J TD FUSE 600V 150A AJT

J TD FUSE 600V 150A AJT

Item #: AJT150

Supplier Part #: AJT150
Brand: Mersen

Amp-Trap 2000® AJT fuses provide non-indication as well as a SmartSpot visual open fuse indicator. With advanced material technology the AJT fuse provides IEC Type 2 No Damage protection to main, feeder, and branch circuits, for all types of loads — yet, they require only half the mounting space needed for 600VAC Class RK fuses. AJT’s time-delay characteristics are ideal for handling typical motor and transformer inrush currents, while also providing superior current-limiting ability.

Transformers; CSA certified to standard C22.2 No. 248.8; High-grade silica filler ensures fast arc quenching; Fiberglass body provides dimensional stability in harsh industrial settings; Extremely current-limiting for low peak let-thru current; Load centers; Non-indicating or solid state SmartSpot visual blown fuse indicator; Small footprint requires less mounting space and allows smaller, more economical fuse blocks; High-visibility orange label gives instant brand recognition; Bus duct; Metal-embossed date and catalog number for traceability and lasting identification; Control panels; Motor circuits; 300kA interrupting rating – self-certified, UL witnessed tests; Branch circuits; Recommended for Arc Flash energy reduction; Lighting, heating & general loads; IEC 60269-2-1; DC tested to UL standard 248; UL listed; Mains; Feeders; Time-delay for motor starting and transformer inrush; Unique Class J dimensions prevent replacement errors; DC listed to UL standard 248; Circuit breaker back-up; UL listed to standard 248-8 File E2137; Easy 2-to-1 selectivity for prevention of nuisance shutdowns; Most current-limiting UL class fuse; Optional EI indicator/switch mount for AJT70 to 600 open fuse indication

$277.42 /EA
NOT CURRENTLY IN STOCK
600V 125A CLASS J TD FUSE

600V 125A CLASS J TD FUSE

Item #: AJT125

Supplier Part #: AJT125
Brand: Mersen

Amp-Trap 2000® AJT fuses provide non-indication as well as a SmartSpot visual open fuse indicator. With advanced material technology the AJT fuse provides IEC Type 2 No Damage protection to main, feeder, and branch circuits, for all types of loads — yet, they require only half the mounting space needed for 600VAC Class RK fuses. AJT’s time-delay characteristics are ideal for handling typical motor and transformer inrush currents, while also providing superior current-limiting ability.

Recommended for Arc Flash energy reduction; Non-indicating or solid state SmartSpot visual blown fuse indicator; Load centers; CSA certified to standard C22.2 No. 248.8; Lighting, heating & general loads; Feeders; Bus duct; Circuit breaker back-up; Extremely current-limiting for low peak let-thru current; Optional EI indicator/switch mount for AJT70 to 600 open fuse indication; Transformers; Unique Class J dimensions prevent replacement errors; Motor circuits; High-grade silica filler ensures fast arc quenching; UL listed; Mains; 300kA interrupting rating – self-certified, UL witnessed tests; IEC 60269-2-1; Most current-limiting UL class fuse; DC tested to UL standard 248; Metal-embossed date and catalog number for traceability and lasting identification; High-visibility orange label gives instant brand recognition; Fiberglass body provides dimensional stability in harsh industrial settings; DC listed to UL standard 248; Small footprint requires less mounting space and allows smaller, more economical fuse blocks; UL listed to standard 248-8 File E2137; Time-delay for motor starting and transformer inrush; Easy 2-to-1 selectivity for prevention of nuisance shutdowns; Branch circuits; Control panels

$277.42 /EA
NOT CURRENTLY IN STOCK
J TD FUSE 600V 200A AJT

J TD FUSE 600V 200A AJT

Item #: AJT200

Supplier Part #: AJT200
Brand: Mersen

Amp-Trap 2000® AJT fuses provide non-indication as well as a SmartSpot visual open fuse indicator. With advanced material technology the AJT fuse provides IEC Type 2 No Damage protection to main, feeder, and branch circuits, for all types of loads — yet, they require only half the mounting space needed for 600VAC Class RK fuses. AJT’s time-delay characteristics are ideal for handling typical motor and transformer inrush currents, while also providing superior current-limiting ability.

300kA interrupting rating – self-certified, UL witnessed tests; Load centers; Small footprint requires less mounting space and allows smaller, more economical fuse blocks; Bus duct; Circuit breaker back-up; Branch circuits; Control panels; DC listed to UL standard 248; CSA certified to standard C22.2 No. 248.8; Easy 2-to-1 selectivity for prevention of nuisance shutdowns; High-grade silica filler ensures fast arc quenching; DC tested to UL standard 248; Recommended for Arc Flash energy reduction; Unique Class J dimensions prevent replacement errors; Motor circuits; Most current-limiting UL class fuse; Feeders; High-visibility orange label gives instant brand recognition; Metal-embossed date and catalog number for traceability and lasting identification; IEC 60269-2-1; Optional EI indicator/switch mount for AJT70 to 600 open fuse indication; UL listed; Time-delay for motor starting and transformer inrush; Fiberglass body provides dimensional stability in harsh industrial settings; Mains; Lighting, heating & general loads; Transformers; UL listed to standard 248-8 File E2137; Extremely current-limiting for low peak let-thru current; Non-indicating or solid state SmartSpot visual blown fuse indicator

$277.42 /EA
NOT CURRENTLY IN STOCK
J FUSE 600V 110A A4J EI

J FUSE 600V 110A A4J EI

Item #: A4J110EI

Supplier Part #: A4J110EI
Brand: Mersen

Amp-Trap fast-acting A4J fuses deliver excellent current-limiting protection to a wide variety of applications. Their unique dimensions prevent the substitution of other fuses with lower voltage ratings, interrupting ratings, or current-limiting capability.

Panelboards; Unique dimensions prevent replacement by other fuse classes; Lighting, heating, and general loads; Switchboards; Fiberglass body provides dimensional stability in harsh industrial environments; Load centers; UL listed to standard 248-8 File E2137; Capacitors; Easy-to-read imprint label for quick recognition and replacement; Bus duct; Feeder circuits; Circuit breakers; CSA certified to standard C22.2 no. 248.8; DC listed to UL 248; High current limitation for low peak let-thru current; IEC 269-2-1

$319.82 /EA
NOT CURRENTLY IN STOCK
J FUSE 600V 200A A4J EI

J FUSE 600V 200A A4J EI

Item #: A4J200EI

Supplier Part #: A4J200EI
Brand: Mersen

Amp-Trap fast-acting A4J fuses deliver excellent current-limiting protection to a wide variety of applications. Their unique dimensions prevent the substitution of other fuses with lower voltage ratings, interrupting ratings, or current-limiting capability.

Feeder circuits; High current limitation for low peak let-thru current; CSA certified to standard C22.2 no. 248.8; IEC 269-2-1; Circuit breakers; Unique dimensions prevent replacement by other fuse classes; Easy-to-read imprint label for quick recognition and replacement; Panelboards; Capacitors; Load centers; Lighting, heating, and general loads; Bus duct; DC listed to UL 248; Fiberglass body provides dimensional stability in harsh industrial environments; UL listed to standard 248-8 File E2137; Switchboards

$278.09 /EA
NOT CURRENTLY IN STOCK
600V 110A CLASS J TD FUSE

600V 110A CLASS J TD FUSE

Item #: AJT110

Brand: Mersen

Amp-Trap 2000® AJT fuses provide non-indication as well as a SmartSpot visual open fuse indicator. With advanced material technology the AJT fuse provides IEC Type 2 No Damage protection to main, feeder, and branch circuits, for all types of loads — yet, they require only half the mounting space needed for 600VAC Class RK fuses. AJT’s time-delay characteristics are ideal for handling typical motor and transformer inrush currents, while also providing superior current-limiting ability.

DC listed to UL standard 248; UL listed; Lighting, heating & general loads; 300kA interrupting rating – self-certified, UL witnessed tests; Motor circuits; Recommended for Arc Flash energy reduction; DC tested to UL standard 248; Control panels; Branch circuits; Extremely current-limiting for low peak let-thru current; High-grade silica filler ensures fast arc quenching; IEC 60269-2-1; Time-delay for motor starting and transformer inrush; High-visibility orange label gives instant brand recognition; Transformers; Unique Class J dimensions prevent replacement errors; Most current-limiting UL class fuse; UL listed to standard 248-8 File E2137; Optional EI indicator/switch mount for AJT70 to 600 open fuse indication; Small footprint requires less mounting space and allows smaller, more economical fuse blocks; Feeders; Fiberglass body provides dimensional stability in harsh industrial settings; CSA certified to standard C22.2 No. 248.8; Non-indicating or solid state SmartSpot visual blown fuse indicator; Easy 2-to-1 selectivity for prevention of nuisance shutdowns; Circuit breaker back-up; Load centers; Mains; Metal-embossed date and catalog number for traceability and lasting identification; Bus duct

$275.17 /EA
NOT CURRENTLY IN STOCK
600V 175A CLASS J TD FUSE

600V 175A CLASS J TD FUSE

Item #: AJT175

Supplier Part #: AJT175
Brand: Mersen

Amp-Trap 2000® AJT fuses provide non-indication as well as a SmartSpot visual open fuse indicator. With advanced material technology the AJT fuse provides IEC Type 2 No Damage protection to main, feeder, and branch circuits, for all types of loads — yet, they require only half the mounting space needed for 600VAC Class RK fuses. AJT’s time-delay characteristics are ideal for handling typical motor and transformer inrush currents, while also providing superior current-limiting ability.

Mains; IEC 60269-2-1; High-visibility orange label gives instant brand recognition; High-grade silica filler ensures fast arc quenching; Most current-limiting UL class fuse; UL listed; CSA certified to standard C22.2 No. 248.8; Extremely current-limiting for low peak let-thru current; Lighting, heating & general loads; Branch circuits; Load centers; Non-indicating or solid state SmartSpot visual blown fuse indicator; Motor circuits; Control panels; Time-delay for motor starting and transformer inrush; 300kA interrupting rating – self-certified, UL witnessed tests; DC listed to UL standard 248; Recommended for Arc Flash energy reduction; Feeders; Metal-embossed date and catalog number for traceability and lasting identification; UL listed to standard 248-8 File E2137; Circuit breaker back-up; Optional EI indicator/switch mount for AJT70 to 600 open fuse indication; Bus duct; Fiberglass body provides dimensional stability in harsh industrial settings; Small footprint requires less mounting space and allows smaller, more economical fuse blocks; Unique Class J dimensions prevent replacement errors; Transformers; DC tested to UL standard 248; Easy 2-to-1 selectivity for prevention of nuisance shutdowns

$275.17 /EA
NOT CURRENTLY IN STOCK
600V 200A  J TD NON-IND

600V 200A J TD NON-IND

Item #: AJT200N

Supplier Part #: AJT200N
Brand: Mersen

Amp-Trap 2000® AJT fuses provide non-indication as well as a SmartSpot visual open fuse indicator. With advanced material technology the AJT fuse provides IEC Type 2 No Damage protection to main, feeder, and branch circuits, for all types of loads — yet, they require only half the mounting space needed for 600VAC Class RK fuses. AJT’s time-delay characteristics are ideal for handling typical motor and transformer inrush currents, while also providing superior current-limiting ability.

UL listed; Branch circuits; Recommended for Arc Flash energy reduction; Fiberglass body provides dimensional stability in harsh industrial settings; Motor circuits; Lighting, heating & general loads; 300kA interrupting rating – self-certified, UL witnessed tests; Unique Class J dimensions prevent replacement errors; Non-indicating or solid state SmartSpot visual blown fuse indicator; Control panels; Small footprint requires less mounting space and allows smaller, more economical fuse blocks; DC listed to UL standard 248; UL listed to standard 248-8 File E2137; Transformers; Extremely current-limiting for low peak let-thru current; Most current-limiting UL class fuse; Bus duct; Mains; CSA certified to standard C22.2 No. 248.8; High-grade silica filler ensures fast arc quenching; High-visibility orange label gives instant brand recognition; IEC 60269-2-1; Load centers; Time-delay for motor starting and transformer inrush; Circuit breaker back-up; Metal-embossed date and catalog number for traceability and lasting identification; Optional EI indicator/switch mount for AJT70 to 600 open fuse indication; DC tested to UL standard 248; Easy 2-to-1 selectivity for prevention of nuisance shutdowns; Feeders

$244.69 /EA
NOT CURRENTLY IN STOCK