Browse Categories

Search in Category

Fuses

Search Filters

  • 0.65 lb x

Filter Your Search

Show Attribute Brand

Shop by Category

Loading...

Fuses

Power Products/Fuses 
Viewing Page 1 of 1 (4 results)
600V 80A RK1 TD FUSE

600V 80A RK1 TD FUSE

Item #: A6D80R

Supplier Part #: A6D80R
Brand: Mersen

Amp-Trap 2000® SmartSpot time-delay A6D-R fuses provide IEC Type 2 "no damage" protection to existing mains, feeders, and branch circuits serving motor and non-motor loads. A6D-R fuses will open fast enough under extreme fault conditions for maximum short circuit protection to prevent damage to motor starters, switches, and other circuit components, yet also provide the time-delay needed for motor in-rush currents. A6D-R fuses can be used to replace older 600V Class H, K or RK5 fuses already installed in the field.

Safety switches; All general-purpose circuits; Time-delay for motor starting and transformer inrush currents without nuisance opening; DC listed to UL standard 248; Recommended for Arc Flash energy reduction; Branch circuit protection; Easy 2-to-1 selectivity for prevention of nuisance shut downs and “black outs”; Motors; Rejection-style design prevents replacement errors (when used with recommended fuse blocks); Extremely current-limiting for low peak let-thru current; Metal-embossed date and catalog number for easier traceability and lasting identification; Fiberglass body provides dimensional stability in harsh industrial settings; Transformers; UL listed to standard 248-12 File E2137; CSA certified to standard C22.2 No. 248.12; Solid state SmartSpot visual blown fuse indicator; Disconnects; 300kA interrupting rating – self-certified, UL witnessed tests; High-visibility orange label gives instant brand recognition; Reduced inventory by taking the place of class RK5, K, and H fuses; 600VAC & 600VDC dual rated; Control panels

$123.47 /EA
NOT CURRENTLY IN STOCK
600V 70A RK1 TD FUSE

600V 70A RK1 TD FUSE

Item #: A6D70R

Supplier Part #: A6D70R
Brand: Mersen

Amp-Trap 2000® SmartSpot time-delay A6D-R fuses provide IEC Type 2 "no damage" protection to existing mains, feeders, and branch circuits serving motor and non-motor loads. A6D-R fuses will open fast enough under extreme fault conditions for maximum short circuit protection to prevent damage to motor starters, switches, and other circuit components, yet also provide the time-delay needed for motor in-rush currents. A6D-R fuses can be used to replace older 600V Class H, K or RK5 fuses already installed in the field.

Transformers; Motors; Time-delay for motor starting and transformer inrush currents without nuisance opening; 300kA interrupting rating – self-certified, UL witnessed tests; Solid state SmartSpot visual blown fuse indicator; Fiberglass body provides dimensional stability in harsh industrial settings; Control panels; Extremely current-limiting for low peak let-thru current; Branch circuit protection; High-visibility orange label gives instant brand recognition; Disconnects; Recommended for Arc Flash energy reduction; Rejection-style design prevents replacement errors (when used with recommended fuse blocks); Metal-embossed date and catalog number for easier traceability and lasting identification; DC listed to UL standard 248; CSA certified to standard C22.2 No. 248.12; All general-purpose circuits; Safety switches; UL listed to standard 248-12 File E2137; Easy 2-to-1 selectivity for prevention of nuisance shut downs and “black outs”; Reduced inventory by taking the place of class RK5, K, and H fuses; 600VAC & 600VDC dual rated

$123.47 /EA
NOT CURRENTLY IN STOCK
600V 90A RK1 TD FUSE

600V 90A RK1 TD FUSE

Item #: A6D90R

Brand: Mersen

Amp-Trap 2000® SmartSpot time-delay A6D-R fuses provide IEC Type 2 "no damage" protection to existing mains, feeders, and branch circuits serving motor and non-motor loads. A6D-R fuses will open fast enough under extreme fault conditions for maximum short circuit protection to prevent damage to motor starters, switches, and other circuit components, yet also provide the time-delay needed for motor in-rush currents. A6D-R fuses can be used to replace older 600V Class H, K or RK5 fuses already installed in the field.

CSA certified to standard C22.2 No. 248.12; Solid state SmartSpot visual blown fuse indicator; 300kA interrupting rating – self-certified, UL witnessed tests; Control panels; High-visibility orange label gives instant brand recognition; Disconnects; Recommended for Arc Flash energy reduction; All general-purpose circuits; Metal-embossed date and catalog number for easier traceability and lasting identification; Transformers; Branch circuit protection; DC listed to UL standard 248; Fiberglass body provides dimensional stability in harsh industrial settings; 600VAC & 600VDC dual rated; Easy 2-to-1 selectivity for prevention of nuisance shut downs and “black outs”; UL listed to standard 248-12 File E2137; Rejection-style design prevents replacement errors (when used with recommended fuse blocks); Reduced inventory by taking the place of class RK5, K, and H fuses; Safety switches; Time-delay for motor starting and transformer inrush currents without nuisance opening; Motors; Extremely current-limiting for low peak let-thru current

$123.47 /EA
NOT CURRENTLY IN STOCK
600V 100A RK1 TD FUSE

600V 100A RK1 TD FUSE

Item #: A6D100R

Supplier Part #: A6D100R
Brand: Mersen

Amp-Trap 2000® SmartSpot time-delay A6D-R fuses provide IEC Type 2 "no damage" protection to existing mains, feeders, and branch circuits serving motor and non-motor loads. A6D-R fuses will open fast enough under extreme fault conditions for maximum short circuit protection to prevent damage to motor starters, switches, and other circuit components, yet also provide the time-delay needed for motor in-rush currents. A6D-R fuses can be used to replace older 600V Class H, K or RK5 fuses already installed in the field.

Rejection-style design prevents replacement errors (when used with recommended fuse blocks); 300kA interrupting rating – self-certified, UL witnessed tests; High-visibility orange label gives instant brand recognition; Safety switches; Branch circuit protection; Disconnects; Metal-embossed date and catalog number for easier traceability and lasting identification; 600VAC & 600VDC dual rated; DC listed to UL standard 248; Easy 2-to-1 selectivity for prevention of nuisance shut downs and “black outs”; All general-purpose circuits; CSA certified to standard C22.2 No. 248.12; Time-delay for motor starting and transformer inrush currents without nuisance opening; Transformers; Control panels; Recommended for Arc Flash energy reduction; UL listed to standard 248-12 File E2137; Solid state SmartSpot visual blown fuse indicator; Motors; Extremely current-limiting for low peak let-thru current; Reduced inventory by taking the place of class RK5, K, and H fuses; Fiberglass body provides dimensional stability in harsh industrial settings

$123.47 /EA
NOT CURRENTLY IN STOCK