Browse Categories

Fuses

Power Products/Fuses 
Viewing Page 9 of 61 (602 results)

NH 0 25A 500V GG SGL

Item #: P214672

Supplier Part #: P214672
Brand: Mersen

The NH system is classified among plug-in fuse systems and is composed of , fuse-base (possibly including terminal covers and phase barriers) , fuse-link with blade contact , fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional. Type "gG" NH fuse-links are full range breaking capacity fuse-links and are used to protect cables and equipment. They can interrupt any current surge, from the lowest fusing current up to their breaking capacity, and so can be used alone as protection. They also protect electrical devices and industrial set-ups from the electrodynamic effects of very high short-circuit currents.

0% cadmium; Isolated metal gripping lugs (SGL); Dimensions according to DIN 43 620 Parts 1 to 4; Double indicator; Lead free contact blades; IEC 60269-1 and -2; VDE 0636 Part 201

$161.60 /EA
NOT CURRENTLY IN STOCK

NH 0 40A 500V gG

Item #: P217731

Supplier Part #: P217731
Brand: Mersen

The NH system is classified among plug-in fuse systems and is composed of , fuse-base (possibly including terminal covers and phase barriers) , fuse-link with blade contact , fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional. Type "gG" NH fuse-links are full range breaking capacity fuse-links and are used to protect cables and equipment. They can interrupt any current surge, from the lowest fusing current up to their breaking capacity, and so can be used alone as protection. They also protect electrical devices and industrial set-ups from the electrodynamic effects of very high short-circuit currents.

0% cadmium; Non-isolated gripping lugs; IEC 60269-1 and -2; VDE 0636 Part 201; Double indicator; Dimensions according to DIN 43 620 parts 1 to 4; Lead free contact blades

$150.42 /EA
NOT CURRENTLY IN STOCK

690V NH1 C/P gG 125A

Item #: P219801

Supplier Part #: P219801
Brand: Mersen

The NH system is classified among plug-in fuse systems and is composed of , fuse-base (possibly including terminal covers and phase barriers) , fuse-link with blade contact , fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional. Type "gG" NH fuse-links are full range breaking capacity fuse-links and are used to protect cables and equipment. They can interrupt any current surge, from the lowest fusing current up to their breaking capacity, and so can be used alone as protection. They also protect electrical devices and industrial set-ups from the electrodynamic effects of very high short-circuit currents.

Lead free contact blades; VDE 0636 Part 201; 0% cadmium; IEC 60269-1 and -2; Dimensions according to DIN 43 620 Parts 1 to 4

$267.91 /EA
NOT CURRENTLY IN STOCK
NH 000 2A 690V AM

NH 000 2A 690V AM

Item #: P227851

Supplier Part #: P227851
Brand: Mersen

The NH system is classified among plug-in fuse systems and is composed of , fuse-base (possibly including terminal covers and phase barriers) , fuse-link with blade contact , fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional. Type "aM" NH fuse-links are partial-range breaking capacity fuse-links, used to protect motor circuits as they are strongly current-limiting and have low power losses. They interrupt currents from 6.3 times In up to their maximum breaking capacity and are therefore suited for short-circuit protection only. They must be associated with other switchgear for protection against overloads. These fuse-links can have a rated current equal to the motor's nominal current.

IEC 60269-1 and -2; Dimensions according to DIN 43 620 parts 1 to 4; 0% cadmium; VDE 0636 Part 201; Double indicator; Non-isolated gripping lugs; Lead free contact blades

$128.52 /EA
NOT CURRENTLY IN STOCK

NH 0 25A 690V AM

Item #: P227874

Supplier Part #: P227874
Brand: Mersen

The NH system is classified among plug-in fuse systems and is composed of , fuse-base (possibly including terminal covers and phase barriers) , fuse-link with blade contact , fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional. Type "aM" NH fuse-links are partial-range breaking capacity fuse-links, used to protect motor circuits as they are strongly current-limiting and have low power losses. They interrupt currents from 6.3 times In up to their maximum breaking capacity and are therefore suited for short-circuit protection only. They must be associated with other switchgear for protection against overloads. These fuse-links can have a rated current equal to the motor's nominal current.

0% cadmium; Double indicator; IEC 60269-1 and -2; Non-isolated gripping lugs; Dimensions according to DIN 43 620 parts 1 to 4; VDE 0636 Part 201; Lead free contact blades

$152.83 /EA
NOT CURRENTLY IN STOCK

NH 1 200A 690V AM

Item #: P227897

Supplier Part #: P227897
Brand: Mersen

The NH system is classified among plug-in fuse systems and is composed of , fuse-base (possibly including terminal covers and phase barriers) , fuse-link with blade contact , fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional. Type "aM" NH fuse-links are partial-range breaking capacity fuse-links, used to protect motor circuits as they are strongly current-limiting and have low power losses. They interrupt currents from 6.3 times In up to their maximum breaking capacity and are therefore suited for short-circuit protection only. They must be associated with other switchgear for protection against overloads. These fuse-links can have a rated current equal to the motor's nominal current.

IEC 60269-1 and -2; Double indicator; 0% cadmium; Lead free contact blades; VDE 0636 Part 201; Dimensions according to DIN 43 620 parts 1 to 4; Non-isolated gripping lugs

$189.24 /EA
NOT CURRENTLY IN STOCK

NH 2 63A 690V AM

Item #: P227966

Supplier Part #: P227966
Brand: Mersen

The NH system is classified among plug-in fuse systems and is composed of , fuse-base (possibly including terminal covers and phase barriers) , fuse-link with blade contact , fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional. Type "aM" NH fuse-links are partial-range breaking capacity fuse-links, used to protect motor circuits as they are strongly current-limiting and have low power losses. They interrupt currents from 6.3 times In up to their maximum breaking capacity and are therefore suited for short-circuit protection only. They must be associated with other switchgear for protection against overloads. These fuse-links can have a rated current equal to the motor's nominal current.

VDE 0636 Part 201; Dimensions according to DIN 43 620 parts 1 to 4; Non-isolated gripping lugs; Double indicator; 0% cadmium; Lead free contact blades; IEC 60269-1 and -2

$246.68 /EA
NOT CURRENTLY IN STOCK

NH 000 35A 690V GG

Item #: P228449

Supplier Part #: P228449
Brand: Mersen

The NH system is classified among plug-in fuse systems and is composed of , fuse-base (possibly including terminal covers and phase barriers) , fuse-link with blade contact , fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional. Type "gG" NH fuse-links are full range breaking capacity fuse-links and are used to protect cables and equipment. They can interrupt any current surge, from the lowest fusing current up to their breaking capacity, and so can be used alone as protection. They also protect electrical devices and industrial set-ups from the electrodynamic effects of very high short-circuit currents.

Double indicator; VDE 0636 Part 201; Dimensions according to DIN 43 620 parts 1 to 4; Non-isolated gripping lugs; 0% cadmium; IEC 60269-1 and -2; Lead free contact blades

$123.49 /EA
NOT CURRENTLY IN STOCK

NH 0 80A 690V GG

Item #: P228472

Supplier Part #: P228472
Brand: Mersen

The NH system is classified among plug-in fuse systems and is composed of , fuse-base (possibly including terminal covers and phase barriers) , fuse-link with blade contact , fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional. Type "gG" NH fuse-links are full range breaking capacity fuse-links and are used to protect cables and equipment. They can interrupt any current surge, from the lowest fusing current up to their breaking capacity, and so can be used alone as protection. They also protect electrical devices and industrial set-ups from the electrodynamic effects of very high short-circuit currents.

Dimensions according to DIN 43 620 parts 1 to 4; IEC 60269-1 and -2; Double indicator; Non-isolated gripping lugs; VDE 0636 Part 201; Lead free contact blades; 0% cadmium

$158.06 /EA
NOT CURRENTLY IN STOCK

NH 2 100A 690V GG

Item #: P228495

Supplier Part #: P228495
Brand: Mersen

The NH system is classified among plug-in fuse systems and is composed of , fuse-base (possibly including terminal covers and phase barriers) , fuse-link with blade contact , fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional. Type "gG" NH fuse-links are full range breaking capacity fuse-links and are used to protect cables and equipment. They can interrupt any current surge, from the lowest fusing current up to their breaking capacity, and so can be used alone as protection. They also protect electrical devices and industrial set-ups from the electrodynamic effects of very high short-circuit currents.

VDE 0636 Part 201; 0% cadmium; Double indicator; IEC 60269-1 and -2; Lead free contact blades; Dimensions according to DIN 43 620 parts 1 to 4; Non-isolated gripping lugs

$242.32 /EA
NOT CURRENTLY IN STOCK
  • « PREV
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • NEXT »