6,9 URGL 36 / 355
H TD FUSE 250V 110A CRN
Type D fuses satisfy the Canadian Electrical Code requirement for low melting-point fuses; CSA Certified
H TD FUSE 250V 175A CRN
Type D fuses satisfy the Canadian Electrical Code requirement for low melting-point fuses; CSA Certified
250V 110A 7 1/8x1 9/10 K5FUSE
Easy to read imprint label for quick recognition and replacement; Residential and small commercial installations; UL Listed to Standard 248-9 File E2137; Feeders; Self-certified for DC per UL248; Low cost for high protection value; Resistive heating; CSA Certified to Standard C22.2 No. 248.9 (The Canadian Electrical Code requires these fuses in ratings 15 through 60A to be of the low melting point design; use OTN 15-60.); Branch circuits
250V 125A 7 1/8x1 9/10 K5FUSE
Residential and small commercial installations; Self-certified for DC per UL248; Branch circuits; Resistive heating; UL Listed to Standard 248-9 File E2137; Low cost for high protection value; Easy to read imprint label for quick recognition and replacement; Feeders; CSA Certified to Standard C22.2 No. 248.9 (The Canadian Electrical Code requires these fuses in ratings 15 through 60A to be of the low melting point design; use OTN 15-60.)
250V 150A 7 1/8x1 9/10 K5FUSE
Easy to read imprint label for quick recognition and replacement; CSA Certified to Standard C22.2 No. 248.9 (The Canadian Electrical Code requires these fuses in ratings 15 through 60A to be of the low melting point design; use OTN 15-60.); Branch circuits; Resistive heating; Residential and small commercial installations; Feeders; Low cost for high protection value; UL Listed to Standard 248-9 File E2137; Self-certified for DC per UL248
250V 175A 7 1/8x1 9/10 K5FUSE
Resistive heating; Low cost for high protection value; Residential and small commercial installations; Easy to read imprint label for quick recognition and replacement; UL Listed to Standard 248-9 File E2137; Feeders; CSA Certified to Standard C22.2 No. 248.9 (The Canadian Electrical Code requires these fuses in ratings 15 through 60A to be of the low melting point design; use OTN 15-60.); Branch circuits; Self-certified for DC per UL248
250V 200A 7 1/8x1 9/10 K5FUSE
CSA Certified to Standard C22.2 No. 248.9 (The Canadian Electrical Code requires these fuses in ratings 15 through 60A to be of the low melting point design; use OTN 15-60.); Resistive heating; Low cost for high protection value; UL Listed to Standard 248-9 File E2137; Residential and small commercial installations; Branch circuits; Self-certified for DC per UL248; Feeders; Easy to read imprint label for quick recognition and replacement
250V 110A 7 1/8x1 9/10 TD
Mains; Rejection-style design prevents replacement errors (when used with recommended fuse blocks); Easy-to-read label for quick brand recognition and replacement; Service entrance equipment; UL listed to standard 248-12 File E2137; High-grade silica filler ensures fast arc quenching and high current limitation; DC listed to UL standard 248 TRS only; Feeders; AC & DC rated; Optional solid state SmartSpot blown fuse indicator; Motor circuits; CSA certified to standard C22.2 no. 248.12; Metal-embossed date and catalog number for traceability and lasting identification; Transformers; Current-limiting; Time-delay for motor start-ups and transformer inrush currents without nuisance opening; General-purpose equipment; Branch circuits; Time-delay; Current-limiting for low peak let-thru current; Fiberglass body provides dimensional stability in harsh industrial settings
250V 175A 7 1/8x1 9/10 TD
Mains; Optional solid state SmartSpot blown fuse indicator; Transformers; AC & DC rated; Easy-to-read label for quick brand recognition and replacement; Metal-embossed date and catalog number for traceability and lasting identification; Time-delay; Motor circuits; High-grade silica filler ensures fast arc quenching and high current limitation; UL listed to standard 248-12 File E2137; Current-limiting for low peak let-thru current; General-purpose equipment; Fiberglass body provides dimensional stability in harsh industrial settings; Current-limiting; Rejection-style design prevents replacement errors (when used with recommended fuse blocks); DC listed to UL standard 248 TRS only; CSA certified to standard C22.2 no. 248.12; Feeders; Service entrance equipment; Branch circuits; Time-delay for motor start-ups and transformer inrush currents without nuisance opening