Search in Category
Filter Your Search
Shop by Category
Fuses
500V 20A TD MIDGET FUSE
1 1/2” x 13/32” (10 mm x 38 mm) dimensions; UL listed to standard 248-14 File E33925; Can be used with UltraSafe™ Fuse holders; Time-delay (12 seconds at 200 percent rating) for circuits with high inrush current; Numerous ratings for a wide variety of applications up to 500VAC; Supplemental protection of lighting, solenoid, motor and transformer circuits; CSA Certified to Standard C22.2 No. 248.14
500V 6A TD MIDGET FUSE
1 1/2” x 13/32” (10 mm x 38 mm) dimensions; Time-delay (12 seconds at 200 percent rating) for circuits with high inrush current; UL listed to standard 248-14 File E33925; Supplemental protection of lighting, solenoid, motor and transformer circuits; Numerous ratings for a wide variety of applications up to 500VAC; CSA Certified to Standard C22.2 No. 248.14; Can be used with UltraSafe™ Fuse holders
CC TD FUSE 600V 1-1/2A ATQR
High-grade silica filler ensures fast arc quenching and high current limitation; CSA certified to standard C22.2 No. 248.4; Lighting, heating & general-purpose loads; Highly current-limiting for low peak let-thru current; DC listed to UL standard 248; Rejection-style design prevents replacement errors (when used with recommended fuse blocks); Control transformers; UL listed to standard 248-4 File E2137; Solenoids; Fiberglass body provides dimensional stability in harsh industrial settings; Metal-embossed date and catalog number for traceability and lasting identification; Time-delay for control transformer inrush loads without nuisance opening; Inductive loads; High visibility orange label ensures instant brand recognition, and simplifies replacement
CC TD FUSE 600V 1/2A ATQR
Inductive loads; Solenoids; Metal-embossed date and catalog number for traceability and lasting identification; CSA certified to standard C22.2 No. 248.4; Control transformers; Rejection-style design prevents replacement errors (when used with recommended fuse blocks); Highly current-limiting for low peak let-thru current; High-grade silica filler ensures fast arc quenching and high current limitation; UL listed to standard 248-4 File E2137; Time-delay for control transformer inrush loads without nuisance opening; DC listed to UL standard 248; Lighting, heating & general-purpose loads; High visibility orange label ensures instant brand recognition, and simplifies replacement; Fiberglass body provides dimensional stability in harsh industrial settings
CC TD FUSE 600V 12A ATQR
Control transformers; Metal-embossed date and catalog number for traceability and lasting identification; Fiberglass body provides dimensional stability in harsh industrial settings; Inductive loads; High visibility orange label ensures instant brand recognition, and simplifies replacement; CSA certified to standard C22.2 No. 248.4; Highly current-limiting for low peak let-thru current; Solenoids; UL listed to standard 248-4 File E2137; DC listed to UL standard 248; High-grade silica filler ensures fast arc quenching and high current limitation; Rejection-style design prevents replacement errors (when used with recommended fuse blocks); Time-delay for control transformer inrush loads without nuisance opening; Lighting, heating & general-purpose loads
CC TD FUSE 600V 7-1/2A ATQR
Lighting, heating & general-purpose loads; Control transformers; Metal-embossed date and catalog number for traceability and lasting identification; Fiberglass body provides dimensional stability in harsh industrial settings; Rejection-style design prevents replacement errors (when used with recommended fuse blocks); Time-delay for control transformer inrush loads without nuisance opening; High visibility orange label ensures instant brand recognition, and simplifies replacement; DC listed to UL standard 248; UL listed to standard 248-4 File E2137; Solenoids; Inductive loads; High-grade silica filler ensures fast arc quenching and high current limitation; CSA certified to standard C22.2 No. 248.4; Highly current-limiting for low peak let-thru current
250V 5A RK1 TD FUSE
Solid state SmartSpot visual blown fuse indicator; All general-purpose circuits; 600VAC & 600VDC dual rated; Reduced inventory by taking the place of class RK5, K, and H fuses; Fiberglass body provides dimensional stability in harsh industrial settings; Transformers; CSA certified to standard C22.2 No. 248.12; 300kA interrupting rating – self-certified, UL witnessed tests; Easy 2-to-1 selectivity for prevention of nuisance shut downs and “black outs”; DC listed to UL standard 248; UL listed to standard 248-12 File E2137; Disconnects; Extremely current-limiting for low peak let-thru current; Time-delay for motor starting and transformer inrush currents without nuisance opening; Branch circuit protection; High-visibility orange label gives instant brand recognition; Rejection-style design prevents replacement errors (when used with recommended fuse blocks); Motors; Control panels; Metal-embossed date and catalog number for easier traceability and lasting identification; Recommended for Arc Flash energy reduction; Safety switches
SC FUSE 500V 90A QS BLADE
CSA Certified LR12636; DC Tested to UL standard 198L parameters (70-1200A); State-of-the-art protection for 500V equipment; Ultra compact sizes allow down-sizing of existing equipment; UL recognized component UL File 60314; Lowest I2t for greatest protection of semiconductor circuits; Low watts loss for cooler operation; Superior cycling ability gives an equipment design advantage; AC: UL guide no. JFHR2
600V 17-1/2A RK1 TD FUSE
Solid state SmartSpot visual blown fuse indicator; DC listed to UL standard 248; 300kA interrupting rating – self-certified, UL witnessed tests; 600VAC & 600VDC dual rated; Reduced inventory by taking the place of class RK5, K, and H fuses; Motors; Safety switches; Easy 2-to-1 selectivity for prevention of nuisance shut downs and “black outs”; UL listed to standard 248-12 File E2137; Recommended for Arc Flash energy reduction; High-visibility orange label gives instant brand recognition; Disconnects; All general-purpose circuits; Transformers; Branch circuit protection; CSA certified to standard C22.2 No. 248.12; Time-delay for motor starting and transformer inrush currents without nuisance opening; Rejection-style design prevents replacement errors (when used with recommended fuse blocks); Fiberglass body provides dimensional stability in harsh industrial settings; Extremely current-limiting for low peak let-thru current; Metal-embossed date and catalog number for easier traceability and lasting identification; Control panels
600V 50A CLASS T FUSE
Small physical size for greater design flexibility; CSA certified to standard C22.2 no. 248.15; Load centers; Metering centers; Panelboards; Switchboards; Extremely current-limiting for low peak let-thru current; Unique dimensions prevent replacement by other fuse classes; Circuit breakers; Blade-stamped catalog numbers for permanent identification; UL listed to standard 248-15 File E2137; DC listed to UL standard 248