Search in Category
Filter Your Search
Shop by Category
Fuses
600V 30A 5x13/16 TD FUSE
Rejection-style design prevents replacement errors (when used with recommended fuse blocks); UL listed to standard 248-12 File E2137; Current-limiting for low peak let-thru current; Easy-to-read label for quick brand recognition and replacement; Mains; Motor circuits; Current-limiting; Optional solid state SmartSpot blown fuse indicator; AC & DC rated; Metal-embossed date and catalog number for traceability and lasting identification; Fiberglass body provides dimensional stability in harsh industrial settings; High-grade silica filler ensures fast arc quenching and high current limitation; Branch circuits; General-purpose equipment; Transformers; Time-delay for motor start-ups and transformer inrush currents without nuisance opening; Feeders; Service entrance equipment; CSA certified to standard C22.2 no. 248.12; Time-delay; DC listed to UL standard 248 TRS only
600V 5-6/10A RK1 TD FUSE USE
Disconnects; Rejection-style design prevents replacement errors (when used with recommended fuse blocks); Fiberglass body provides dimensional stability in harsh industrial settings; Control panels; Recommended for Arc Flash energy reduction; 600VAC & 600VDC dual rated; Reduced inventory by taking the place of class RK5, K, and H fuses; CSA certified to standard C22.2 No. 248.12; DC listed to UL standard 248; Transformers; Safety switches; Branch circuit protection; Solid state SmartSpot visual blown fuse indicator; Time-delay for motor starting and transformer inrush currents without nuisance opening; Extremely current-limiting for low peak let-thru current; Metal-embossed date and catalog number for easier traceability and lasting identification; UL listed to standard 248-12 File E2137; Motors; High-visibility orange label gives instant brand recognition; Easy 2-to-1 selectivity for prevention of nuisance shut downs and “black outs”; All general-purpose circuits; 300kA interrupting rating – self-certified, UL witnessed tests
600V 6A RK1 TD FUSE
Easy 2-to-1 selectivity for prevention of nuisance shut downs and “black outs”; Time-delay for motor starting and transformer inrush currents without nuisance opening; Extremely current-limiting for low peak let-thru current; Metal-embossed date and catalog number for easier traceability and lasting identification; 300kA interrupting rating – self-certified, UL witnessed tests; Safety switches; 600VAC & 600VDC dual rated; DC listed to UL standard 248; Transformers; Reduced inventory by taking the place of class RK5, K, and H fuses; Solid state SmartSpot visual blown fuse indicator; Branch circuit protection; UL listed to standard 248-12 File E2137; Fiberglass body provides dimensional stability in harsh industrial settings; High-visibility orange label gives instant brand recognition; Disconnects; Rejection-style design prevents replacement errors (when used with recommended fuse blocks); CSA certified to standard C22.2 No. 248.12; Motors; All general-purpose circuits; Control panels; Recommended for Arc Flash energy reduction
600V 17-1/2A RK1 TD FUSE
Solid state SmartSpot visual blown fuse indicator; DC listed to UL standard 248; 300kA interrupting rating – self-certified, UL witnessed tests; 600VAC & 600VDC dual rated; Reduced inventory by taking the place of class RK5, K, and H fuses; Motors; Safety switches; Easy 2-to-1 selectivity for prevention of nuisance shut downs and “black outs”; UL listed to standard 248-12 File E2137; Recommended for Arc Flash energy reduction; High-visibility orange label gives instant brand recognition; Disconnects; All general-purpose circuits; Transformers; Branch circuit protection; CSA certified to standard C22.2 No. 248.12; Time-delay for motor starting and transformer inrush currents without nuisance opening; Rejection-style design prevents replacement errors (when used with recommended fuse blocks); Fiberglass body provides dimensional stability in harsh industrial settings; Extremely current-limiting for low peak let-thru current; Metal-embossed date and catalog number for easier traceability and lasting identification; Control panels
600V 4A RK1 FUSE
Self-certified for DC per UL248; Switchboards; Load centers; Panelboards; Easy-to-read imprint label for quick recognition and replacement; Non-inductive loads; Fiberglass body provides dimensional stability in harsh industrial environments; UL listed to standard 248-12 File E2137; High degree of current limitation for low peak let-thru current; Lighting circuits; Feeder circuits; Rejection style design prevents replacement by other fuse classes; Bus duct; CSA certified to standard C22.2 No. 248.12
600V 5A RK1 FUSE
High degree of current limitation for low peak let-thru current; UL listed to standard 248-12 File E2137; CSA certified to standard C22.2 No. 248.12; Panelboards; Feeder circuits; Load centers; Self-certified for DC per UL248; Non-inductive loads; Rejection style design prevents replacement by other fuse classes; Easy-to-read imprint label for quick recognition and replacement; Switchboards; Lighting circuits; Fiberglass body provides dimensional stability in harsh industrial environments; Bus duct
600V 6A RK1 FUSE
High degree of current limitation for low peak let-thru current; Load centers; Panelboards; Bus duct; Rejection style design prevents replacement by other fuse classes; CSA certified to standard C22.2 No. 248.12; Non-inductive loads; Easy-to-read imprint label for quick recognition and replacement; Switchboards; UL listed to standard 248-12 File E2137; Self-certified for DC per UL248; Lighting circuits; Fiberglass body provides dimensional stability in harsh industrial environments; Feeder circuits
600V 8A RK1 FUSE
Panelboards; UL listed to standard 248-12 File E2137; Self-certified for DC per UL248; Rejection style design prevents replacement by other fuse classes; Load centers; Feeder circuits; Non-inductive loads; High degree of current limitation for low peak let-thru current; CSA certified to standard C22.2 No. 248.12; Lighting circuits; Switchboards; Bus duct; Easy-to-read imprint label for quick recognition and replacement; Fiberglass body provides dimensional stability in harsh industrial environments
600V 1-1/4A RK1 TD FUSE SE
Fiberglass body provides dimensional stability in harsh industrial settings; All general-purpose circuits; Rejection-style design prevents replacement errors (when used with recommended fuse blocks); Metal-embossed date and catalog number for easier traceability and lasting identification; Control panels; High-visibility orange label gives instant brand recognition; DC listed to UL standard 248; 600VAC & 600VDC dual rated; Recommended for Arc Flash energy reduction; Time-delay for motor starting and transformer inrush currents without nuisance opening; Transformers; Disconnects; Extremely current-limiting for low peak let-thru current; Solid state SmartSpot visual blown fuse indicator; Easy 2-to-1 selectivity for prevention of nuisance shut downs and “black outs”; Safety switches; CSA certified to standard C22.2 No. 248.12; Branch circuit protection; Motors; Reduced inventory by taking the place of class RK5, K, and H fuses; 300kA interrupting rating – self-certified, UL witnessed tests; UL listed to standard 248-12 File E2137
600V 1-1/8A RK1 TD FUSE SE
Recommended for Arc Flash energy reduction; Metal-embossed date and catalog number for easier traceability and lasting identification; 300kA interrupting rating – self-certified, UL witnessed tests; Branch circuit protection; Extremely current-limiting for low peak let-thru current; Easy 2-to-1 selectivity for prevention of nuisance shut downs and “black outs”; Time-delay for motor starting and transformer inrush currents without nuisance opening; All general-purpose circuits; Control panels; Transformers; Motors; UL listed to standard 248-12 File E2137; Fiberglass body provides dimensional stability in harsh industrial settings; 600VAC & 600VDC dual rated; DC listed to UL standard 248; High-visibility orange label gives instant brand recognition; Reduced inventory by taking the place of class RK5, K, and H fuses; Solid state SmartSpot visual blown fuse indicator; Rejection-style design prevents replacement errors (when used with recommended fuse blocks); Disconnects; Safety switches; CSA certified to standard C22.2 No. 248.12