Search in Category
Search Filters
-
0.94 lb x
Filter Your Search
Shop by Category
Fuses
250V 200A RK1 TD FUSE
Solid state SmartSpot visual blown fuse indicator; Easy 2-to-1 selectivity for prevention of nuisance shut downs and “black outs”; Reduced inventory by taking the place of class RK5, K, and H fuses; 300kA interrupting rating – self-certified, UL witnessed tests; Recommended for Arc Flash energy reduction; Rejection-style design prevents replacement errors (when used with recommended fuse blocks); High-visibility orange label gives instant brand recognition; Branch circuit protection; CSA certified to standard C22.2 No. 248.12; Time-delay for motor starting and transformer inrush currents without nuisance opening; Extremely current-limiting for low peak let-thru current; Motors; All general-purpose circuits; Metal-embossed date and catalog number for easier traceability and lasting identification; Transformers; Fiberglass body provides dimensional stability in harsh industrial settings; Disconnects; 600VAC & 600VDC dual rated; DC listed to UL standard 248; UL listed to standard 248-12 File E2137; Safety switches; Control panels
250V 110A RK1 TD FUSE
Fiberglass body provides dimensional stability in harsh industrial settings; Motors; UL listed to standard 248-12 File E2137; 300kA interrupting rating – self-certified, UL witnessed tests; CSA certified to standard C22.2 No. 248.12; Transformers; Time-delay for motor starting and transformer inrush currents without nuisance opening; Extremely current-limiting for low peak let-thru current; Safety switches; Disconnects; 600VAC & 600VDC dual rated; Reduced inventory by taking the place of class RK5, K, and H fuses; Control panels; Solid state SmartSpot visual blown fuse indicator; DC listed to UL standard 248; Recommended for Arc Flash energy reduction; High-visibility orange label gives instant brand recognition; Rejection-style design prevents replacement errors (when used with recommended fuse blocks); Metal-embossed date and catalog number for easier traceability and lasting identification; Easy 2-to-1 selectivity for prevention of nuisance shut downs and “black outs”; All general-purpose circuits; Branch circuit protection
250V 125A RK1 TD FUSE
Control panels; Recommended for Arc Flash energy reduction; Transformers; 300kA interrupting rating – self-certified, UL witnessed tests; Reduced inventory by taking the place of class RK5, K, and H fuses; Motors; Metal-embossed date and catalog number for easier traceability and lasting identification; CSA certified to standard C22.2 No. 248.12; Disconnects; Solid state SmartSpot visual blown fuse indicator; Easy 2-to-1 selectivity for prevention of nuisance shut downs and “black outs”; All general-purpose circuits; UL listed to standard 248-12 File E2137; DC listed to UL standard 248; Extremely current-limiting for low peak let-thru current; 600VAC & 600VDC dual rated; High-visibility orange label gives instant brand recognition; Safety switches; Fiberglass body provides dimensional stability in harsh industrial settings; Branch circuit protection; Rejection-style design prevents replacement errors (when used with recommended fuse blocks); Time-delay for motor starting and transformer inrush currents without nuisance opening
250V 150A RK1 TD FUSE
CSA certified to standard C22.2 No. 248.12; Branch circuit protection; Recommended for Arc Flash energy reduction; UL listed to standard 248-12 File E2137; High-visibility orange label gives instant brand recognition; Metal-embossed date and catalog number for easier traceability and lasting identification; Motors; Reduced inventory by taking the place of class RK5, K, and H fuses; Rejection-style design prevents replacement errors (when used with recommended fuse blocks); All general-purpose circuits; Fiberglass body provides dimensional stability in harsh industrial settings; DC listed to UL standard 248; 600VAC & 600VDC dual rated; Disconnects; Safety switches; 300kA interrupting rating – self-certified, UL witnessed tests; Easy 2-to-1 selectivity for prevention of nuisance shut downs and “black outs”; Transformers; Solid state SmartSpot visual blown fuse indicator; Time-delay for motor starting and transformer inrush currents without nuisance opening; Extremely current-limiting for low peak let-thru current; Control panels
250V 175A RK1 TD FUSE
Transformers; Time-delay for motor starting and transformer inrush currents without nuisance opening; Reduced inventory by taking the place of class RK5, K, and H fuses; Branch circuit protection; Metal-embossed date and catalog number for easier traceability and lasting identification; 600VAC & 600VDC dual rated; Fiberglass body provides dimensional stability in harsh industrial settings; Extremely current-limiting for low peak let-thru current; Rejection-style design prevents replacement errors (when used with recommended fuse blocks); Easy 2-to-1 selectivity for prevention of nuisance shut downs and “black outs”; DC listed to UL standard 248; Control panels; High-visibility orange label gives instant brand recognition; Disconnects; Motors; All general-purpose circuits; Solid state SmartSpot visual blown fuse indicator; 300kA interrupting rating – self-certified, UL witnessed tests; Recommended for Arc Flash energy reduction; Safety switches; CSA certified to standard C22.2 No. 248.12; UL listed to standard 248-12 File E2137