Browse Categories

Search in Category

Fuses

Search Filters

  • NH3 x

Filter Your Search

Show Attribute Brand
Hide Attribute Voltage

Shop by Category

Loading...

Fuses

Power Products/Fuses 
Viewing Page 1 of 9 (90 results)
NH 3 355A 690V GG

NH 3 355A 690V GG

Item #: C228507

Supplier Part #: C228507
Brand: Mersen

The NH system is classified among plug-in fuse systems and is composed of , fuse-base (possibly including terminal covers and phase barriers) , fuse-link with blade contact , fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional. Type "gG" NH fuse-links are full range breaking capacity fuse-links and are used to protect cables and equipment. They can interrupt any current surge, from the lowest fusing current up to their breaking capacity, and so can be used alone as protection. They also protect electrical devices and industrial set-ups from the electrodynamic effects of very high short-circuit currents.

Lead free contact blades; VDE 0636 Part 201; IEC 60269-1 and -2; Double indicator; Non-isolated gripping lugs; Dimensions according to DIN 43 620 parts 1 to 4; 0% cadmium

$468.79 /EA
NOT CURRENTLY IN STOCK
NH 3 630A 500V GG SGL

NH 3 630A 500V GG SGL

Item #: C229772

Supplier Part #: C229772
Brand: Mersen

The NH system is classified among plug-in fuse systems and is composed of , fuse-base (possibly including terminal covers and phase barriers) , fuse-link with blade contact , fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional. Type "gG" NH fuse-links are full range breaking capacity fuse-links and are used to protect cables and equipment. They can interrupt any current surge, from the lowest fusing current up to their breaking capacity, and so can be used alone as protection. They also protect electrical devices and industrial set-ups from the electrodynamic effects of very high short-circuit currents.

0% cadmium; IEC 60269-1 and -2; Double indicator; Lead free contact blades; Dimensions according to DIN 43 620 Parts 1 to 4; Isolated metal gripping lugs (SGL); VDE 0636 Part 201

$515.35 /EA
NOT CURRENTLY IN STOCK

6,9 GS 3 PV 0315

Item #: E322579

Supplier Part #: E322579
Brand: Mersen

The 690/700V Protistor® fuse-links provide maximum flexibility in equipment design and ultimate protection for today's power conversion equipment. These NH style fuse-links are defined as per DIN 43620/00 for a worldwide acceptance into NH modular system fuse-holders, fuse switch disconnectors for direct installation. The Protistor® have been engineered to provide state-of-the-art protection for semiconductors diodes, thyristors, GTO's and IGBT devices. Fuses are assembled with pure silver, die-cut elements embedded in solidified sand, which helps control arcing characteristics for a lower I²t and high interrupting rating level. All contact surfaces are silver plated and all hardware is non-magnetic. Each fuse-link can be equipped with a low voltage trip-indicator which can operate a field mountable microswitch.

Fast acting; Low I²t for improved semiconductor protection; No derating in standard NH fusegear; gS Class according to IEC 60269-4; High widstanding against inrush current and overloads; Reduced power dissipation; IEC 60269-4 Compliance; Excellent cycling capability; Multiple body sizes; CCC GB 1359.4; UL/CSA Recognized Component; Highly current limiting

$1,548.83 /EA
NOT CURRENTLY IN STOCK
NH 3 300A 690V AM

NH 3 300A 690V AM

Item #: E227980

Supplier Part #: E227980
Brand: Mersen

The NH system is classified among plug-in fuse systems and is composed of , fuse-base (possibly including terminal covers and phase barriers) , fuse-link with blade contact , fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional. Type "aM" NH fuse-links are partial-range breaking capacity fuse-links, used to protect motor circuits as they are strongly current-limiting and have low power losses. They interrupt currents from 6.3 times In up to their maximum breaking capacity and are therefore suited for short-circuit protection only. They must be associated with other switchgear for protection against overloads. These fuse-links can have a rated current equal to the motor's nominal current.

Double indicator; 0% cadmium; Dimensions according to DIN 43 620 parts 1 to 4; VDE 0636 Part 201; Non-isolated gripping lugs; Lead free contact blades; IEC 60269-1 and -2

$438.74 /EA
NOT CURRENTLY IN STOCK

6,9 URD 3 PV 0350

Item #: G320580

Supplier Part #: G320580
Brand: Mersen

The 690/700V Protistor® fuse-links provide maximum flexibility in equipment design and ultimate protection for today's power conversion equipment. These NH style fuse-links are defined as per DIN 43620/00 for a worldwide acceptance into NH modular system fuse-holders, fuse switch disconnectors for direct installation. The Protistor® have been engineered to provide state-of-the-art protection for semiconductors diodes, thyristors, GTO's and IGBT devices. Fuses are assembled with pure silver, die-cut elements embedded in solidified sand, which helps control arcing characteristics for a lower I²t and high interrupting rating level. All contact surfaces are silver plated and all hardware is non-magnetic. Each fuse-link can be equipped with a low voltage trip-indicator which can operate a field mountable microswitch.

IEC 60269-4 Compliance; UL/CSA Recognized Component; Very low I²t for improved semiconductor protection; Multiple body sizes; Current limiting; Superior cycling capability; aR Class according to VDE 636-23 and IEC 60269-4; Indication system with double indicator; Ultra fast acting

$1,544.45 /EA
NOT CURRENTLY IN STOCK
NH 3 355A 690V AM

NH 3 355A 690V AM

Item #: G227982

Supplier Part #: G227982
Brand: Mersen

The NH system is classified among plug-in fuse systems and is composed of , fuse-base (possibly including terminal covers and phase barriers) , fuse-link with blade contact , fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional. Type "aM" NH fuse-links are partial-range breaking capacity fuse-links, used to protect motor circuits as they are strongly current-limiting and have low power losses. They interrupt currents from 6.3 times In up to their maximum breaking capacity and are therefore suited for short-circuit protection only. They must be associated with other switchgear for protection against overloads. These fuse-links can have a rated current equal to the motor's nominal current.

Lead free contact blades; Dimensions according to DIN 43 620 parts 1 to 4; IEC 60269-1 and -2; Non-isolated gripping lugs; Double indicator; 0% cadmium; VDE 0636 Part 201

$456.02 /EA
NOT CURRENTLY IN STOCK

BASE NH 3-PP F/TORN. 3P

Item #: H215172

Supplier Part #: H215172
Brand: Mersen

NH fuse-bases are available for delivery in single-pole and three-pole designs and can be closely mounted in parallel rows. Each three-pole base is upplied with two phase-partition walls. NH fuse-links plugon covers which clip onto the contact springs can also be supplied for these bases. Plastic fuse-bases sizes 00 to 3 have a single-part plastic base while size 4 has a metal baseplate with 2 ceramic bases. The stable silver-plated contact springs are made of electrolytic copper and formed from one piece. Separate springing is provided by highly resilient captive steel springs, making the contact invulnerable to high thermal stress. Size 4 NH fuse-bases are designed for size 4 fuse-links with 8 mm contact blades. A microswitch (250VAC/10A, terminal size 6.3x0.8mm) can be used with NH fuse-links with striker, it operates when fuse melts or where there is no fuse-link. Indirect touch protection fuse bases no microswitch possible. Rated impulse withstand voltage Uimp 6kV / 8kV (sizes 00 / 0-4)

Multipolar bases possible by direct linkage in 00 size and with separator accessory in sizes 0, 1, 2 and 3; DIN VDE 0636-2, 0636-21; High-pressure spring contacts; Dimensions in accordance with DIN 43620; Screw or rail mounting; Polyamide insulating bases; IEC 60269 Compliance; Silver-plated contacts

$1,145.58 /EA
NOT CURRENTLY IN STOCK

NH 3 500A 500V AM

Item #: H223751

Supplier Part #: H223751
Brand: Mersen

The NH system is classified among plug-in fuse systems and is composed of , fuse-base (possibly including terminal covers and phase barriers) , fuse-link with blade contact , fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional. Type "gG" NH fuse-links are full range breaking capacity fuse-links and are used to protect cables and equipment. They can interrupt any current surge, from the lowest fusing current up to their breaking capacity, and so can be used alone as protection. They also protect electrical devices and industrial set-ups from the electrodynamic effects of very high short-circuit currents. Rated Power Dissipation values of Mersen NH fuse-links 400VAC are below the maximum values required by standard IEC 60269.

VDE 0636 Part 201; Dimensions according to DIN 43 620 Parts 1 to 4; Isolated metal gripping lugs (SGL); Double indicator; IEC 60269-1 and -2; Lead free contact blades; 0% cadmium

$436.58 /EA
NOT CURRENTLY IN STOCK
NH 3 400A 690V AM

NH 3 400A 690V AM

Item #: H227983

Supplier Part #: H227983
Brand: Mersen

The NH system is classified among plug-in fuse systems and is composed of , fuse-base (possibly including terminal covers and phase barriers) , fuse-link with blade contact , fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional. Type "aM" NH fuse-links are partial-range breaking capacity fuse-links, used to protect motor circuits as they are strongly current-limiting and have low power losses. They interrupt currents from 6.3 times In up to their maximum breaking capacity and are therefore suited for short-circuit protection only. They must be associated with other switchgear for protection against overloads. These fuse-links can have a rated current equal to the motor's nominal current.

Lead free contact blades; IEC 60269-1 and -2; Double indicator; Dimensions according to DIN 43 620 parts 1 to 4; VDE 0636 Part 201; 0% cadmium; Non-isolated gripping lugs

$456.02 /EA
NOT CURRENTLY IN STOCK
NH 3 630A 400V GG SGL

NH 3 630A 400V GG SGL

Item #: J201350

Supplier Part #: J201350
Brand: Mersen

The NH system is classified among plug-in fuse systems and is composed of , fuse-base (possibly including terminal covers and phase barriers) , fuse-link with blade contact , fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional. Type "gG" NH fuse-links are full range breaking capacity fuse-links and are used to protect cables and equipment. They can interrupt any current surge, from the lowest fusing current up to their breaking capacity, and so can be used alone as protection. They also protect electrical devices and industrial set-ups from the electrodynamic effects of very high short-circuit currents.

Isolated metal gripping lugs (SGL); Dimensions according to DIN 43 620 Parts 1 to 4; Lead free contact blades; 0% cadmium; VDE 0636 Part 201; Double indicator; IEC 60269-1 and -2

$436.58 /EA
NOT CURRENTLY IN STOCK
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • NEXT »