Search in Category
Search Filters
-
7.13 in x
Filter Your Search
Shop by Category
Fuses
600V 400A CLASS J TD FUSE
IEC 60269-2-1; UL listed; High-grade silica filler ensures fast arc quenching; Optional EI indicator/switch mount for AJT70 to 600 open fuse indication; High-visibility orange label gives instant brand recognition; Motor circuits; Control panels; Metal-embossed date and catalog number for traceability and lasting identification; Unique Class J dimensions prevent replacement errors; DC tested to UL standard 248; UL listed to standard 248-8 File E2137; Load centers; DC listed to UL standard 248; Transformers; Mains; Feeders; Extremely current-limiting for low peak let-thru current; Easy 2-to-1 selectivity for prevention of nuisance shutdowns; 300kA interrupting rating – self-certified, UL witnessed tests; Lighting, heating & general loads; Fiberglass body provides dimensional stability in harsh industrial settings; Circuit breaker back-up; Recommended for Arc Flash energy reduction; Non-indicating or solid state SmartSpot visual blown fuse indicator; Most current-limiting UL class fuse; Bus duct; Branch circuits; CSA certified to standard C22.2 No. 248.8; Time-delay for motor starting and transformer inrush; Small footprint requires less mounting space and allows smaller, more economical fuse blocks
600V 350A CLASS J FUSE
Unique dimensions prevent replacement by other fuse classes; Capacitors; Lighting, heating, and general loads; Switchboards; DC listed to UL 248; IEC 269-2-1; Circuit breakers; Bus duct; High current limitation for low peak let-thru current; UL listed to standard 248-8 File E2137; CSA certified to standard C22.2 no. 248.8; Panelboards; Load centers; Fiberglass body provides dimensional stability in harsh industrial environments; Easy-to-read imprint label for quick recognition and replacement; Feeder circuits
600V 350A CLASS J HS FUSE
Optimized over-load capability for withstanding elevated levels of current during electronic motor controller starts; UL listed to standard 248-8 File E2137; Low I2t (low thermal energy); Branch circuits; Solid state relays; CSA certified to standard C22.2 no. 248.8; DC listed to UL 248; Control panels; Electronic motor controllers; Drives; Soft-starters; Excellent cycling ability for frequent starts/stops without nuisance opening; Phase controllers
600V 400A CLASS J HS FUSE
UL listed to standard 248-8 File E2137; Control panels; Branch circuits; Low I2t (low thermal energy); Phase controllers; Optimized over-load capability for withstanding elevated levels of current during electronic motor controller starts; CSA certified to standard C22.2 no. 248.8; DC listed to UL 248; Electronic motor controllers; Soft-starters; Excellent cycling ability for frequent starts/stops without nuisance opening; Solid state relays; Drives
600V 250A CLASS J FUSE
IEC 269-2-1; Feeder circuits; UL listed to standard 248-8 File E2137; Switchboards; Circuit breakers; DC listed to UL 248; Lighting, heating, and general loads; Fiberglass body provides dimensional stability in harsh industrial environments; Bus duct; Load centers; CSA certified to standard C22.2 no. 248.8; Unique dimensions prevent replacement by other fuse classes; Easy-to-read imprint label for quick recognition and replacement; Capacitors; High current limitation for low peak let-thru current; Panelboards
600V 225A CLASS J HS FUSE
Drives; Electronic motor controllers; DC listed to UL 248; Excellent cycling ability for frequent starts/stops without nuisance opening; Branch circuits; UL listed to standard 248-8 File E2137; Phase controllers; Solid state relays; CSA certified to standard C22.2 no. 248.8; Low I2t (low thermal energy); Control panels; Optimized over-load capability for withstanding elevated levels of current during electronic motor controller starts; Soft-starters
J TD FUSE 600V 225A AJT EIB
Non-indicating or solid state SmartSpot visual blown fuse indicator; 300kA interrupting rating – self-certified, UL witnessed tests; Unique Class J dimensions prevent replacement errors; Most current-limiting UL class fuse; Lighting, heating & general loads; Bus duct; High-visibility orange label gives instant brand recognition; Mains; Branch circuits; High-grade silica filler ensures fast arc quenching; Optional EI indicator/switch mount for AJT70 to 600 open fuse indication; Load centers; UL listed to standard 248-8 File E2137; Recommended for Arc Flash energy reduction; Control panels; DC tested to UL standard 248; Motor circuits; Transformers; UL listed; Feeders; DC listed to UL standard 248; Extremely current-limiting for low peak let-thru current; IEC 60269-2-1; Fiberglass body provides dimensional stability in harsh industrial settings; Circuit breaker back-up; Metal-embossed date and catalog number for traceability and lasting identification; Time-delay for motor starting and transformer inrush; Small footprint requires less mounting space and allows smaller, more economical fuse blocks; Easy 2-to-1 selectivity for prevention of nuisance shutdowns; CSA certified to standard C22.2 No. 248.8
600V 250A CLASS J TD FUSE
Circuit breaker back-up; Easy 2-to-1 selectivity for prevention of nuisance shutdowns; DC listed to UL standard 248; Non-indicating or solid state SmartSpot visual blown fuse indicator; Feeders; Load centers; DC tested to UL standard 248; High-grade silica filler ensures fast arc quenching; Mains; Control panels; Lighting, heating & general loads; Unique Class J dimensions prevent replacement errors; Fiberglass body provides dimensional stability in harsh industrial settings; Branch circuits; UL listed to standard 248-8 File E2137; UL listed; Bus duct; Recommended for Arc Flash energy reduction; CSA certified to standard C22.2 No. 248.8; Extremely current-limiting for low peak let-thru current; Metal-embossed date and catalog number for traceability and lasting identification; Most current-limiting UL class fuse; Small footprint requires less mounting space and allows smaller, more economical fuse blocks; Optional EI indicator/switch mount for AJT70 to 600 open fuse indication; Transformers; High-visibility orange label gives instant brand recognition; 300kA interrupting rating – self-certified, UL witnessed tests; Motor circuits; Time-delay for motor starting and transformer inrush; IEC 60269-2-1
600V 300A CLASS J TD FUSE
Unique Class J dimensions prevent replacement errors; Time-delay for motor starting and transformer inrush; Small footprint requires less mounting space and allows smaller, more economical fuse blocks; Circuit breaker back-up; Bus duct; CSA certified to standard C22.2 No. 248.8; High-grade silica filler ensures fast arc quenching; Feeders; Fiberglass body provides dimensional stability in harsh industrial settings; High-visibility orange label gives instant brand recognition; Mains; DC tested to UL standard 248; Extremely current-limiting for low peak let-thru current; Easy 2-to-1 selectivity for prevention of nuisance shutdowns; Control panels; Load centers; Recommended for Arc Flash energy reduction; Metal-embossed date and catalog number for traceability and lasting identification; Lighting, heating & general loads; IEC 60269-2-1; Branch circuits; DC listed to UL standard 248; Motor circuits; Transformers; UL listed to standard 248-8 File E2137; 300kA interrupting rating – self-certified, UL witnessed tests; Optional EI indicator/switch mount for AJT70 to 600 open fuse indication; Non-indicating or solid state SmartSpot visual blown fuse indicator; UL listed; Most current-limiting UL class fuse
J TD FUSE 600V 300A AJT EI
Extremely current-limiting for low peak let-thru current; Feeders; High-grade silica filler ensures fast arc quenching; Small footprint requires less mounting space and allows smaller, more economical fuse blocks; Motor circuits; UL listed; UL listed to standard 248-8 File E2137; Load centers; High-visibility orange label gives instant brand recognition; CSA certified to standard C22.2 No. 248.8; Unique Class J dimensions prevent replacement errors; Time-delay for motor starting and transformer inrush; Metal-embossed date and catalog number for traceability and lasting identification; Most current-limiting UL class fuse; Non-indicating or solid state SmartSpot visual blown fuse indicator; Fiberglass body provides dimensional stability in harsh industrial settings; Mains; IEC 60269-2-1; Easy 2-to-1 selectivity for prevention of nuisance shutdowns; Transformers; DC tested to UL standard 248; Control panels; Recommended for Arc Flash energy reduction; Lighting, heating & general loads; DC listed to UL standard 248; 300kA interrupting rating – self-certified, UL witnessed tests; Branch circuits; Bus duct; Optional EI indicator/switch mount for AJT70 to 600 open fuse indication; Circuit breaker back-up