Browse Categories

Search in Category

Fuses

Search Filters

  • Hungary x
  • NH1 x

Filter Your Search

Show Attribute Brand

Shop by Category

Loading...

Fuses

Power Products/Fuses 
Viewing Page 1 of 12 (114 results)

NH 1 224A 400V GG SGL

Item #: D223724

Supplier Part #: D223724
Brand: Mersen

The NH system is classified among plug-in fuse systems and is composed of , fuse-base (possibly including terminal covers and phase barriers) , fuse-link with blade contact , fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional. Type "gG" NH fuse-links are full range breaking capacity fuse-links and are used to protect cables and equipment. They can interrupt any current surge, from the lowest fusing current up to their breaking capacity, and so can be used alone as protection. They also protect electrical devices and industrial set-ups from the electrodynamic effects of very high short-circuit currents. Rated Power Dissipation values of Mersen NH fuse-links 400VAC are below the maximum values required by standard IEC 60269.

Dimensions according to DIN 43 620 Parts 1 to 4; Lead free contact blades; VDE 0636 Part 201; 0% cadmium; IEC 60269-1 and -2; Isolated metal gripping lugs (SGL); Double indicator

$229.14 /EA
NOT CURRENTLY IN STOCK

NH 1 25A 690V AM

Item #: D227887

Supplier Part #: D227887
Brand: Mersen

The NH system is classified among plug-in fuse systems and is composed of , fuse-base (possibly including terminal covers and phase barriers) , fuse-link with blade contact , fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional. Type "aM" NH fuse-links are partial-range breaking capacity fuse-links, used to protect motor circuits as they are strongly current-limiting and have low power losses. They interrupt currents from 6.3 times In up to their maximum breaking capacity and are therefore suited for short-circuit protection only. They must be associated with other switchgear for protection against overloads. These fuse-links can have a rated current equal to the motor's nominal current.

Lead free contact blades; Dimensions according to DIN 43 620 parts 1 to 4; 0% cadmium; VDE 0636 Part 201; Double indicator; IEC 60269-1 and -2; Non-isolated gripping lugs

$181.60 /EA
NOT CURRENTLY IN STOCK

NH 1 100A 690V GG

Item #: D228485

Supplier Part #: D228485
Brand: Mersen

The NH system is classified among plug-in fuse systems and is composed of , fuse-base (possibly including terminal covers and phase barriers) , fuse-link with blade contact , fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional. Type "gG" NH fuse-links are full range breaking capacity fuse-links and are used to protect cables and equipment. They can interrupt any current surge, from the lowest fusing current up to their breaking capacity, and so can be used alone as protection. They also protect electrical devices and industrial set-ups from the electrodynamic effects of very high short-circuit currents.

IEC 60269-1 and -2; Dimensions according to DIN 43 620 parts 1 to 4; Double indicator; 0% cadmium; Lead free contact blades; VDE 0636 Part 201; Non-isolated gripping lugs

$190.16 /EA
NOT CURRENTLY IN STOCK

NH 1 125A 690V GG SGL

Item #: D229750

Supplier Part #: D229750
Brand: Mersen

The NH system is classified among plug-in fuse systems and is composed of , fuse-base (possibly including terminal covers and phase barriers) , fuse-link with blade contact , fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional. Type "gG" NH fuse-links are full range breaking capacity fuse-links and are used to protect cables and equipment. They can interrupt any current surge, from the lowest fusing current up to their breaking capacity, and so can be used alone as protection. They also protect electrical devices and industrial set-ups from the electrodynamic effects of very high short-circuit currents.

VDE 0636 Part 201; Double indicator; 0% cadmium; Lead free contact blades; IEC 60269-1 and -2; Dimensions according to DIN 43 620 Parts 1 to 4; Isolated metal gripping lugs (SGL)

$209.29 /EA
NOT CURRENTLY IN STOCK
NH 1 100A 500V AM

NH 1 100A 500V AM

Item #: D232510

Supplier Part #: D232510
Brand: Mersen

The NH system is classified among plug-in fuse systems and is composed of , fuse-base (possibly including terminal covers and phase barriers) , fuse-link with blade contact , fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional. Type "aM" NH fuse-links are partial-range breaking capacity fuse-links, used to protect motor circuits as they are strongly current-limiting and have low power losses. They interrupt currents from 6.3 times In up to their maximum breaking capacity and are therefore suited for short-circuit protection only. They must be associated with other switchgear for protection against overloads. These fuse-links can have a rated current equal to the motor's nominal current.

Double indicator; VDE 0636 Part 201; Non-isolated gripping lugs; Dimensions according to DIN 43 620 parts 1 to 4; Lead free contact blades; 0% cadmium; IEC 60269-1 and -2

$196.37 /EA
NOT CURRENTLY IN STOCK

NH 1 250A 500V GG SGL

Item #: E218251

Supplier Part #: E218251
Brand: Mersen

The NH system is classified among plug-in fuse systems and is composed of , fuse-base (possibly including terminal covers and phase barriers) , fuse-link with blade contact , fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional. Type "gG" NH fuse-links are full range breaking capacity fuse-links and are used to protect cables and equipment. They can interrupt any current surge, from the lowest fusing current up to their breaking capacity, and so can be used alone as protection. They also protect electrical devices and industrial set-ups from the electrodynamic effects of very high short-circuit currents.

Lead free contact blades; VDE 0636 Part 201; Double indicator; Dimensions according to DIN 43 620 Parts 1 to 4; Isolated metal gripping lugs (SGL); IEC 60269-1 and -2; 0% cadmium

$224.27 /EA
NOT CURRENTLY IN STOCK

NH 1 250A 500V GG

Item #: E219815

Supplier Part #: E219815
Brand: Mersen

The NH system is classified among plug-in fuse systems and is composed of , fuse-base (possibly including terminal covers and phase barriers) , fuse-link with blade contact , fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional. Type "gG" NH fuse-links are full range breaking capacity fuse-links and are used to protect cables and equipment. They can interrupt any current surge, from the lowest fusing current up to their breaking capacity, and so can be used alone as protection. They also protect electrical devices and industrial set-ups from the electrodynamic effects of very high short-circuit currents.

0% cadmium; IEC 60269-1 and -2; VDE 0636 Part 201; Non-isolated gripping lugs; Dimensions according to DIN 43 620 parts 1 to 4; Double indicator; Lead free contact blades

$190.16 /EA
NOT CURRENTLY IN STOCK

NH 1 125A 690V GG

Item #: E228486

Supplier Part #: E228486
Brand: Mersen

The NH system is classified among plug-in fuse systems and is composed of , fuse-base (possibly including terminal covers and phase barriers) , fuse-link with blade contact , fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional. Type "gG" NH fuse-links are full range breaking capacity fuse-links and are used to protect cables and equipment. They can interrupt any current surge, from the lowest fusing current up to their breaking capacity, and so can be used alone as protection. They also protect electrical devices and industrial set-ups from the electrodynamic effects of very high short-circuit currents.

Double indicator; Dimensions according to DIN 43 620 parts 1 to 4; IEC 60269-1 and -2; Non-isolated gripping lugs; VDE 0636 Part 201; Lead free contact blades; 0% cadmium

$188.72 /EA
NOT CURRENTLY IN STOCK
NH 1 125A 500V AM

NH 1 125A 500V AM

Item #: E232511

Supplier Part #: E232511
Brand: Mersen

The NH system is classified among plug-in fuse systems and is composed of , fuse-base (possibly including terminal covers and phase barriers) , fuse-link with blade contact , fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional. Type "aM" NH fuse-links are partial-range breaking capacity fuse-links, used to protect motor circuits as they are strongly current-limiting and have low power losses. They interrupt currents from 6.3 times In up to their maximum breaking capacity and are therefore suited for short-circuit protection only. They must be associated with other switchgear for protection against overloads. These fuse-links can have a rated current equal to the motor's nominal current.

Non-isolated gripping lugs; Lead free contact blades; IEC 60269-1 and -2; VDE 0636 Part 201; Double indicator; 0% cadmium; Dimensions according to DIN 43 620 parts 1 to 4

$196.37 /EA
NOT CURRENTLY IN STOCK

NH 1 35A 690V AM

Item #: F227889

Supplier Part #: F227889
Brand: Mersen

The NH system is classified among plug-in fuse systems and is composed of , fuse-base (possibly including terminal covers and phase barriers) , fuse-link with blade contact , fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional. Type "aM" NH fuse-links are partial-range breaking capacity fuse-links, used to protect motor circuits as they are strongly current-limiting and have low power losses. They interrupt currents from 6.3 times In up to their maximum breaking capacity and are therefore suited for short-circuit protection only. They must be associated with other switchgear for protection against overloads. These fuse-links can have a rated current equal to the motor's nominal current.

Lead free contact blades; Double indicator; Non-isolated gripping lugs; 0% cadmium; IEC 60269-1 and -2; VDE 0636 Part 201; Dimensions according to DIN 43 620 parts 1 to 4

$188.72 /EA
NOT CURRENTLY IN STOCK