Browse Categories

Fuses

Power Products/Fuses 
Viewing Page 8 of 61 (602 results)
FUS.HICAP AM NH0 C/P 40A

FUS.HICAP AM NH0 C/P 40A

Item #: R213639

Supplier Part #: R213639
Brand: Mersen

The NH system is classified among plug-in fuse systems and is composed of , fuse-base (possibly including terminal covers and phase barriers) , fuse-link with blade contact , fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current, it must be handled by a qualified professional.

0% cadmium; Lead free contact blades; Dimensions according to DIN 43 620 Parts 1 to 4; IEC 60269-1 and -2; VDE 0636 Part 201

$222.47 /EA
NOT CURRENTLY IN STOCK

D01-SICH.EINS. 440V 10A GL-GG

Item #: S201358

Supplier Part #: S201358
Brand: Mersen

The D0 fuse-system is installed in low voltage distribution units, where fuse-links are accessible to non trained persons and can also be replaced by them. The system is the most modern of the screw systems and designed for 400VAC/250VDC networks. The D0 fuse range comprises the standardized fuse sizes D01, D02 and D03. The range of applications for D0 fuse-links for general application is the protection of cables and power lines. They limit and cut off unacceptable overcurrents and short circuit currents up to their nominal breaking capacity. D0 fuse-links "gG" also protect equipments and installations against dynamic effects of high short circuit currents.

Insulated body suitable for high mechanical and thermal impacts; Optimized size; Safe cut-off short circuits and over currents due to special design of fuse element; Resistant to aging; Low power dissipation; Top and bottom contacts made of nickel plated or silver plated copper alloy; DIN VDE 0636-3; Clear indication of operation condition due to coloured indicator un top contact

$39.59 /EA
NOT CURRENTLY IN STOCK

NH 2 250A 500V GG

Item #: R222494

Supplier Part #: R222494
Brand: Mersen

The NH system is classified among plug-in fuse systems and is composed of , fuse-base (possibly including terminal covers and phase barriers) , fuse-link with blade contact , fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional. Type "gG" NH fuse-links are full range breaking capacity fuse-links and are used to protect cables and equipment. They can interrupt any current surge, from the lowest fusing current up to their breaking capacity, and so can be used alone as protection. They also protect electrical devices and industrial set-ups from the electrodynamic effects of very high short-circuit currents.

IEC 60269-1 and -2; Dimensions according to DIN 43 620 parts 1 to 4; Non-isolated gripping lugs; Lead free contact blades; Double indicator; VDE 0636 Part 201; 0% cadmium

$248.98 /EA
NOT CURRENTLY IN STOCK

H 3609P BCKUP 537-56/6,3

Item #: S209362

Supplier Part #: S209362
Brand: Mersen

Mersen HV fuse-links have been used for reliable protection in high-voltage switchgear and controlgear and high-voltage systems for decades. Limitor®-PD HV fuses are back-up fuses as defined in the standards IEC 60282-1 and VDE 0670 T402 and dedicated to protect transformers against effects of short-circuit currents. The VDE 0670 T402 defines fuses between 6.3A and 160A, for other ratings, thanks to consult Limitor®-P HV fuses range. To guarantee high quality, Mersen uses the best materials fuse-elements are in pure silver, caps are in copper coated with silver and bodies are in ceramic.

VDE 0670 part 402; New cap design for a better compatibility with all types of clips; Energy efficency; Coordination with IEC 60787, IEC 62271-105, IEC/TR 62655; IEC 60282-1; VDE 0670 part 4; medium striker 80N/30mm; Low switching voltage; Quick breaking; Indoor and outdoor applications; DIN 43625; and easier assembly; High current limitation

$731.91 /EA
NOT CURRENTLY IN STOCK
NH 3 250A 500V GG SGL

NH 3 250A 500V GG SGL

Item #: S211087

Supplier Part #: S211087
Brand: Mersen

The NH system is classified among plug-in fuse systems and is composed of , fuse-base (possibly including terminal covers and phase barriers) , fuse-link with blade contact , fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional. Type "gG" NH fuse-links are full range breaking capacity fuse-links and are used to protect cables and equipment. They can interrupt any current surge, from the lowest fusing current up to their breaking capacity, and so can be used alone as protection. They also protect electrical devices and industrial set-ups from the electrodynamic effects of very high short-circuit currents.

Lead free contact blades; Isolated metal gripping lugs (SGL); VDE 0636 Part 201; 0% cadmium; Double indicator; Dimensions according to DIN 43 620 Parts 1 to 4; IEC 60269-1 and -2

$436.58 /EA
NOT CURRENTLY IN STOCK

D02-SICH.EINS. 440V 25A GL-GG

Item #: S213663

Supplier Part #: S213663
Brand: Mersen

The D0 fuse-system is installed in low voltage distribution units, where fuse-links are accessible to non trained persons and can also be replaced by them. The system is the most modern of the screw systems and designed for 400VAC/250VDC networks. The D0 fuse range comprises the standardized fuse sizes D01, D02 and D03. The range of applications for D0 fuse-links for general application is the protection of cables and power lines. They limit and cut off unacceptable overcurrents and short circuit currents up to their nominal breaking capacity. D0 fuse-links "gG" also protect equipments and installations against dynamic effects of high short circuit currents.

DIN VDE 0636-3; Top and bottom contacts made of nickel plated or silver plated copper alloy; Insulated body suitable for high mechanical and thermal impacts; Clear indication of operation condition due to coloured indicator un top contact; Low power dissipation; Resistant to aging; Optimized size; Safe cut-off short circuits and over currents due to special design of fuse element

$44.42 /EA
NOT CURRENTLY IN STOCK
690V NH0 C/P gG 35A

690V NH0 C/P gG 35A

Item #: S214146

Supplier Part #: S214146
Brand: Mersen

The NH system is classified among plug-in fuse systems and is composed of , fuse-base (possibly including terminal covers and phase barriers) , fuse-link with blade contact , fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional. Type "gG" NH fuse-links are full range breaking capacity fuse-links and are used to protect cables and equipment. They can interrupt any current surge, from the lowest fusing current up to their breaking capacity, and so can be used alone as protection. They also protect electrical devices and industrial set-ups from the electrodynamic effects of very high short-circuit currents.

0% cadmium; Lead free contact blades; Dimensions according to DIN 43 620 Parts 1 to 4; IEC 60269-1 and -2; VDE 0636 Part 201

$296.78 /EA
NOT CURRENTLY IN STOCK

NH 3 400A 500V GG

Item #: S214675

Supplier Part #: S214675
Brand: Mersen

The NH system is classified among plug-in fuse systems and is composed of , fuse-base (possibly including terminal covers and phase barriers) , fuse-link with blade contact , fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional. Type "gG" NH fuse-links are full range breaking capacity fuse-links and are used to protect cables and equipment. They can interrupt any current surge, from the lowest fusing current up to their breaking capacity, and so can be used alone as protection. They also protect electrical devices and industrial set-ups from the electrodynamic effects of very high short-circuit currents.

Dimensions according to DIN 43 620 Parts 1 to 4; Lead free contact blades; 0% cadmium; Isolated metal gripping lugs (SGL); VDE 0636 Part 201; IEC 60269-1 and -2; Double indicator

$436.58 /EA
NOT CURRENTLY IN STOCK

NH 000 25A 500V AM

Item #: R232499

Supplier Part #: R232499
Brand: Mersen

The NH system is classified among plug-in fuse systems and is composed of , fuse-base (possibly including terminal covers and phase barriers) , fuse-link with blade contact , fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional. Type "aM" NH fuse-links are partial-range breaking capacity fuse-links, used to protect motor circuits as they are strongly current-limiting and have low power losses. They interrupt currents from 6.3 times In up to their maximum breaking capacity and are therefore suited for short-circuit protection only. They must be associated with other switchgear for protection against overloads. These fuse-links can have a rated current equal to the motor's nominal current.

Lead free contact blades; Dimensions according to DIN 43 620 parts 1 to 4; VDE 0636 Part 201; IEC 60269-1 and -2; Non-isolated gripping lugs; Double indicator; 0% cadmium

$133.49 /EA
NOT CURRENTLY IN STOCK

NH 3 500A 500V GG

Item #: S217734

Supplier Part #: S217734
Brand: Mersen

The NH system is classified among plug-in fuse systems and is composed of , fuse-base (possibly including terminal covers and phase barriers) , fuse-link with blade contact , fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional. Type "gG" NH fuse-links are full range breaking capacity fuse-links and are used to protect cables and equipment. They can interrupt any current surge, from the lowest fusing current up to their breaking capacity, and so can be used alone as protection. They also protect electrical devices and industrial set-ups from the electrodynamic effects of very high short-circuit currents.

VDE 0636 Part 201; 0% cadmium; Lead free contact blades; Dimensions according to DIN 43 620 parts 1 to 4; Non-isolated gripping lugs; Double indicator; IEC 60269-1 and -2

$366.42 /EA
NOT CURRENTLY IN STOCK