Search in Category
Search Filters
-
Mersen x
Filter Your Search
Shop by Category
Fuses
1-1/4X1/4 FUSE 250V 3A GAB
1/8A through 15A, 250VAC, UL Listed and CSA Certified; Fast-acting; Ceramic body; 1/4” x 1-1/4”; 20A through 30A, 250/125VAC, UL Recognized
1-1/4X1/4 FUSE 250V 5A GAB
Fast-acting; 1/8A through 15A, 250VAC, UL Listed and CSA Certified; Ceramic body; 20A through 30A, 250/125VAC, UL Recognized; 1/4” x 1-1/4”
5X20MM FUSE 250V 1/4A GDG
1/16A through 10A, 250VAC, UL & CSA Recognized; Glass body; Time-delay; 1/16A through 6-3/10A, 250VAC, VDE Approved; IEC 127-2 Standard Sheet 3; 1/16A through 6-3/10A, 250VAC, SEMKO Approved; 5 mm x 20 mm
PWR DIS BLK AL INT 175A 3P 12
UL Listed to subject 1953, File E352417 unless noted otherwise; CSA Certified Class 6228 01
PWR DIS BLK AL INT 310A 3P 1S
CSA Certified Class 6228 01; UL Listed to subject 1953, File E352417 unless noted otherwise
250V 3A 1 1/2x13/32 MID TD
1 1/2” x 13/32” (10mm x 38mm) dimensions; Lighting circuits; CSA Certified to Standard C22.2 No. 248.14; 250VAC rating in all sizes up to 30A; Can be used with UltraSafeTM fuse holders; Small motors; UL listed to standard 248-14 File E33925; Time-delay for circuits with high inrush currrent; Small transformers; Control circuits; Numerous ratings for a wide variety of applications
250V 8A 1 1/2x13/32 MID TD
UL listed to standard 248-14 File E33925; Can be used with UltraSafeTM fuse holders; Control circuits; 1 1/2” x 13/32” (10mm x 38mm) dimensions; Small motors; Numerous ratings for a wide variety of applications; Time-delay for circuits with high inrush currrent; Lighting circuits; Small transformers; CSA Certified to Standard C22.2 No. 248.14; 250VAC rating in all sizes up to 30A
600V 10A CLASS J TD FUSE
Non-indicating or solid state SmartSpot visual blown fuse indicator; Small footprint requires less mounting space and allows smaller, more economical fuse blocks; Unique Class J dimensions prevent replacement errors; Fiberglass body provides dimensional stability in harsh industrial settings; Recommended for Arc Flash energy reduction; 300kA interrupting rating – self-certified, UL witnessed tests; Easy 2-to-1 selectivity for prevention of nuisance shutdowns; Circuit breaker back-up; Mains; Feeders; Transformers; Metal-embossed date and catalog number for traceability and lasting identification; UL listed to standard 248-8 File E2137; High-visibility orange label gives instant brand recognition; DC tested to UL standard 248; Motor circuits; High-grade silica filler ensures fast arc quenching; Bus duct; UL listed; Lighting, heating & general loads; IEC 60269-2-1; Extremely current-limiting for low peak let-thru current; Time-delay for motor starting and transformer inrush; CSA certified to standard C22.2 No. 248.8; Control panels; DC listed to UL standard 248; Branch circuits; Load centers; Most current-limiting UL class fuse; Optional EI indicator/switch mount for AJT70 to 600 open fuse indication
FUSE, CLASS J T/D (AJT15)
Most current-limiting UL class fuse; Load centers; Small footprint requires less mounting space and allows smaller, more economical fuse blocks; CSA certified to standard C22.2 No. 248.8; High-grade silica filler ensures fast arc quenching; Circuit breaker back-up; Optional EI indicator/switch mount for AJT70 to 600 open fuse indication; Lighting, heating & general loads; Easy 2-to-1 selectivity for prevention of nuisance shutdowns; Non-indicating or solid state SmartSpot visual blown fuse indicator; 300kA interrupting rating – self-certified, UL witnessed tests; DC tested to UL standard 248; Extremely current-limiting for low peak let-thru current; High-visibility orange label gives instant brand recognition; Branch circuits; Motor circuits; Mains; Feeders; Transformers; Time-delay for motor starting and transformer inrush; Bus duct; Fiberglass body provides dimensional stability in harsh industrial settings; Recommended for Arc Flash energy reduction; Unique Class J dimensions prevent replacement errors; UL listed to standard 248-8 File E2137; Control panels; Metal-embossed date and catalog number for traceability and lasting identification; DC listed to UL standard 248; UL listed; IEC 60269-2-1
J TD FUSE 600V 40A AJT
Lighting, heating & general loads; Metal-embossed date and catalog number for traceability and lasting identification; Time-delay for motor starting and transformer inrush; High-grade silica filler ensures fast arc quenching; Bus duct; UL listed; Unique Class J dimensions prevent replacement errors; Non-indicating or solid state SmartSpot visual blown fuse indicator; High-visibility orange label gives instant brand recognition; Feeders; 300kA interrupting rating – self-certified, UL witnessed tests; Motor circuits; Circuit breaker back-up; Extremely current-limiting for low peak let-thru current; Mains; Control panels; Transformers; Fiberglass body provides dimensional stability in harsh industrial settings; DC listed to UL standard 248; Recommended for Arc Flash energy reduction; UL listed to standard 248-8 File E2137; Branch circuits; Load centers; Most current-limiting UL class fuse; Optional EI indicator/switch mount for AJT70 to 600 open fuse indication; IEC 60269-2-1; Easy 2-to-1 selectivity for prevention of nuisance shutdowns; DC tested to UL standard 248; CSA certified to standard C22.2 No. 248.8; Small footprint requires less mounting space and allows smaller, more economical fuse blocks