Browse Categories

Search in Category

Fuses

Search Filters

  • 2.88 in x

Filter Your Search

Shop by Category

Loading...

Fuses

Power Products/Fuses 
Viewing Page 1 of 6 (53 results)
900A 500V SEMICOND FUSE

900A 500V SEMICOND FUSE

Item #: A50QS900-4

Supplier Part #: A50QS900-4
Brand: Mersen

A50QS Amp-Trap® Form 101 fuses grew out of the need to improve the overall performance of semiconductor fuses in response to new equipment requirements. The A50QS encompasses the best protection features – lower I2t to provide better protection for equipment, longer life when subjected to cyclic loading and lower watts loss. A50QS is today’s best choice for the protection of dynamic solid state equipment such as motor drives, inverters, UPS, etc.

CSA Certified LR12636; State-of-the-art protection for 500V equipment; DC Tested to UL standard 198L parameters (70-1200A); Ultra compact sizes allow down-sizing of existing equipment; Superior cycling ability gives an equipment design advantage; UL recognized component UL File 60314; Lowest I2t for greatest protection of semiconductor circuits; AC: UL guide no. JFHR2; Low watts loss for cooler operation

$822.17 /EA
NOT CURRENTLY IN STOCK
1000A 500V SEMICOND FUSE

1000A 500V SEMICOND FUSE

Item #: A50QS1000-4

Supplier Part #: A50QS1000-4
Brand: Mersen

A50QS Amp-Trap® Form 101 fuses grew out of the need to improve the overall performance of semiconductor fuses in response to new equipment requirements. The A50QS encompasses the best protection features – lower I2t to provide better protection for equipment, longer life when subjected to cyclic loading and lower watts loss. A50QS is today’s best choice for the protection of dynamic solid state equipment such as motor drives, inverters, UPS, etc.

CSA Certified LR12636; AC: UL guide no. JFHR2; Ultra compact sizes allow down-sizing of existing equipment; Superior cycling ability gives an equipment design advantage; DC Tested to UL standard 198L parameters (70-1200A); Low watts loss for cooler operation; State-of-the-art protection for 500V equipment; UL recognized component UL File 60314; Lowest I2t for greatest protection of semiconductor circuits

$914.50 /EA
NOT CURRENTLY IN STOCK
1200A 500V SEMICOND FUSE

1200A 500V SEMICOND FUSE

Item #: A50QS1200-4

Supplier Part #: A50QS1200-4
Brand: Mersen

A50QS Amp-Trap® Form 101 fuses grew out of the need to improve the overall performance of semiconductor fuses in response to new equipment requirements. The A50QS encompasses the best protection features – lower I2t to provide better protection for equipment, longer life when subjected to cyclic loading and lower watts loss. A50QS is today’s best choice for the protection of dynamic solid state equipment such as motor drives, inverters, UPS, etc.

State-of-the-art protection for 500V equipment; Lowest I2t for greatest protection of semiconductor circuits; Low watts loss for cooler operation; AC: UL guide no. JFHR2; CSA Certified LR12636; DC Tested to UL standard 198L parameters (70-1200A); Superior cycling ability gives an equipment design advantage; Ultra compact sizes allow down-sizing of existing equipment; UL recognized component UL File 60314

$914.50 /EA
NOT CURRENTLY IN STOCK
3.3KV,442mm,3DIA,MV FUSE 3R

3.3KV,442mm,3DIA,MV FUSE 3R

Item #: A033D1DSR0-3R

Supplier Part #: A033D1DSR0-3R
Brand: Mersen

Amp-Trap® R-Rated DIN style fuses are current-limiting, high interrupting rating fuses, intended for the short circuit protection of medium voltage motors and motor controllers. This product range offers North American R-Rated performance in the IEC 282-1 DIN mounting configuration of 442mm. R-Rated fuses are applied as back up fuses that have a minimum interrupting rating, and must be coordinated with overload relays in combination motor starters. Amp-Trap R-Rated, DIN type fuses are offered in voltage ratings of 3.3kV, 5.3kV and 7.2kV in ratings from 2R to 19R. All fuses within this product group are UL component recognized. DEFINITIONS ,R-Rating R-Rated fuses are back-up fuses that operate as follows (Per ANSI C37.46-2000) An R-Rated fuse will melt in the range of 15 to 35 seconds at a value of current equal to 100 times the “R” rating ,Back-up Current-Limiting Fuses A back-up current-limiting fuse is a fuse that can interrupt any current between its rated minimum interrupting current and its maximum interrupting current. Back-up fuses are not designed or intended to open under overload conditions ,Continuous Ampere Rating at 40°C The continuous amp rating defines the thermal capability of the fuse per ANSI C37.46 and should not be the sole factor in fuse selection ,Spring-Reinforced Clip MR45 & Spring Ref.# L096472 ,Fuse-Holder SI 24/442 Ref # K209424 In compliance with IEC 282-1, DIN standard 43625 ,Note Ratings above 19R may be achieved by paralleling fuses. Please consult factory for details

Current-limiting for superior equipment protection; Blown fuse indicator provides positive identification of open fuse. 4.5lb tripping force – 1.0”; UL recognized component File E93367

$862.50 /EA
NOT CURRENTLY IN STOCK
5.5KV,442mm,3DIA,MV FUSE 16R

5.5KV,442mm,3DIA,MV FUSE 16R

Item #: A055D1DSR0-16R

Supplier Part #: A055D1DSR0-16R
Brand: Mersen

Amp-Trap® R-Rated DIN style fuses are current-limiting, high interrupting rating fuses, intended for the short circuit protection of medium voltage motors and motor controllers. This product range offers North American R-Rated performance in the IEC 282-1 DIN mounting configuration of 442mm. R-Rated fuses are applied as back up fuses that have a minimum interrupting rating, and must be coordinated with overload relays in combination motor starters. Amp-Trap R-Rated, DIN type fuses are offered in voltage ratings of 3.3kV, 5.3kV and 7.2kV in ratings from 2R to 19R. All fuses within this product group are UL component recognized. DEFINITIONS ,R-Rating R-Rated fuses are back-up fuses that operate as follows (Per ANSI C37.46-2000) An R-Rated fuse will melt in the range of 15 to 35 seconds at a value of current equal to 100 times the “R” rating ,Back-up Current-Limiting Fuses A back-up current-limiting fuse is a fuse that can interrupt any current between its rated minimum interrupting current and its maximum interrupting current. Back-up fuses are not designed or intended to open under overload conditions ,Continuous Ampere Rating at 40°C The continuous amp rating defines the thermal capability of the fuse per ANSI C37.46 and should not be the sole factor in fuse selection ,Spring-Reinforced Clip MR45 & Spring Ref.# L096472 ,Fuse-Holder SI 24/442 Ref # K209424 In compliance with IEC 282-1, DIN standard 43625 ,Note Ratings above 19R may be achieved by paralleling fuses. Please consult factory for details

UL recognized component File E93367; Current-limiting for superior equipment protection; Blown fuse indicator provides positive identification of open fuse. 4.5lb tripping force – 1.0”

$1,355.40 /EA
NOT CURRENTLY IN STOCK
5.5KV,442mm,3DIA,MV FUSE 19R

5.5KV,442mm,3DIA,MV FUSE 19R

Item #: A055D1DSR0-19R

Supplier Part #: A055D1DSR0-19R
Brand: Mersen

Amp-Trap® R-Rated DIN style fuses are current-limiting, high interrupting rating fuses, intended for the short circuit protection of medium voltage motors and motor controllers. This product range offers North American R-Rated performance in the IEC 282-1 DIN mounting configuration of 442mm. R-Rated fuses are applied as back up fuses that have a minimum interrupting rating, and must be coordinated with overload relays in combination motor starters. Amp-Trap R-Rated, DIN type fuses are offered in voltage ratings of 3.3kV, 5.3kV and 7.2kV in ratings from 2R to 19R. All fuses within this product group are UL component recognized. DEFINITIONS ,R-Rating R-Rated fuses are back-up fuses that operate as follows (Per ANSI C37.46-2000) An R-Rated fuse will melt in the range of 15 to 35 seconds at a value of current equal to 100 times the “R” rating ,Back-up Current-Limiting Fuses A back-up current-limiting fuse is a fuse that can interrupt any current between its rated minimum interrupting current and its maximum interrupting current. Back-up fuses are not designed or intended to open under overload conditions ,Continuous Ampere Rating at 40°C The continuous amp rating defines the thermal capability of the fuse per ANSI C37.46 and should not be the sole factor in fuse selection ,Spring-Reinforced Clip MR45 & Spring Ref.# L096472 ,Fuse-Holder SI 24/442 Ref # K209424 In compliance with IEC 282-1, DIN standard 43625 ,Note Ratings above 19R may be achieved by paralleling fuses. Please consult factory for details

Blown fuse indicator provides positive identification of open fuse. 4.5lb tripping force – 1.0”; UL recognized component File E93367; Current-limiting for superior equipment protection

$1,355.40 /EA
NOT CURRENTLY IN STOCK
5.5KV,442mm,3DIA,MV FUSE 2R

5.5KV,442mm,3DIA,MV FUSE 2R

Item #: A055D1DSR0-2R

Supplier Part #: A055D1DSR0-2R
Brand: Mersen

Amp-Trap® R-Rated DIN style fuses are current-limiting, high interrupting rating fuses, intended for the short circuit protection of medium voltage motors and motor controllers. This product range offers North American R-Rated performance in the IEC 282-1 DIN mounting configuration of 442mm. R-Rated fuses are applied as back up fuses that have a minimum interrupting rating, and must be coordinated with overload relays in combination motor starters. Amp-Trap R-Rated, DIN type fuses are offered in voltage ratings of 3.3kV, 5.3kV and 7.2kV in ratings from 2R to 19R. All fuses within this product group are UL component recognized. DEFINITIONS ,R-Rating R-Rated fuses are back-up fuses that operate as follows (Per ANSI C37.46-2000) An R-Rated fuse will melt in the range of 15 to 35 seconds at a value of current equal to 100 times the “R” rating ,Back-up Current-Limiting Fuses A back-up current-limiting fuse is a fuse that can interrupt any current between its rated minimum interrupting current and its maximum interrupting current. Back-up fuses are not designed or intended to open under overload conditions ,Continuous Ampere Rating at 40°C The continuous amp rating defines the thermal capability of the fuse per ANSI C37.46 and should not be the sole factor in fuse selection ,Spring-Reinforced Clip MR45 & Spring Ref.# L096472 ,Fuse-Holder SI 24/442 Ref # K209424 In compliance with IEC 282-1, DIN standard 43625 ,Note Ratings above 19R may be achieved by paralleling fuses. Please consult factory for details

Current-limiting for superior equipment protection; Blown fuse indicator provides positive identification of open fuse. 4.5lb tripping force – 1.0”; UL recognized component File E93367

$928.86 /EA
NOT CURRENTLY IN STOCK
5.5KV,442mm,3DIA,MV FUSE 3R

5.5KV,442mm,3DIA,MV FUSE 3R

Item #: A055D1DSR0-3R

Supplier Part #: A055D1DSR0-3R
Brand: Mersen

Amp-Trap® R-Rated DIN style fuses are current-limiting, high interrupting rating fuses, intended for the short circuit protection of medium voltage motors and motor controllers. This product range offers North American R-Rated performance in the IEC 282-1 DIN mounting configuration of 442mm. R-Rated fuses are applied as back up fuses that have a minimum interrupting rating, and must be coordinated with overload relays in combination motor starters. Amp-Trap R-Rated, DIN type fuses are offered in voltage ratings of 3.3kV, 5.3kV and 7.2kV in ratings from 2R to 19R. All fuses within this product group are UL component recognized. DEFINITIONS ,R-Rating R-Rated fuses are back-up fuses that operate as follows (Per ANSI C37.46-2000) An R-Rated fuse will melt in the range of 15 to 35 seconds at a value of current equal to 100 times the “R” rating ,Back-up Current-Limiting Fuses A back-up current-limiting fuse is a fuse that can interrupt any current between its rated minimum interrupting current and its maximum interrupting current. Back-up fuses are not designed or intended to open under overload conditions ,Continuous Ampere Rating at 40°C The continuous amp rating defines the thermal capability of the fuse per ANSI C37.46 and should not be the sole factor in fuse selection ,Spring-Reinforced Clip MR45 & Spring Ref.# L096472 ,Fuse-Holder SI 24/442 Ref # K209424 In compliance with IEC 282-1, DIN standard 43625 ,Note Ratings above 19R may be achieved by paralleling fuses. Please consult factory for details

Blown fuse indicator provides positive identification of open fuse. 4.5lb tripping force – 1.0”; UL recognized component File E93367; Current-limiting for superior equipment protection

$928.86 /EA
NOT CURRENTLY IN STOCK
7.2KV,442mm,3DIA,MV FUSE 2R

7.2KV,442mm,3DIA,MV FUSE 2R

Item #: A072D1DSR0-2R

Supplier Part #: A072D1DSR0-2R
Brand: Mersen

Amp-Trap® R-Rated DIN style fuses are current-limiting, high interrupting rating fuses, intended for the short circuit protection of medium voltage motors and motor controllers. This product range offers North American R-Rated performance in the IEC 282-1 DIN mounting configuration of 442mm. R-Rated fuses are applied as back up fuses that have a minimum interrupting rating, and must be coordinated with overload relays in combination motor starters. Amp-Trap R-Rated, DIN type fuses are offered in voltage ratings of 3.3kV, 5.3kV and 7.2kV in ratings from 2R to 19R. All fuses within this product group are UL component recognized. DEFINITIONS ,R-Rating R-Rated fuses are back-up fuses that operate as follows (Per ANSI C37.46-2000) An R-Rated fuse will melt in the range of 15 to 35 seconds at a value of current equal to 100 times the “R” rating ,Back-up Current-Limiting Fuses A back-up current-limiting fuse is a fuse that can interrupt any current between its rated minimum interrupting current and its maximum interrupting current. Back-up fuses are not designed or intended to open under overload conditions ,Continuous Ampere Rating at 40°C The continuous amp rating defines the thermal capability of the fuse per ANSI C37.46 and should not be the sole factor in fuse selection ,Spring-Reinforced Clip MR45 & Spring Ref.# L096472 ,Fuse-Holder SI 24/442 Ref # K209424 In compliance with IEC 282-1, DIN standard 43625 ,Note Ratings above 19R may be achieved by paralleling fuses. Please consult factory for details

Blown fuse indicator provides positive identification of open fuse. 4.5lb tripping force – 1.0”; UL recognized component File E93367; Current-limiting for superior equipment protection

$1,239.71 /EA
NOT CURRENTLY IN STOCK
7.2KV,442mm,3DIA,MV FUSE 3R

7.2KV,442mm,3DIA,MV FUSE 3R

Item #: A072D1DSR0-3R

Supplier Part #: A072D1DSR0-3R
Brand: Mersen

Amp-Trap® R-Rated DIN style fuses are current-limiting, high interrupting rating fuses, intended for the short circuit protection of medium voltage motors and motor controllers. This product range offers North American R-Rated performance in the IEC 282-1 DIN mounting configuration of 442mm. R-Rated fuses are applied as back up fuses that have a minimum interrupting rating, and must be coordinated with overload relays in combination motor starters. Amp-Trap R-Rated, DIN type fuses are offered in voltage ratings of 3.3kV, 5.3kV and 7.2kV in ratings from 2R to 19R. All fuses within this product group are UL component recognized. DEFINITIONS ,R-Rating R-Rated fuses are back-up fuses that operate as follows (Per ANSI C37.46-2000) An R-Rated fuse will melt in the range of 15 to 35 seconds at a value of current equal to 100 times the “R” rating ,Back-up Current-Limiting Fuses A back-up current-limiting fuse is a fuse that can interrupt any current between its rated minimum interrupting current and its maximum interrupting current. Back-up fuses are not designed or intended to open under overload conditions ,Continuous Ampere Rating at 40°C The continuous amp rating defines the thermal capability of the fuse per ANSI C37.46 and should not be the sole factor in fuse selection ,Spring-Reinforced Clip MR45 & Spring Ref.# L096472 ,Fuse-Holder SI 24/442 Ref # K209424 In compliance with IEC 282-1, DIN standard 43625 ,Note Ratings above 19R may be achieved by paralleling fuses. Please consult factory for details

Current-limiting for superior equipment protection; Blown fuse indicator provides positive identification of open fuse. 4.5lb tripping force – 1.0”; UL recognized component File E93367

$1,239.71 /EA
NOT CURRENTLY IN STOCK
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • NEXT »