.51 /EA
NOT CURRENTLY IN STOCK

DII-SICH.SOCKEL 1POL.

Item #: K218670

Supplier Part #: K218670
Brand: Mersen

The D fuse-system is the first generation of the screw fuse-system in the german DIN standard. It is still used in many installations. Applications are low voltage ditribution units, where non trained persons are allowed to change the fuse-links. The D fuse-range comprises the sizes NDZ, DII, DIII, DIV, DV. The range of applications for D fuse-links "gG" is the protection of cables and power lines. They limit and cut off unacceptable overcurrents and short circuit currents up to their nominal breaking capacity. D fuse-links "gG" also protect equipments and installations against dynamic effects of high short circuit currents.

Resistant to aging; DIN VDE 0636-3; Insulated body suitable for high mechanical and thermal impacts; Top and bottom contacts made of nickel plated copper alloy; Clear indication of operation condition due to coloured indicator on top contact; Optimized size; Safe cut off short circuits and over currents due to special design of fuse element; Low power dissipation; Free of lead, cadmium, mercury, chrome 6 (rohs conformity)

$38.76 /EA
NOT CURRENTLY IN STOCK
  • 1
  • 2
  • 3
  • 4
  • 5