250V 110A RK1 TD FUSE

250V 110A RK1 TD FUSE

Item #: A2D110R

Supplier Part #: A2D110R
Brand: Mersen

Amp-Trap 2000 SmartSpot time-delay A2D-R fuses provide IEC Type 2 "no damage" protection to existing mains, feeders, and branch circuits serving motor and non-motor loads. A2D-R fuses will open fast enough under extreme fault conditions for maximum short circuit protection to prevent damage to motor starters, switches, and other circuit components, yet also provide the time-delay needed for motor in-rush currents. A2D-R fuses can be used to replace older 250V Class H, K or RK5 fuses already installed in the field.

Fiberglass body provides dimensional stability in harsh industrial settings; Motors; UL listed to standard 248-12 File E2137; 300kA interrupting rating – self-certified, UL witnessed tests; CSA certified to standard C22.2 No. 248.12; Transformers; Time-delay for motor starting and transformer inrush currents without nuisance opening; Extremely current-limiting for low peak let-thru current; Safety switches; Disconnects; 600VAC & 600VDC dual rated; Reduced inventory by taking the place of class RK5, K, and H fuses; Control panels; Solid state SmartSpot visual blown fuse indicator; DC listed to UL standard 248; Recommended for Arc Flash energy reduction; High-visibility orange label gives instant brand recognition; Rejection-style design prevents replacement errors (when used with recommended fuse blocks); Metal-embossed date and catalog number for easier traceability and lasting identification; Easy 2-to-1 selectivity for prevention of nuisance shut downs and “black outs”; All general-purpose circuits; Branch circuit protection

$161.02 /EA
NOT CURRENTLY IN STOCK
250V 125A RK1 TD FUSE

250V 125A RK1 TD FUSE

Item #: A2D125R

Supplier Part #: A2D125R
Brand: Mersen

Amp-Trap 2000 SmartSpot time-delay A2D-R fuses provide IEC Type 2 "no damage" protection to existing mains, feeders, and branch circuits serving motor and non-motor loads. A2D-R fuses will open fast enough under extreme fault conditions for maximum short circuit protection to prevent damage to motor starters, switches, and other circuit components, yet also provide the time-delay needed for motor in-rush currents. A2D-R fuses can be used to replace older 250V Class H, K or RK5 fuses already installed in the field.

Control panels; Recommended for Arc Flash energy reduction; Transformers; 300kA interrupting rating – self-certified, UL witnessed tests; Reduced inventory by taking the place of class RK5, K, and H fuses; Motors; Metal-embossed date and catalog number for easier traceability and lasting identification; CSA certified to standard C22.2 No. 248.12; Disconnects; Solid state SmartSpot visual blown fuse indicator; Easy 2-to-1 selectivity for prevention of nuisance shut downs and “black outs”; All general-purpose circuits; UL listed to standard 248-12 File E2137; DC listed to UL standard 248; Extremely current-limiting for low peak let-thru current; 600VAC & 600VDC dual rated; High-visibility orange label gives instant brand recognition; Safety switches; Fiberglass body provides dimensional stability in harsh industrial settings; Branch circuit protection; Rejection-style design prevents replacement errors (when used with recommended fuse blocks); Time-delay for motor starting and transformer inrush currents without nuisance opening

$142.25 /EA
NOT CURRENTLY IN STOCK
250V 150A RK1 TD FUSE

250V 150A RK1 TD FUSE

Item #: A2D150R

Supplier Part #: A2D150R
Brand: Mersen

Amp-Trap 2000 SmartSpot time-delay A2D-R fuses provide IEC Type 2 "no damage" protection to existing mains, feeders, and branch circuits serving motor and non-motor loads. A2D-R fuses will open fast enough under extreme fault conditions for maximum short circuit protection to prevent damage to motor starters, switches, and other circuit components, yet also provide the time-delay needed for motor in-rush currents. A2D-R fuses can be used to replace older 250V Class H, K or RK5 fuses already installed in the field.

CSA certified to standard C22.2 No. 248.12; Branch circuit protection; Recommended for Arc Flash energy reduction; UL listed to standard 248-12 File E2137; High-visibility orange label gives instant brand recognition; Metal-embossed date and catalog number for easier traceability and lasting identification; Motors; Reduced inventory by taking the place of class RK5, K, and H fuses; Rejection-style design prevents replacement errors (when used with recommended fuse blocks); All general-purpose circuits; Fiberglass body provides dimensional stability in harsh industrial settings; DC listed to UL standard 248; 600VAC & 600VDC dual rated; Disconnects; Safety switches; 300kA interrupting rating – self-certified, UL witnessed tests; Easy 2-to-1 selectivity for prevention of nuisance shut downs and “black outs”; Transformers; Solid state SmartSpot visual blown fuse indicator; Time-delay for motor starting and transformer inrush currents without nuisance opening; Extremely current-limiting for low peak let-thru current; Control panels

$142.25 /EA
NOT CURRENTLY IN STOCK
250V 175A RK1 TD FUSE

250V 175A RK1 TD FUSE

Item #: A2D175R

Supplier Part #: A2D175R
Brand: Mersen

Amp-Trap 2000 SmartSpot time-delay A2D-R fuses provide IEC Type 2 "no damage" protection to existing mains, feeders, and branch circuits serving motor and non-motor loads. A2D-R fuses will open fast enough under extreme fault conditions for maximum short circuit protection to prevent damage to motor starters, switches, and other circuit components, yet also provide the time-delay needed for motor in-rush currents. A2D-R fuses can be used to replace older 250V Class H, K or RK5 fuses already installed in the field.

Transformers; Time-delay for motor starting and transformer inrush currents without nuisance opening; Reduced inventory by taking the place of class RK5, K, and H fuses; Branch circuit protection; Metal-embossed date and catalog number for easier traceability and lasting identification; 600VAC & 600VDC dual rated; Fiberglass body provides dimensional stability in harsh industrial settings; Extremely current-limiting for low peak let-thru current; Rejection-style design prevents replacement errors (when used with recommended fuse blocks); Easy 2-to-1 selectivity for prevention of nuisance shut downs and “black outs”; DC listed to UL standard 248; Control panels; High-visibility orange label gives instant brand recognition; Disconnects; Motors; All general-purpose circuits; Solid state SmartSpot visual blown fuse indicator; 300kA interrupting rating – self-certified, UL witnessed tests; Recommended for Arc Flash energy reduction; Safety switches; CSA certified to standard C22.2 No. 248.12; UL listed to standard 248-12 File E2137

$149.11 /EA
NOT CURRENTLY IN STOCK
250V 200A RK1 TD FUSE

250V 200A RK1 TD FUSE

Item #: A2D200R

Supplier Part #: A2D200R
Brand: Mersen

Amp-Trap 2000 SmartSpot time-delay A2D-R fuses provide IEC Type 2 "no damage" protection to existing mains, feeders, and branch circuits serving motor and non-motor loads. A2D-R fuses will open fast enough under extreme fault conditions for maximum short circuit protection to prevent damage to motor starters, switches, and other circuit components, yet also provide the time-delay needed for motor in-rush currents. A2D-R fuses can be used to replace older 250V Class H, K or RK5 fuses already installed in the field.

Solid state SmartSpot visual blown fuse indicator; Easy 2-to-1 selectivity for prevention of nuisance shut downs and “black outs”; Reduced inventory by taking the place of class RK5, K, and H fuses; 300kA interrupting rating – self-certified, UL witnessed tests; Recommended for Arc Flash energy reduction; Rejection-style design prevents replacement errors (when used with recommended fuse blocks); High-visibility orange label gives instant brand recognition; Branch circuit protection; CSA certified to standard C22.2 No. 248.12; Time-delay for motor starting and transformer inrush currents without nuisance opening; Extremely current-limiting for low peak let-thru current; Motors; All general-purpose circuits; Metal-embossed date and catalog number for easier traceability and lasting identification; Transformers; Fiberglass body provides dimensional stability in harsh industrial settings; Disconnects; 600VAC & 600VDC dual rated; DC listed to UL standard 248; UL listed to standard 248-12 File E2137; Safety switches; Control panels

$142.25 /EA
NOT CURRENTLY IN STOCK
250V 110A RK1 FUSE

250V 110A RK1 FUSE

Item #: A2K110R

Supplier Part #: A2K110R
Brand: Mersen

Current-limiting Amp-Trap A2K-R fuses provide excellent protection where high available short-circuit currents exist. These fast-acting fuses are particularly good for branch/feeder circuits and back-up protection.

Panelboards; Bus duct; Fiberglass body provides dimensional stability in harsh industrial environments; UL listed to standard 248-12 File E2137; CSA certified to standard C22.2 No. 248.12; Load centers; Self-certified for DC per UL248; Feeder circuits; Switchboards; High degree of current limitation for low peak let-thru current; Lighting circuits; Rejection style design prevents replacement by other fuse classes; Non-inductive loads; Easy-to-read imprint label for quick recognition and replacement

$379.25 /EA
NOT CURRENTLY IN STOCK
250V 125A RK1 FUSE

250V 125A RK1 FUSE

Item #: A2K125R

Supplier Part #: A2K125R
Brand: Mersen

Current-limiting Amp-Trap A2K-R fuses provide excellent protection where high available short-circuit currents exist. These fast-acting fuses are particularly good for branch/feeder circuits and back-up protection.

Bus duct; Load centers; Self-certified for DC per UL248; Panelboards; Rejection style design prevents replacement by other fuse classes; Easy-to-read imprint label for quick recognition and replacement; Non-inductive loads; High degree of current limitation for low peak let-thru current; CSA certified to standard C22.2 No. 248.12; Switchboards; Fiberglass body provides dimensional stability in harsh industrial environments; Feeder circuits; UL listed to standard 248-12 File E2137; Lighting circuits

$363.00 /EA
NOT CURRENTLY IN STOCK
250V 150A RK1 FUSE

250V 150A RK1 FUSE

Item #: A2K150R

Supplier Part #: A2K150R
Brand: Mersen

Current-limiting Amp-Trap A2K-R fuses provide excellent protection where high available short-circuit currents exist. These fast-acting fuses are particularly good for branch/feeder circuits and back-up protection.

High degree of current limitation for low peak let-thru current; Load centers; Bus duct; Feeder circuits; CSA certified to standard C22.2 No. 248.12; Self-certified for DC per UL248; Fiberglass body provides dimensional stability in harsh industrial environments; Switchboards; Rejection style design prevents replacement by other fuse classes; Easy-to-read imprint label for quick recognition and replacement; Lighting circuits; UL listed to standard 248-12 File E2137; Non-inductive loads; Panelboards

$343.42 /EA
NOT CURRENTLY IN STOCK
250V 175A RK1 FUSE

250V 175A RK1 FUSE

Item #: A2K175R

Supplier Part #: A2K175R
Brand: Mersen

Current-limiting Amp-Trap A2K-R fuses provide excellent protection where high available short-circuit currents exist. These fast-acting fuses are particularly good for branch/feeder circuits and back-up protection.

Panelboards; UL listed to standard 248-12 File E2137; Feeder circuits; CSA certified to standard C22.2 No. 248.12; Bus duct; Rejection style design prevents replacement by other fuse classes; Fiberglass body provides dimensional stability in harsh industrial environments; Self-certified for DC per UL248; High degree of current limitation for low peak let-thru current; Load centers; Easy-to-read imprint label for quick recognition and replacement; Lighting circuits; Switchboards; Non-inductive loads

$363.72 /EA
NOT CURRENTLY IN STOCK
250V 200A RK1 FUSE

250V 200A RK1 FUSE

Item #: A2K200R

Supplier Part #: A2K200R
Brand: Mersen

Current-limiting Amp-Trap A2K-R fuses provide excellent protection where high available short-circuit currents exist. These fast-acting fuses are particularly good for branch/feeder circuits and back-up protection.

Rejection style design prevents replacement by other fuse classes; Switchboards; Feeder circuits; High degree of current limitation for low peak let-thru current; Easy-to-read imprint label for quick recognition and replacement; Bus duct; CSA certified to standard C22.2 No. 248.12; Panelboards; UL listed to standard 248-12 File E2137; Lighting circuits; Load centers; Fiberglass body provides dimensional stability in harsh industrial environments; Self-certified for DC per UL248; Non-inductive loads

$319.25 /EA