600V 30A 3P CC ULTSFE

600V 30A 3P CC ULTSFE

Item #: USCC3

Supplier Part #: USCC3
Brand: Mersen

Mersen UltraSafe Modular Fuse holders introduce a new level of safety for Class CC (USCC) and Midget 1-1/2" x 13/32" (USM) AC and DC rated fuses up to 30 amperes. UltraSafe holders qualify as “Fingersafe” under IEC and DIN standards to an IP20 grade of protection, including fuse changing (with the flick of a finger). UltraSafe holders are available in 1, 2, 3 or 4 poles, with or without visual blown-fuse indicators in each pole. Multi-pole units can also be field assembled by ordering pin-tie handles. UltraSafe holders save up to 15% mounting space and any combination can be snapped onto 35mm DIN-rail for extra savings in panel building time. UltraSafe holders with Class CC fuses chosen for Type “2” No Damage protection give one of the safest protection packages in the industry. UltraSafe body material is tough and durable polyamide, with exceptional insulating properties.

DIN-rail mounting; CSA Certified C22.2; IP20 Finger-Safe (touch safe); ATM, DCT, ATMR recommended for DC applications; UL Listed to Standard 4248- 4 (class CC) and 4248-1 (midget), File E52283; Compact footprint; UL Listed to standard 4248-18 (photovoltaic), File E347822; IEC 60269-2-1 and 60947-3 Compliant (USM only); Optional visual blown fuse Indicator lights; Quick, tool-free, easy fuse change outs

$82.80 /EA
NOT CURRENTLY IN STOCK
CC FUSE BLOCK 600V 30A 3P PP

CC FUSE BLOCK 600V 30A 3P PP

Item #: 30323R

Supplier Part #: 30323R
Brand: Mersen

Mersen midget fuse blocks accommodate all 30 ampere 1-1/2” x 13/32” midget fuses. Class CC fuse blocks accommodate all 30 ampere Class CC fuses. A choice of box, screw, or pressure-plate connectors fit a wide range of stranded or solid copper wire. Insulators are glassfilled polycarbonate (GFPC) with verified dielectric strength in excess of 2500V. Fuse blocks feature a unique adder block which can be snapped onto 1-, 2- or 3-pole blocks to form multi-pole segmented blocks of as many poles as desired. All fuse clips are made of high conductivity tin-plated copper alloy.

UL listed, guide IZLT, File E52283; CSA certified class 6225, File 32169

$28.66 /EA
IN STOCK

600V 6A RK1 TD FUSE

Item #: A6D6R

Supplier Part #: A6D6R
Brand: Mersen

Amp-Trap 2000® SmartSpot time-delay A6D-R fuses provide IEC Type 2 "no damage" protection to existing mains, feeders, and branch circuits serving motor and non-motor loads. A6D-R fuses will open fast enough under extreme fault conditions for maximum short circuit protection to prevent damage to motor starters, switches, and other circuit components, yet also provide the time-delay needed for motor in-rush currents. A6D-R fuses can be used to replace older 600V Class H, K or RK5 fuses already installed in the field.

Easy 2-to-1 selectivity for prevention of nuisance shut downs and “black outs”; Time-delay for motor starting and transformer inrush currents without nuisance opening; Extremely current-limiting for low peak let-thru current; Metal-embossed date and catalog number for easier traceability and lasting identification; 300kA interrupting rating – self-certified, UL witnessed tests; Safety switches; 600VAC & 600VDC dual rated; DC listed to UL standard 248; Transformers; Reduced inventory by taking the place of class RK5, K, and H fuses; Solid state SmartSpot visual blown fuse indicator; Branch circuit protection; UL listed to standard 248-12 File E2137; Fiberglass body provides dimensional stability in harsh industrial settings; High-visibility orange label gives instant brand recognition; Disconnects; Rejection-style design prevents replacement errors (when used with recommended fuse blocks); CSA certified to standard C22.2 No. 248.12; Motors; All general-purpose circuits; Control panels; Recommended for Arc Flash energy reduction

$39.48 /EA
IN STOCK

600V 15A J TD NON-IND

Item #: AJT15N

Supplier Part #: AJT15N
Brand: Mersen

Amp-Trap 2000® AJT fuses provide non-indication as well as a SmartSpot visual open fuse indicator. With advanced material technology the AJT fuse provides IEC Type 2 No Damage protection to main, feeder, and branch circuits, for all types of loads — yet, they require only half the mounting space needed for 600VAC Class RK fuses. AJT’s time-delay characteristics are ideal for handling typical motor and transformer inrush currents, while also providing superior current-limiting ability.

Easy 2-to-1 selectivity for prevention of nuisance shutdowns; Time-delay for motor starting and transformer inrush; Most current-limiting UL class fuse; Lighting, heating & general loads; Load centers; Optional EI indicator/switch mount for AJT70 to 600 open fuse indication; IEC 60269-2-1; Small footprint requires less mounting space and allows smaller, more economical fuse blocks; Branch circuits; CSA certified to standard C22.2 No. 248.8; Metal-embossed date and catalog number for traceability and lasting identification; Fiberglass body provides dimensional stability in harsh industrial settings; Circuit breaker back-up; DC tested to UL standard 248; High-visibility orange label gives instant brand recognition; Extremely current-limiting for low peak let-thru current; UL listed; Bus duct; Unique Class J dimensions prevent replacement errors; UL listed to standard 248-8 File E2137; DC listed to UL standard 248; Mains; Transformers; Motor circuits; High-grade silica filler ensures fast arc quenching; 300kA interrupting rating – self-certified, UL witnessed tests; Feeders; Recommended for Arc Flash energy reduction; Control panels; Non-indicating or solid state SmartSpot visual blown fuse indicator

$35.29 /EA
IN STOCK

J TD FUSE 600V 45A AJT

Item #: AJT45

Supplier Part #: AJT45
Brand: Mersen

Amp-Trap 2000® AJT fuses provide non-indication as well as a SmartSpot visual open fuse indicator. With advanced material technology the AJT fuse provides IEC Type 2 No Damage protection to main, feeder, and branch circuits, for all types of loads — yet, they require only half the mounting space needed for 600VAC Class RK fuses. AJT’s time-delay characteristics are ideal for handling typical motor and transformer inrush currents, while also providing superior current-limiting ability.

Optional EI indicator/switch mount for AJT70 to 600 open fuse indication; Lighting, heating & general loads; Motor circuits; Bus duct; Fiberglass body provides dimensional stability in harsh industrial settings; CSA certified to standard C22.2 No. 248.8; DC tested to UL standard 248; Feeders; Control panels; Unique Class J dimensions prevent replacement errors; UL listed to standard 248-8 File E2137; Extremely current-limiting for low peak let-thru current; Easy 2-to-1 selectivity for prevention of nuisance shutdowns; Small footprint requires less mounting space and allows smaller, more economical fuse blocks; Non-indicating or solid state SmartSpot visual blown fuse indicator; Mains; Most current-limiting UL class fuse; Circuit breaker back-up; UL listed; High-visibility orange label gives instant brand recognition; DC listed to UL standard 248; Metal-embossed date and catalog number for traceability and lasting identification; 300kA interrupting rating – self-certified, UL witnessed tests; Load centers; Recommended for Arc Flash energy reduction; High-grade silica filler ensures fast arc quenching; Branch circuits; Transformers; IEC 60269-2-1; Time-delay for motor starting and transformer inrush

$64.11 /EA
IN STOCK
690V CP 14X51 GG 4A S/I FS

690V CP 14X51 GG 4A S/I FS

Item #: A219765

Supplier Part #: A219765
Brand: Mersen

Mersen aM and gG fuse-links cover a wide range of physical sizes and ampere ratings for 400, 500, and 690VAC for protection in electrical distribution circuits and various industrial applications. Most ratings are available in size 8x31 and size 10x38 with an optional indicator, and in size 14x51 and 22x58 with an optional striker to activate an auxiliary contact. Size 10x38 is also available with striker. All cylindrical fuse-links have ceramic bodies and silver-plated contacts. Cylindrical fuse-links "gG" are used for the protection of cables, motors and LV-networks. They limit and cut off unacceptable overcurrents and short-circuit currents up to their nominal breaking capacity. Cylindrical fuse-links "gG" also protect electrical equipment and installations against the dynamic effect of high short-currents. Our technology and process was designed to ensure highly reliable technical performance.

Approved by Lloyd’s Register of Shipping and Bureau Veritas; Striker version available for remote indication of fuse operation; Full range protection; IEC 60269-1 & -2; Reduced size; Safest and most reliable protection system

$17.45 /EA
IN STOCK
600V 125A CLASS J FUSE

600V 125A CLASS J FUSE

Item #: A4J125

Supplier Part #: A4J125
Brand: Mersen

Amp-Trap fast-acting A4J fuses deliver excellent current-limiting protection to a wide variety of applications. Their unique dimensions prevent the substitution of other fuses with lower voltage ratings, interrupting ratings, or current-limiting capability.

Circuit breakers; High current limitation for low peak let-thru current; Bus duct; Switchboards; IEC 269-2-1; Unique dimensions prevent replacement by other fuse classes; Load centers; Capacitors; UL listed to standard 248-8 File E2137; Panelboards; Fiberglass body provides dimensional stability in harsh industrial environments; Easy-to-read imprint label for quick recognition and replacement; Lighting, heating, and general loads; Feeder circuits; CSA certified to standard C22.2 no. 248.8; DC listed to UL 248

$228.22 /EA
NOT CURRENTLY IN STOCK
14248-FUSE,FORM 101

14248-FUSE,FORM 101

Item #: A50QS35-4

Supplier Part #: A50QS35-4
Brand: Mersen

A50QS Amp-Trap® Form 101 fuses grew out of the need to improve the overall performance of semiconductor fuses in response to new equipment requirements. The A50QS encompasses the best protection features – lower I2t to provide better protection for equipment, longer life when subjected to cyclic loading and lower watts loss. A50QS is today’s best choice for the protection of dynamic solid state equipment such as motor drives, inverters, UPS, etc.

Ultra compact sizes allow down-sizing of existing equipment; CSA Certified LR12636; Lowest I2t for greatest protection of semiconductor circuits; Superior cycling ability gives an equipment design advantage; AC: UL guide no. JFHR2; UL recognized component UL File 60314; State-of-the-art protection for 500V equipment; Low watts loss for cooler operation; DC Tested to UL standard 198L parameters (70-1200A)

$62.60 /EA
IN STOCK

J TD FUSE 600V 25A AJT

Item #: AJT25

Supplier Part #: AJT25
Brand: Mersen

Amp-Trap 2000® AJT fuses provide non-indication as well as a SmartSpot visual open fuse indicator. With advanced material technology the AJT fuse provides IEC Type 2 No Damage protection to main, feeder, and branch circuits, for all types of loads — yet, they require only half the mounting space needed for 600VAC Class RK fuses. AJT’s time-delay characteristics are ideal for handling typical motor and transformer inrush currents, while also providing superior current-limiting ability.

Optional EI indicator/switch mount for AJT70 to 600 open fuse indication; Feeders; Recommended for Arc Flash energy reduction; Easy 2-to-1 selectivity for prevention of nuisance shutdowns; Control panels; Time-delay for motor starting and transformer inrush; Bus duct; 300kA interrupting rating – self-certified, UL witnessed tests; Non-indicating or solid state SmartSpot visual blown fuse indicator; Fiberglass body provides dimensional stability in harsh industrial settings; Most current-limiting UL class fuse; UL listed to standard 248-8 File E2137; Transformers; CSA certified to standard C22.2 No. 248.8; High-grade silica filler ensures fast arc quenching; Small footprint requires less mounting space and allows smaller, more economical fuse blocks; High-visibility orange label gives instant brand recognition; IEC 60269-2-1; DC tested to UL standard 248; Load centers; Mains; Extremely current-limiting for low peak let-thru current; DC listed to UL standard 248; Circuit breaker back-up; UL listed; Unique Class J dimensions prevent replacement errors; Branch circuits; Motor circuits; Lighting, heating & general loads; Metal-embossed date and catalog number for traceability and lasting identification

$39.39 /EA
IN STOCK
CC TD FUSE 600V 7A ATDR

CC TD FUSE 600V 7A ATDR

Item #: ATDR7

Supplier Part #: ATDR7
Brand: Mersen

Amp-Trap 2000 time-delay ATDR small-dimension fuses provide IEC Type 2 "no damage" protection to your facility's increasingly sensitive branch circuit components and small motors - minimizing the risk of fault-related damage. ATDR Class CC fuses deliver the best time-delay characteristics in their class with excellent cycling ability for small motor loads.

Metal-embossed date and catalog number for traceability and lasting identification; Branch circuit protection; Lighting, heating & general loads; Rejection-style design prevents replacement errors (when used with recommended fuse blocks); Time-delay for motor starting inrush currents without nuisance opening; Contactors; DC listed to UL standard 248; Highly current-limiting for low peak let-thru current; CSA certified to standard C22.2 No. 248.4; Small motors; High-grade silica filler ensures fast arc quenching and optimum current-limitation; Fiberglass body provides dimensional stability in harsh industrial settings; Improved cycling ability for frequent motor starts/stops without nuisance fuse opening; UL listed to standard 248-4 File E2137; High-visibility orange label ensures instant brand recognition, simplifies replacement