CC TD FUSE 600V 3A ATQR
Inductive loads; High-grade silica filler ensures fast arc quenching and high current limitation; DC listed to UL standard 248; Rejection-style design prevents replacement errors (when used with recommended fuse blocks); Control transformers; High visibility orange label ensures instant brand recognition, and simplifies replacement; UL listed to standard 248-4 File E2137; Time-delay for control transformer inrush loads without nuisance opening; Lighting, heating & general-purpose loads; CSA certified to standard C22.2 No. 248.4; Highly current-limiting for low peak let-thru current; Metal-embossed date and catalog number for traceability and lasting identification; Fiberglass body provides dimensional stability in harsh industrial settings; Solenoids
5X20MM FUSE 250V 2A GDG
1/16A through 10A, 250VAC, UL & CSA Recognized; Time-delay; Glass body; 1/16A through 6-3/10A, 250VAC, SEMKO Approved; 1/16A through 6-3/10A, 250VAC, VDE Approved; IEC 127-2 Standard Sheet 3; 5 mm x 20 mm
250V A SMALL DIM TD FUSE
1/10A through 3A, 250VAC, UL Listed and CSA Certified; 4A through 8A, 125VAC, UL Listed and CSA Certified; Time-delay; 10A, 125VAC, UL and CSA Recognized; Glass / ceramic body; 5 mm x 20 mm
5X20MM FUSE 250V 3A GSC
Time-delay; 4A through 8A, 125VAC, UL Listed and CSA Certified; 1/10A through 3A, 250VAC, UL Listed and CSA Certified; 5 mm x 20 mm; 10A, 125VAC, UL and CSA Recognized; Glass / ceramic body
600V 10A CLASS J HS FUSE
Optimized over-load capability for withstanding elevated levels of current during electronic motor controller starts; Control panels; Drives; UL listed to standard 248-8 File E2137; Branch circuits; Phase controllers; Excellent cycling ability for frequent starts/stops without nuisance opening; DC listed to UL 248; Electronic motor controllers; CSA certified to standard C22.2 no. 248.8; Low I2t (low thermal energy); Soft-starters; Solid state relays
600V 30A CLASS J HS FUSE
UL listed to standard 248-8 File E2137; Excellent cycling ability for frequent starts/stops without nuisance opening; DC listed to UL 248; Optimized over-load capability for withstanding elevated levels of current during electronic motor controller starts; Solid state relays; Branch circuits; Drives; Phase controllers; Low I2t (low thermal energy); Control panels; CSA certified to standard C22.2 no. 248.8; Electronic motor controllers; Soft-starters
PWR DIS BLK AL INT 310A 1P 2
UL Listed to subject 1953, File E352417 unless noted otherwise; CSA Certified Class 6228 01
600V 5-6/10A RK1 TD FUSE USE
Disconnects; Rejection-style design prevents replacement errors (when used with recommended fuse blocks); Fiberglass body provides dimensional stability in harsh industrial settings; Control panels; Recommended for Arc Flash energy reduction; 600VAC & 600VDC dual rated; Reduced inventory by taking the place of class RK5, K, and H fuses; CSA certified to standard C22.2 No. 248.12; DC listed to UL standard 248; Transformers; Safety switches; Branch circuit protection; Solid state SmartSpot visual blown fuse indicator; Time-delay for motor starting and transformer inrush currents without nuisance opening; Extremely current-limiting for low peak let-thru current; Metal-embossed date and catalog number for easier traceability and lasting identification; UL listed to standard 248-12 File E2137; Motors; High-visibility orange label gives instant brand recognition; Easy 2-to-1 selectivity for prevention of nuisance shut downs and “black outs”; All general-purpose circuits; 300kA interrupting rating – self-certified, UL witnessed tests
1000VDC/5A
Can be used with UltraSafeTM fuse holders USM series; 1 1/2” x 13/32” (10 mm x 38 mm) dimensions; Low minimum breaking capacity (MBC); Compact size: 10 × 38 mm (13/32” x 1-1/2”) size internationally accepted; Photovoltaic systems; UL Recognized component File E60314; Semiconductor protection; DC traction equipment; Multi-meters; Ferrule mount 1 to 30A for design versatility
1-1/4X1/4 FUSE 250V 1A GAB
Ceramic body; 1/8A through 15A, 250VAC, UL Listed and CSA Certified; Fast-acting; 1/4” x 1-1/4”; 20A through 30A, 250/125VAC, UL Recognized