Browse Categories

Search in Category

Fuses

Search Filters

  • Mersen x
  • 2.5 in x

Shop by Category

Loading...

Fuses

Power Products/Fuses 
Viewing Page 1 of 12 (112 results)
94688-FUSE,FORM 101

94688-FUSE,FORM 101

Item #: A70QS700-4

Supplier Part #: A70QS700-4
Brand: Mersen

A70QS Amp-Trap® high speed fuses were developed in response to the need for improved overall performance of 700V semiconductor fuses for new equipment requirements. A70QS fuses have lower I2t for better protection, longer life when subjected to cyclic loading, plus lower watts loss. A70QS is the best choice to protect dynamic solid state equipment such as motor drives, UPS, etc.

Low watts loss for cooler operation; Very Low I2t for improved protection of equipment; DC: tested to UL standard 198L parameters (35-800A); 700V AC/DC rating gives greater design versatility; UL recognized component, AC/DC UL file E60314; Ultra compact sizes allow down-sizing of existing equipment; AC: guide no. JFHR2; Superior cycling ability for long, reliable life on high cyclic loading; CSA certified File LR 12636

$605.71 /EA
NOT CURRENTLY IN STOCK
L TD FUSE 600V 1000A A4BQ

L TD FUSE 600V 1000A A4BQ

Item #: A4BQ1000

Supplier Part #: A4BQ1000
Brand: Mersen

Amp-Trap 2000 A4BQ fuses are 20 percent more current limiting than any other Class L fuse on the market. When correctly coordinated, they bring a superior level of protection to service entrance equipment. Downstream circuit components have maximum protection against short circuit let-thru current. A4BQ's built-in 4-second time-delay characteristic (at 500percent of rated current) accommodates harmless inrush currents with no nuisance opening.

DC listed to UL standard 248 (100-2000A); Circuit breaker back-up; Rejection-style design prevents replacement errors; Large motors; Recommended for Arc Flash energy reduction; Time-delay for high inrush loads such as motors and transformers, without nuisance opening; Reduced inventory because A4BQ can replace all older types of Class L fuses now in-service; Metal-embossed date and catalog number for traceability and lasting identification; Optional mechanical TA indicator (100-6000A). Please contact factory for special trigger actuator; 300kA interrupting rating – self-certified, UL witnessed tests; Most current-limiting for lowest peak let-thru current; even at fault currents up to 300kA; Lighting, heating & general loads; Mains; CSA certified to standard C22.2 No. 248.10 (601-6000A); Pure silver links ensure lowest let-thru current and longer fuse life; High-visibility orange label gives instant brand recognition; UL listed; Fastest operation under short circuit conditions: Let-thru currents are typically 20 percent lower, with a corresponding let-thru energy (clearing I2t) up to 40% lower than the next fastest Class L fuse; UL listed to standard 248-10 File E2137; Fiberglass body provides dimensional stability in harsh industrial settings; Easy 2-to-1 selectivity for prevention of nuisance shutdowns and “blackouts”; High-grade silica filler ensures fast arc quenching; Feeders

$1,269.97 /EA
NOT CURRENTLY IN STOCK
600V 600A CLASS J TD FUSE

600V 600A CLASS J TD FUSE

Item #: AJT600

Supplier Part #: AJT600
Brand: Mersen

Amp-Trap 2000® AJT fuses provide non-indication as well as a SmartSpot visual open fuse indicator. With advanced material technology the AJT fuse provides IEC Type 2 No Damage protection to main, feeder, and branch circuits, for all types of loads — yet, they require only half the mounting space needed for 600VAC Class RK fuses. AJT’s time-delay characteristics are ideal for handling typical motor and transformer inrush currents, while also providing superior current-limiting ability.

Time-delay for motor starting and transformer inrush; Control panels; CSA certified to standard C22.2 No. 248.8; Bus duct; Fiberglass body provides dimensional stability in harsh industrial settings; Mains; Feeders; DC listed to UL standard 248; UL listed; Non-indicating or solid state SmartSpot visual blown fuse indicator; Transformers; Load centers; Most current-limiting UL class fuse; Motor circuits; High-grade silica filler ensures fast arc quenching; Unique Class J dimensions prevent replacement errors; Recommended for Arc Flash energy reduction; Easy 2-to-1 selectivity for prevention of nuisance shutdowns; DC tested to UL standard 248; Extremely current-limiting for low peak let-thru current; Circuit breaker back-up; UL listed to standard 248-8 File E2137; Branch circuits; Small footprint requires less mounting space and allows smaller, more economical fuse blocks; Lighting, heating & general loads; IEC 60269-2-1; Optional EI indicator/switch mount for AJT70 to 600 open fuse indication; High-visibility orange label gives instant brand recognition; Metal-embossed date and catalog number for traceability and lasting identification; 300kA interrupting rating – self-certified, UL witnessed tests

$812.93 /EA
NOT CURRENTLY IN STOCK
CABLE FUSE 600V 750MCM C1

CABLE FUSE 600V 750MCM C1

Item #: CP750C1

Supplier Part #: CP750C1
Brand: Mersen

Mersen CP cable protectors are special purpose limiters which are crimped or bolted to cables to clear and isolate faults quickly, increasing the reliability of service entrance and distribution runs. They are current-limiting with a 200,000A interrupting rating, yet will carry low cable overloads which are handled by standard protective devices. Cable protectors are rated in terms of cable size and material (Al or Cu). Heat shrinkable (HS) tubing can be specified for field installation. For cables smaller than 4/0, class J fuses can be used.

Molded rubber boots or heat shrinkable tubing available for insulation and protection; Crimp terminals for aluminum cable include oxide inhibitor; Current limiting device; Fiberglass bodies for dimensional stability in harsh environments; Catalog number stamped into terminal for permanent identification; UL listed to File E305297; Permitted by National Electrical Code®

$2,128.35 /EA
NOT CURRENTLY IN STOCK
750MCM CABLE PROTECTOR

750MCM CABLE PROTECTOR

Item #: CPH750C1-HS

Supplier Part #: CPH750C1-HS
Brand: Mersen

Mersen CP cable protectors are special purpose limiters which are crimped or bolted to cables to clear and isolate faults quickly, increasing the reliability of service entrance and distribution runs. They are current-limiting with a 200,000A interrupting rating, yet will carry low cable overloads which are handled by standard protective devices. Cable protectors are rated in terms of cable size and material (Al or Cu). Heat shrinkable (HS) tubing can be specified for field installation. For cables smaller than 4/0, class J fuses can be used.

Molded rubber boots or heat shrinkable tubing available for insulation and protection; UL listed to File E305297; Crimp terminals for aluminum cable include oxide inhibitor; Catalog number stamped into terminal for permanent identification; Current limiting device; Fiberglass bodies for dimensional stability in harsh environments; Permitted by National Electrical Code®

$2,883.86 /EA
NOT CURRENTLY IN STOCK
1000VDC 450A CLASS J PV FUSE

1000VDC 450A CLASS J PV FUSE

Item #: HP10J450

Supplier Part #: HP10J450
Brand: Mersen

Mersen’s HP10J photovoltaic (PV) fuse series is designed specifically for DC Recombiner Boxes in the protection of 1000VDC photovoltaic systems. Its robust construction makes it ideal for continuous temperature and current cycling withstand adding to system longevity. The 1000VDC rated HP10J designed for low minimum breaking capacity capabilities of 1.35 times the fuse rated current value, allows for safe circuit interruption under typical low fault current conditions produced by PV arrays. Protect your off-grid or grid tied PV system from unexpected ground faults and line faults using Mersen’s HelioProtection® fuse line.

UL listed to Standard 248 File E2137 (70A to 400A); UL Listed to standard 2579 – Photovoltaic Fuses; Blown fuse indicator options available (EI option); Smallest available footprint in the industry; Temperature cycle withstand capability; Enlarged mounting holes; Low fault current interrupting capability; 200A to 400A available in NH3 mounting; CSA Component Certified C22.2 (70A to 400A); UL listed to Standard 2579 File E333668 (70A to 600A); Guaranteed operation at temperature extremes; Durable construction for enhanced system longevity

$2,076.44 /EA
NOT CURRENTLY IN STOCK
1000VDC 450A CLASS J PV FUSE -

1000VDC 450A CLASS J PV FUSE -

Item #: HP10J450EI

Supplier Part #: HP10J450EI
Brand: Mersen

Mersen’s HP10J photovoltaic (PV) fuse series is designed specifically for DC Recombiner Boxes in the protection of 1000VDC photovoltaic systems. Its robust construction makes it ideal for continuous temperature and current cycling withstand adding to system longevity. The 1000VDC rated HP10J designed for low minimum breaking capacity capabilities of 1.35 times the fuse rated current value, allows for safe circuit interruption under typical low fault current conditions produced by PV arrays. Protect your off-grid or grid tied PV system from unexpected ground faults and line faults using Mersen’s HelioProtection® fuse line.

Smallest available footprint in the industry; UL listed to Standard 248 File E2137 (70A to 400A); Temperature cycle withstand capability; 200A to 400A available in NH3 mounting; UL listed to Standard 2579 File E333668 (70A to 600A); UL Listed to standard 2579 – Photovoltaic Fuses; Guaranteed operation at temperature extremes; Enlarged mounting holes; Blown fuse indicator options available (EI option); CSA Component Certified C22.2 (70A to 400A); Low fault current interrupting capability; Durable construction for enhanced system longevity

$2,242.66 /EA
NOT CURRENTLY IN STOCK
1000VDC 500A CLASS J PV FUSE

1000VDC 500A CLASS J PV FUSE

Item #: HP10J500

Supplier Part #: HP10J500
Brand: Mersen

Mersen’s HP10J photovoltaic (PV) fuse series is designed specifically for DC Recombiner Boxes in the protection of 1000VDC photovoltaic systems. Its robust construction makes it ideal for continuous temperature and current cycling withstand adding to system longevity. The 1000VDC rated HP10J designed for low minimum breaking capacity capabilities of 1.35 times the fuse rated current value, allows for safe circuit interruption under typical low fault current conditions produced by PV arrays. Protect your off-grid or grid tied PV system from unexpected ground faults and line faults using Mersen’s HelioProtection® fuse line.

Blown fuse indicator options available (EI option); Enlarged mounting holes; Temperature cycle withstand capability; 200A to 400A available in NH3 mounting; Guaranteed operation at temperature extremes; Durable construction for enhanced system longevity; UL listed to Standard 248 File E2137 (70A to 400A); Smallest available footprint in the industry; UL listed to Standard 2579 File E333668 (70A to 600A); UL Listed to standard 2579 – Photovoltaic Fuses; CSA Component Certified C22.2 (70A to 400A); Low fault current interrupting capability

$2,076.44 /EA
NOT CURRENTLY IN STOCK
1000VDC 500A CLASS J PV FUSE -

1000VDC 500A CLASS J PV FUSE -

Item #: HP10J500EI

Supplier Part #: HP10J500EI
Brand: Mersen

Mersen’s HP10J photovoltaic (PV) fuse series is designed specifically for DC Recombiner Boxes in the protection of 1000VDC photovoltaic systems. Its robust construction makes it ideal for continuous temperature and current cycling withstand adding to system longevity. The 1000VDC rated HP10J designed for low minimum breaking capacity capabilities of 1.35 times the fuse rated current value, allows for safe circuit interruption under typical low fault current conditions produced by PV arrays. Protect your off-grid or grid tied PV system from unexpected ground faults and line faults using Mersen’s HelioProtection® fuse line.

200A to 400A available in NH3 mounting; Low fault current interrupting capability; Smallest available footprint in the industry; Blown fuse indicator options available (EI option); CSA Component Certified C22.2 (70A to 400A); Temperature cycle withstand capability; Guaranteed operation at temperature extremes; Enlarged mounting holes; UL listed to Standard 2579 File E333668 (70A to 600A); UL Listed to standard 2579 – Photovoltaic Fuses; Durable construction for enhanced system longevity; UL listed to Standard 248 File E2137 (70A to 400A)

$2,242.66 /EA
NOT CURRENTLY IN STOCK
1000VDC 600A CLASS J PV FUSE

1000VDC 600A CLASS J PV FUSE

Item #: HP10J600

Supplier Part #: HP10J600
Brand: Mersen

Mersen’s HP10J photovoltaic (PV) fuse series is designed specifically for DC Recombiner Boxes in the protection of 1000VDC photovoltaic systems. Its robust construction makes it ideal for continuous temperature and current cycling withstand adding to system longevity. The 1000VDC rated HP10J designed for low minimum breaking capacity capabilities of 1.35 times the fuse rated current value, allows for safe circuit interruption under typical low fault current conditions produced by PV arrays. Protect your off-grid or grid tied PV system from unexpected ground faults and line faults using Mersen’s HelioProtection® fuse line.

Enlarged mounting holes; Blown fuse indicator options available (EI option); Durable construction for enhanced system longevity; UL listed to Standard 248 File E2137 (70A to 400A); CSA Component Certified C22.2 (70A to 400A); UL Listed to standard 2579 – Photovoltaic Fuses; Guaranteed operation at temperature extremes; Temperature cycle withstand capability; Smallest available footprint in the industry; Low fault current interrupting capability; 200A to 400A available in NH3 mounting; UL listed to Standard 2579 File E333668 (70A to 600A)

$2,076.44 /EA
NOT CURRENTLY IN STOCK
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • NEXT »