NH 3 250A 690V AM

NH 3 250A 690V AM

Item #: D227979

Supplier Part #: D227979
Brand: Mersen

The NH system is classified among plug-in fuse systems and is composed of , fuse-base (possibly including terminal covers and phase barriers) , fuse-link with blade contact , fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional. Type "aM" NH fuse-links are partial-range breaking capacity fuse-links, used to protect motor circuits as they are strongly current-limiting and have low power losses. They interrupt currents from 6.3 times In up to their maximum breaking capacity and are therefore suited for short-circuit protection only. They must be associated with other switchgear for protection against overloads. These fuse-links can have a rated current equal to the motor's nominal current.

Lead free contact blades; 0% cadmium; IEC 60269-1 and -2; Double indicator; Non-isolated gripping lugs; Dimensions according to DIN 43 620 parts 1 to 4; VDE 0636 Part 201

$438.74 /EA
NOT CURRENTLY IN STOCK

NH 3 400A 690V GG

Item #: D228508

Supplier Part #: D228508
Brand: Mersen

The NH system is classified among plug-in fuse systems and is composed of , fuse-base (possibly including terminal covers and phase barriers) , fuse-link with blade contact , fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional. Type "gG" NH fuse-links are full range breaking capacity fuse-links and are used to protect cables and equipment. They can interrupt any current surge, from the lowest fusing current up to their breaking capacity, and so can be used alone as protection. They also protect electrical devices and industrial set-ups from the electrodynamic effects of very high short-circuit currents.

IEC 60269-1 and -2; Lead free contact blades; Dimensions according to DIN 43 620 parts 1 to 4; Non-isolated gripping lugs; Double indicator; VDE 0636 Part 201; 0% cadmium

$468.79 /EA
NOT CURRENTLY IN STOCK
NH 3 800A 500V GG

NH 3 800A 500V GG

Item #: D229773

Supplier Part #: D229773
Brand: Mersen

The NH system is classified among plug-in fuse systems and is composed of , fuse-base (possibly including terminal covers and phase barriers) , fuse-link with blade contact , fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional. Type "gG" NH fuse-links are full range breaking capacity fuse-links and are used to protect cables and equipment. They can interrupt any current surge, from the lowest fusing current up to their breaking capacity, and so can be used alone as protection. They also protect electrical devices and industrial set-ups from the electrodynamic effects of very high short-circuit currents.

Isolated metal gripping lugs (SGL); Double indicator; IEC 60269-1 and -2; Dimensions according to DIN 43 620 Parts 1 to 4; 0% cadmium; Lead free contact blades; VDE 0636 Part 201

$515.35 /EA
NOT CURRENTLY IN STOCK

NH 3 425A 690V GG

Item #: E228509

Supplier Part #: E228509
Brand: Mersen

The NH system is classified among plug-in fuse systems and is composed of , fuse-base (possibly including terminal covers and phase barriers) , fuse-link with blade contact , fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional. Type "gG" NH fuse-links are full range breaking capacity fuse-links and are used to protect cables and equipment. They can interrupt any current surge, from the lowest fusing current up to their breaking capacity, and so can be used alone as protection. They also protect electrical devices and industrial set-ups from the electrodynamic effects of very high short-circuit currents.

Dimensions according to DIN 43 620 parts 1 to 4; Double indicator; Non-isolated gripping lugs; 0% cadmium; IEC 60269-1 and -2; Lead free contact blades; VDE 0636 Part 201

$468.79 /EA
NOT CURRENTLY IN STOCK

NH 3 450A 500V GG SGL

Item #: F216205

Supplier Part #: F216205
Brand: Mersen

The NH system is classified among plug-in fuse systems and is composed of , fuse-base (possibly including terminal covers and phase barriers) , fuse-link with blade contact , fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional. Type "gG" NH fuse-links are full range breaking capacity fuse-links and are used to protect cables and equipment. They can interrupt any current surge, from the lowest fusing current up to their breaking capacity, and so can be used alone as protection. They also protect electrical devices and industrial set-ups from the electrodynamic effects of very high short-circuit currents.

VDE 0636 Part 201; Lead free contact blades; Double indicator; Isolated metal gripping lugs (SGL); 0% cadmium; IEC 60269-1 and -2; Dimensions according to DIN 43 620 Parts 1 to 4

$436.58 /EA
NOT CURRENTLY IN STOCK
NH 3 315A 690V AM

NH 3 315A 690V AM

Item #: F227981

Supplier Part #: F227981
Brand: Mersen

The NH system is classified among plug-in fuse systems and is composed of , fuse-base (possibly including terminal covers and phase barriers) , fuse-link with blade contact , fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional. Type "aM" NH fuse-links are partial-range breaking capacity fuse-links, used to protect motor circuits as they are strongly current-limiting and have low power losses. They interrupt currents from 6.3 times In up to their maximum breaking capacity and are therefore suited for short-circuit protection only. They must be associated with other switchgear for protection against overloads. These fuse-links can have a rated current equal to the motor's nominal current.

IEC 60269-1 and -2; Non-isolated gripping lugs; Dimensions according to DIN 43 620 parts 1 to 4; Double indicator; 0% cadmium; Lead free contact blades; VDE 0636 Part 201

$456.02 /EA
NOT CURRENTLY IN STOCK

NH 3 500A 690V GG

Item #: F228510

Supplier Part #: F228510
Brand: Mersen

The NH system is classified among plug-in fuse systems and is composed of , fuse-base (possibly including terminal covers and phase barriers) , fuse-link with blade contact , fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional. Type "gG" NH fuse-links are full range breaking capacity fuse-links and are used to protect cables and equipment. They can interrupt any current surge, from the lowest fusing current up to their breaking capacity, and so can be used alone as protection. They also protect electrical devices and industrial set-ups from the electrodynamic effects of very high short-circuit currents.

Lead free contact blades; Non-isolated gripping lugs; Double indicator; IEC 60269-1 and -2; 0% cadmium; Dimensions according to DIN 43 620 parts 1 to 4; VDE 0636 Part 201

$473.04 /EA
NOT CURRENTLY IN STOCK
NH 3 355A 690V GG SGL

NH 3 355A 690V GG SGL

Item #: F229775

Supplier Part #: F229775
Brand: Mersen

The NH system is classified among plug-in fuse systems and is composed of , fuse-base (possibly including terminal covers and phase barriers) , fuse-link with blade contact , fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional. Type "gG" NH fuse-links are full range breaking capacity fuse-links and are used to protect cables and equipment. They can interrupt any current surge, from the lowest fusing current up to their breaking capacity, and so can be used alone as protection. They also protect electrical devices and industrial set-ups from the electrodynamic effects of very high short-circuit currents.

Isolated metal gripping lugs (SGL); Lead free contact blades; VDE 0636 Part 201; IEC 60269-1 and -2; 0% cadmium; Double indicator; Dimensions according to DIN 43 620 Parts 1 to 4

$515.35 /EA
NOT CURRENTLY IN STOCK
NH 3 300A 500V GG SGL

NH 3 300A 500V GG SGL

Item #: G211606

Supplier Part #: G211606
Brand: Mersen

The NH system is classified among plug-in fuse systems and is composed of , fuse-base (possibly including terminal covers and phase barriers) , fuse-link with blade contact , fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional. Type "gG" NH fuse-links are full range breaking capacity fuse-links and are used to protect cables and equipment. They can interrupt any current surge, from the lowest fusing current up to their breaking capacity, and so can be used alone as protection. They also protect electrical devices and industrial set-ups from the electrodynamic effects of very high short-circuit currents.

Lead free contact blades; Dimensions according to DIN 43 620 Parts 1 to 4; VDE 0636 Part 201; Isolated metal gripping lugs (SGL); Double indicator; IEC 60269-1 and -2; 0% cadmium

$436.58 /EA
NOT CURRENTLY IN STOCK
NH 3 355A 690V AM

NH 3 355A 690V AM

Item #: G227982

Supplier Part #: G227982
Brand: Mersen

The NH system is classified among plug-in fuse systems and is composed of , fuse-base (possibly including terminal covers and phase barriers) , fuse-link with blade contact , fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional. Type "aM" NH fuse-links are partial-range breaking capacity fuse-links, used to protect motor circuits as they are strongly current-limiting and have low power losses. They interrupt currents from 6.3 times In up to their maximum breaking capacity and are therefore suited for short-circuit protection only. They must be associated with other switchgear for protection against overloads. These fuse-links can have a rated current equal to the motor's nominal current.

Lead free contact blades; Dimensions according to DIN 43 620 parts 1 to 4; IEC 60269-1 and -2; Non-isolated gripping lugs; Double indicator; 0% cadmium; VDE 0636 Part 201

$456.02 /EA
NOT CURRENTLY IN STOCK