Browse Categories

Fuses

Power Products/Fuses 
Viewing Page 2 of 61 (602 results)

NH 1 40A 690V AM

Item #: G227890

Supplier Part #: G227890
Brand: Mersen

The NH system is classified among plug-in fuse systems and is composed of , fuse-base (possibly including terminal covers and phase barriers) , fuse-link with blade contact , fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional. Type "aM" NH fuse-links are partial-range breaking capacity fuse-links, used to protect motor circuits as they are strongly current-limiting and have low power losses. They interrupt currents from 6.3 times In up to their maximum breaking capacity and are therefore suited for short-circuit protection only. They must be associated with other switchgear for protection against overloads. These fuse-links can have a rated current equal to the motor's nominal current.

0% cadmium; Non-isolated gripping lugs; Lead free contact blades; Double indicator; IEC 60269-1 and -2; VDE 0636 Part 201; Dimensions according to DIN 43 620 parts 1 to 4

$188.72 /EA
NOT CURRENTLY IN STOCK
NH 3 355A 690V AM

NH 3 355A 690V AM

Item #: G227982

Supplier Part #: G227982
Brand: Mersen

The NH system is classified among plug-in fuse systems and is composed of , fuse-base (possibly including terminal covers and phase barriers) , fuse-link with blade contact , fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional. Type "aM" NH fuse-links are partial-range breaking capacity fuse-links, used to protect motor circuits as they are strongly current-limiting and have low power losses. They interrupt currents from 6.3 times In up to their maximum breaking capacity and are therefore suited for short-circuit protection only. They must be associated with other switchgear for protection against overloads. These fuse-links can have a rated current equal to the motor's nominal current.

Lead free contact blades; Dimensions according to DIN 43 620 parts 1 to 4; IEC 60269-1 and -2; Non-isolated gripping lugs; Double indicator; 0% cadmium; VDE 0636 Part 201

$456.02 /EA
NOT CURRENTLY IN STOCK

NH 000 6A 690V GG

Item #: G228442

Supplier Part #: G228442
Brand: Mersen

The NH system is classified among plug-in fuse systems and is composed of , fuse-base (possibly including terminal covers and phase barriers) , fuse-link with blade contact , fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional. Type "gG" NH fuse-links are full range breaking capacity fuse-links and are used to protect cables and equipment. They can interrupt any current surge, from the lowest fusing current up to their breaking capacity, and so can be used alone as protection. They also protect electrical devices and industrial set-ups from the electrodynamic effects of very high short-circuit currents.

Non-isolated gripping lugs; 0% cadmium; IEC 60269-1 and -2; Double indicator; VDE 0636 Part 201; Dimensions according to DIN 43 620 parts 1 to 4; Lead free contact blades

$123.49 /EA
NOT CURRENTLY IN STOCK

NH 1 200A 500V AM

Item #: G232513

Supplier Part #: G232513
Brand: Mersen

The NH system is classified among plug-in fuse systems and is composed of , fuse-base (possibly including terminal covers and phase barriers) , fuse-link with blade contact , fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional. Type "aM" NH fuse-links are partial-range breaking capacity fuse-links, used to protect motor circuits as they are strongly current-limiting and have low power losses. They interrupt currents from 6.3 times In up to their maximum breaking capacity and are therefore suited for short-circuit protection only. They must be associated with other switchgear for protection against overloads. These fuse-links can have a rated current equal to the motor's nominal current.

VDE 0636 Part 201; IEC 60269-1 and -2; Dimensions according to DIN 43 620 parts 1 to 4; Non-isolated gripping lugs; 0% cadmium; Double indicator; Lead free contact blades

$201.85 /EA
NOT CURRENTLY IN STOCK

H 2409P BCKUP 442-88/200

Item #: F1000114

Supplier Part #: F1000114
Brand: Mersen

Mersen HV fuse-links have been used for reliable protection in high-voltage switchgear and controlgear and high-voltage systems for decades. Limitor®-P HV fuses are back-up fuses as defined in the IEC 60282-1 standard and dedicated to protect transformers against effects of short-circuit currents. To guarantee high quality, Mersen uses the best materials fuse-elements are in pure silver, caps are in copper coated with silver and bodies are in ceramic.

DIN 43625; IEC 60282-1; Low switching voltage; Indoor and outdoor applications; Energy efficency; VDE 0670 part 4; High current limitation; New cap design for a better compatibility with all types of clips and easier assembly; Quick breaking; Medium striker 80N/30mm; Coordination with IEC 60787, IEC 62271-105, IEC/TR 62655

$564.17 /EA
NOT CURRENTLY IN STOCK

NH 2 63A 500V GG SGL

Item #: F211605

Supplier Part #: F211605
Brand: Mersen

The NH system is classified among plug-in fuse systems and is composed of , fuse-base (possibly including terminal covers and phase barriers) , fuse-link with blade contact , fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional. Type "gG" NH fuse-links are full range breaking capacity fuse-links and are used to protect cables and equipment. They can interrupt any current surge, from the lowest fusing current up to their breaking capacity, and so can be used alone as protection. They also protect electrical devices and industrial set-ups from the electrodynamic effects of very high short-circuit currents.

Double indicator; Isolated metal gripping lugs (SGL); VDE 0636 Part 201; IEC 60269-1 and -2; Dimensions according to DIN 43 620 Parts 1 to 4; 0% cadmium; Lead free contact blades

$268.32 /EA
NOT CURRENTLY IN STOCK
FUS.HICAP AM NH0 C/P 100A

FUS.HICAP AM NH0 C/P 100A

Item #: F215676

Supplier Part #: F215676
Brand: Mersen

The NH system is classified among plug-in fuse systems and is composed of , fuse-base (possibly including terminal covers and phase barriers) , fuse-link with blade contact , fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current, it must be handled by a qualified professional.

Dimensions according to DIN 43 620 Parts 1 to 4; Lead free contact blades; 0% cadmium; IEC 60269-1 and -2; VDE 0636 Part 201

$222.47 /EA
NOT CURRENTLY IN STOCK

NH 3 450A 500V GG SGL

Item #: F216205

Supplier Part #: F216205
Brand: Mersen

The NH system is classified among plug-in fuse systems and is composed of , fuse-base (possibly including terminal covers and phase barriers) , fuse-link with blade contact , fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional. Type "gG" NH fuse-links are full range breaking capacity fuse-links and are used to protect cables and equipment. They can interrupt any current surge, from the lowest fusing current up to their breaking capacity, and so can be used alone as protection. They also protect electrical devices and industrial set-ups from the electrodynamic effects of very high short-circuit currents.

VDE 0636 Part 201; Lead free contact blades; Double indicator; Isolated metal gripping lugs (SGL); 0% cadmium; IEC 60269-1 and -2; Dimensions according to DIN 43 620 Parts 1 to 4

$436.58 /EA
NOT CURRENTLY IN STOCK

NH 0 160A 500V GG

Item #: F223013

Supplier Part #: F223013
Brand: Mersen

The NH system is classified among plug-in fuse systems and is composed of , fuse-base (possibly including terminal covers and phase barriers) , fuse-link with blade contact , fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional. Type "gG" NH fuse-links are full range breaking capacity fuse-links and are used to protect cables and equipment. They can interrupt any current surge, from the lowest fusing current up to their breaking capacity, and so can be used alone as protection. They also protect electrical devices and industrial set-ups from the electrodynamic effects of very high short-circuit currents.

0% cadmium; VDE 0636 Part 201; Dimensions according to DIN 43 620 parts 1 to 4; IEC 60269-1 and -2; Non-isolated gripping lugs; Double indicator; Lead free contact blades

$160.67 /EA
NOT CURRENTLY IN STOCK

NH 000 25A 400V GG

Item #: F223680

Supplier Part #: F223680
Brand: Mersen

The NH system is classified among plug-in fuse systems and is composed of , fuse-base (possibly including terminal covers and phase barriers) , fuse-link with blade contact , fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional. Type "gG" NH fuse-links are full range breaking capacity fuse-links and are used to protect cables and equipment. They can interrupt any current surge, from the lowest fusing current up to their breaking capacity, and so can be used alone as protection. They also protect electrical devices and industrial set-ups from the electrodynamic effects of very high short-circuit currents. Rated Power Dissipation values of Mersen NH fuse-links 400VAC are below the maximum values required by standard IEC 60269.

0% cadmium; VDE 0636 Part 201; Dimensions according to DIN 43 620 Parts 1 to 4; Non-isolated gripping lugs; Double indicator; Lead free contact blades; IEC 60269-1 and -2

$130.06 /EA
NOT CURRENTLY IN STOCK
  • « PREV
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • NEXT »