Fuses
250V 50A 3x13/16 RK5 TD F
High-grade silica filler ensures fast arc quenching and high current limitation; Motor circuits; General-purpose equipment; Easy-to-read label for quick brand recognition and replacement; Mains; Metal-embossed date and catalog number for traceability and lasting identification; Current-limiting; Time-delay; Service entrance equipment; Feeders; Current-limiting for low peak let-thru current; Rejection-style design prevents replacement errors (when used with recommended fuse blocks); AC & DC rated; Optional solid state SmartSpot blown fuse indicator; DC listed to UL standard 248 TRS only; UL listed to standard 248-12 File E2137; Branch circuits; Fiberglass body provides dimensional stability in harsh industrial settings; CSA certified to standard C22.2 no. 248.12; Time-delay for motor start-ups and transformer inrush currents without nuisance opening; Transformers
250V 40A RK1 TD FUSE
Transformers; All general-purpose circuits; CSA certified to standard C22.2 No. 248.12; Metal-embossed date and catalog number for easier traceability and lasting identification; Disconnects; Easy 2-to-1 selectivity for prevention of nuisance shut downs and “black outs”; 600VAC & 600VDC dual rated; Branch circuit protection; Motors; Time-delay for motor starting and transformer inrush currents without nuisance opening; 300kA interrupting rating – self-certified, UL witnessed tests; Safety switches; Fiberglass body provides dimensional stability in harsh industrial settings; Control panels; Solid state SmartSpot visual blown fuse indicator; UL listed to standard 248-12 File E2137; Extremely current-limiting for low peak let-thru current; Recommended for Arc Flash energy reduction; Rejection-style design prevents replacement errors (when used with recommended fuse blocks); High-visibility orange label gives instant brand recognition; Reduced inventory by taking the place of class RK5, K, and H fuses; DC listed to UL standard 248
250V 45A RK1 TD FUSE
High-visibility orange label gives instant brand recognition; UL listed to standard 248-12 File E2137; Transformers; Easy 2-to-1 selectivity for prevention of nuisance shut downs and “black outs”; 300kA interrupting rating – self-certified, UL witnessed tests; 600VAC & 600VDC dual rated; Rejection-style design prevents replacement errors (when used with recommended fuse blocks); CSA certified to standard C22.2 No. 248.12; Control panels; Motors; Branch circuit protection; Disconnects; Extremely current-limiting for low peak let-thru current; Time-delay for motor starting and transformer inrush currents without nuisance opening; Recommended for Arc Flash energy reduction; DC listed to UL standard 248; Reduced inventory by taking the place of class RK5, K, and H fuses; Solid state SmartSpot visual blown fuse indicator; Fiberglass body provides dimensional stability in harsh industrial settings; Metal-embossed date and catalog number for easier traceability and lasting identification; Safety switches; All general-purpose circuits
250V 50A RK1 TD FUSE
Extremely current-limiting for low peak let-thru current; Rejection-style design prevents replacement errors (when used with recommended fuse blocks); All general-purpose circuits; Recommended for Arc Flash energy reduction; Branch circuit protection; Metal-embossed date and catalog number for easier traceability and lasting identification; 300kA interrupting rating – self-certified, UL witnessed tests; Transformers; DC listed to UL standard 248; Easy 2-to-1 selectivity for prevention of nuisance shut downs and “black outs”; Time-delay for motor starting and transformer inrush currents without nuisance opening; Disconnects; Solid state SmartSpot visual blown fuse indicator; 600VAC & 600VDC dual rated; Reduced inventory by taking the place of class RK5, K, and H fuses; Control panels; UL listed to standard 248-12 File E2137; Safety switches; High-visibility orange label gives instant brand recognition; Fiberglass body provides dimensional stability in harsh industrial settings; Motors; CSA certified to standard C22.2 No. 248.12
250V 45A RK1 FUSE
Panelboards; Lighting circuits; Easy-to-read imprint label for quick recognition and replacement; High degree of current limitation for low peak let-thru current; CSA certified to standard C22.2 No. 248.12; Rejection style design prevents replacement by other fuse classes; Switchboards; Bus duct; Feeder circuits; Load centers; Self-certified for DC per UL248; Non-inductive loads; Fiberglass body provides dimensional stability in harsh industrial environments; UL listed to standard 248-12 File E2137
250V 50A RK1 FUSE
Lighting circuits; Feeder circuits; CSA certified to standard C22.2 No. 248.12; Rejection style design prevents replacement by other fuse classes; Bus duct; Non-inductive loads; Self-certified for DC per UL248; Fiberglass body provides dimensional stability in harsh industrial environments; Load centers; High degree of current limitation for low peak let-thru current; UL listed to standard 248-12 File E2137; Panelboards; Switchboards; Easy-to-read imprint label for quick recognition and replacement
250V 60A RK1 FUSE
Rejection style design prevents replacement by other fuse classes; Easy-to-read imprint label for quick recognition and replacement; Switchboards; Bus duct; UL listed to standard 248-12 File E2137; Panelboards; CSA certified to standard C22.2 No. 248.12; Feeder circuits; Lighting circuits; Load centers; Fiberglass body provides dimensional stability in harsh industrial environments; Self-certified for DC per UL248; High degree of current limitation for low peak let-thru current; Non-inductive loads
H TD FUSE 250V 35A CRN
Type D fuses satisfy the Canadian Electrical Code requirement for low melting-point fuses; CSA Certified
H TD FUSE 250V 40A CRN
Type D fuses satisfy the Canadian Electrical Code requirement for low melting-point fuses; CSA Certified
H TD FUSE 250V 45A CRN
Type D fuses satisfy the Canadian Electrical Code requirement for low melting-point fuses; CSA Certified