Search in Category
Search Filters
-
19.3 lb x
Filter Your Search
Shop by Category
Fuses
600V, 2501A, CLASS L, TD FUSE
UL listed; 300kA interrupting rating – self-certified, UL witnessed tests; Fiberglass body provides dimensional stability in harsh industrial settings; Large motors; Metal-embossed date and catalog number for traceability and lasting identification; CSA certified to standard C22.2 No. 248.10 (601-6000A); Mains; Circuit breaker back-up; Recommended for Arc Flash energy reduction; Reduced inventory because A4BQ can replace all older types of Class L fuses now in-service; Pure silver links ensure lowest let-thru current and longer fuse life; Rejection-style design prevents replacement errors; Fastest operation under short circuit conditions: Let-thru currents are typically 20 percent lower, with a corresponding let-thru energy (clearing I2t) up to 40% lower than the next fastest Class L fuse; High-visibility orange label gives instant brand recognition; High-grade silica filler ensures fast arc quenching; Most current-limiting for lowest peak let-thru current; even at fault currents up to 300kA; DC listed to UL standard 248 (100-2000A); UL listed to standard 248-10 File E2137; Feeders; Time-delay for high inrush loads such as motors and transformers, without nuisance opening; Easy 2-to-1 selectivity for prevention of nuisance shutdowns and “blackouts”; Optional mechanical TA indicator (100-6000A). Please contact factory for special trigger actuator; Lighting, heating & general loads
L TD FUSE 600V 3000A A4BQ
Rejection-style design prevents replacement errors; Metal-embossed date and catalog number for traceability and lasting identification; High-visibility orange label gives instant brand recognition; Feeders; Mains; Fastest operation under short circuit conditions: Let-thru currents are typically 20 percent lower, with a corresponding let-thru energy (clearing I2t) up to 40% lower than the next fastest Class L fuse; 300kA interrupting rating – self-certified, UL witnessed tests; Most current-limiting for lowest peak let-thru current; even at fault currents up to 300kA; High-grade silica filler ensures fast arc quenching; Recommended for Arc Flash energy reduction; Easy 2-to-1 selectivity for prevention of nuisance shutdowns and “blackouts”; Fiberglass body provides dimensional stability in harsh industrial settings; Reduced inventory because A4BQ can replace all older types of Class L fuses now in-service; Pure silver links ensure lowest let-thru current and longer fuse life; UL listed; CSA certified to standard C22.2 No. 248.10 (601-6000A); Large motors; UL listed to standard 248-10 File E2137; Lighting, heating & general loads; Time-delay for high inrush loads such as motors and transformers, without nuisance opening; Optional mechanical TA indicator (100-6000A). Please contact factory for special trigger actuator; DC listed to UL standard 248 (100-2000A); Circuit breaker back-up
93962-FUSE,FORM 480
DC Tested to UL 248 limits (Mersen Self-Certified); Blade-stamped catalog numbers for permanent identification; Feeders; Circuit Breakers; Metering Centers; Unique dimensions prevent replacement by other fuse classes; Mains; CSA Certified to Standard C22.2, No. 248.10 IEC 269-2-1; Mersen Self-Certification, UL Listed to Standard 248-10, File E2137; Panelboards; Switchboards; Glass melamine body and plated terminals provide superior reliability in harsh environments; Load centers
L TD FUSE 600V 3000A A4BY
CSA Certified to Standard C22.2, No. 248.10 IEC 269-2-1; Unique dimensions prevent replacement by other fuse classes; Mersen Self-Certification, UL Listed to Standard 248-10, File E2137; DC Tested to UL 248 limits (Mersen Self-Certified); Circuit Breakers; Mains; Blade-stamped catalog numbers for permanent identification; Load centers; Panelboards; Switchboards; Glass melamine body and plated terminals provide superior reliability in harsh environments; Feeders; Metering Centers