NH 000 4A 690V GG SGL

NH 000 4A 690V GG SGL

Item #: E229705

Supplier Part #: E229705
Brand: Mersen

The NH system is classified among plug-in fuse systems and is composed of , fuse-base (possibly including terminal covers and phase barriers) , fuse-link with blade contact , fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional. Type "gG" NH fuse-links are full range breaking capacity fuse-links and are used to protect cables and equipment. They can interrupt any current surge, from the lowest fusing current up to their breaking capacity, and so can be used alone as protection. They also protect electrical devices and industrial set-ups from the electrodynamic effects of very high short-circuit currents.

Dimensions according to DIN 43 620 Parts 1 to 4; Isolated metal gripping lugs (SGL); Lead free contact blades; VDE 0636 Part 201; 0% cadmium; Double indicator; IEC 60269-1 and -2

$135.70 /EA
NOT CURRENTLY IN STOCK

NH 1 160A 690V GG SGL

Item #: E229751

Supplier Part #: E229751
Brand: Mersen

The NH system is classified among plug-in fuse systems and is composed of , fuse-base (possibly including terminal covers and phase barriers) , fuse-link with blade contact , fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional. Type "gG" NH fuse-links are full range breaking capacity fuse-links and are used to protect cables and equipment. They can interrupt any current surge, from the lowest fusing current up to their breaking capacity, and so can be used alone as protection. They also protect electrical devices and industrial set-ups from the electrodynamic effects of very high short-circuit currents.

IEC 60269-1 and -2; Isolated metal gripping lugs (SGL); Dimensions according to DIN 43 620 Parts 1 to 4; Double indicator; Lead free contact blades; VDE 0636 Part 201; 0% cadmium

$207.70 /EA
NOT CURRENTLY IN STOCK
NH 000 16A 400V GG

NH 000 16A 400V GG

Item #: D223678

Supplier Part #: D223678
Brand: Mersen

The NH system is classified among plug-in fuse systems and is composed of , fuse-base (possibly including terminal covers and phase barriers) , fuse-link with blade contact , fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional. Type "gG" NH fuse-links are full range breaking capacity fuse-links and are used to protect cables and equipment. They can interrupt any current surge, from the lowest fusing current up to their breaking capacity, and so can be used alone as protection. They also protect electrical devices and industrial set-ups from the electrodynamic effects of very high short-circuit currents. Rated Power Dissipation values of Mersen NH fuse-links 400VAC are below the maximum values required by standard IEC 60269.

IEC 60269-1 and -2; Lead free contact blades; VDE 0636 Part 201; Double indicator; Non-isolated gripping lugs; Dimensions according to DIN 43 620 Parts 1 to 4; 0% cadmium

$130.06 /EA
NOT CURRENTLY IN STOCK

NH 000 100A 400V GG SGL

Item #: D223701

Supplier Part #: D223701
Brand: Mersen

The NH system is classified among plug-in fuse systems and is composed of , fuse-base (possibly including terminal covers and phase barriers) , fuse-link with blade contact , fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional. Type "gG" NH fuse-links are full range breaking capacity fuse-links and are used to protect cables and equipment. They can interrupt any current surge, from the lowest fusing current up to their breaking capacity, and so can be used alone as protection. They also protect electrical devices and industrial set-ups from the electrodynamic effects of very high short-circuit currents. Rated Power Dissipation values of Mersen NH fuse-links 400VAC are below the maximum values required by standard IEC 60269.

0% cadmium; Lead free contact blades; Dimensions according to DIN 43 620 Parts 1 to 4; Double indicator; IEC 60269-1 and -2; Isolated metal gripping lugs (SGL); VDE 0636 Part 201

$130.06 /EA
NOT CURRENTLY IN STOCK

NH 1 224A 400V GG SGL

Item #: D223724

Supplier Part #: D223724
Brand: Mersen

The NH system is classified among plug-in fuse systems and is composed of , fuse-base (possibly including terminal covers and phase barriers) , fuse-link with blade contact , fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional. Type "gG" NH fuse-links are full range breaking capacity fuse-links and are used to protect cables and equipment. They can interrupt any current surge, from the lowest fusing current up to their breaking capacity, and so can be used alone as protection. They also protect electrical devices and industrial set-ups from the electrodynamic effects of very high short-circuit currents. Rated Power Dissipation values of Mersen NH fuse-links 400VAC are below the maximum values required by standard IEC 60269.

Dimensions according to DIN 43 620 Parts 1 to 4; Lead free contact blades; VDE 0636 Part 201; 0% cadmium; IEC 60269-1 and -2; Isolated metal gripping lugs (SGL); Double indicator

$229.14 /EA
NOT CURRENTLY IN STOCK

NH 2 224A 400V GG SGL

Item #: D223747

Supplier Part #: D223747
Brand: Mersen

The NH system is classified among plug-in fuse systems and is composed of , fuse-base (possibly including terminal covers and phase barriers) , fuse-link with blade contact , fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional. Type "gG" NH fuse-links are full range breaking capacity fuse-links and are used to protect cables and equipment. They can interrupt any current surge, from the lowest fusing current up to their breaking capacity, and so can be used alone as protection. They also protect electrical devices and industrial set-ups from the electrodynamic effects of very high short-circuit currents. Rated Power Dissipation values of Mersen NH fuse-links 400VAC are below the maximum values required by standard IEC 60269.

VDE 0636 Part 201; Dimensions according to DIN 43 620 Parts 1 to 4; Double indicator; 0% cadmium; Lead free contact blades; Isolated metal gripping lugs (SGL); IEC 60269-1 and -2

$282.83 /EA
NOT CURRENTLY IN STOCK

NH 00 50A 690V AM

Item #: D227864

Supplier Part #: D227864
Brand: Mersen

The NH system is classified among plug-in fuse systems and is composed of , fuse-base (possibly including terminal covers and phase barriers) , fuse-link with blade contact , fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional. Type "aM" NH fuse-links are partial-range breaking capacity fuse-links, used to protect motor circuits as they are strongly current-limiting and have low power losses. They interrupt currents from 6.3 times In up to their maximum breaking capacity and are therefore suited for short-circuit protection only. They must be associated with other switchgear for protection against overloads. These fuse-links can have a rated current equal to the motor's nominal current.

VDE 0636 Part 201; Double indicator; Non-isolated gripping lugs; 0% cadmium; Dimensions according to DIN 43 620 parts 1 to 4; IEC 60269-1 and -2; Lead free contact blades

$123.54 /EA
NOT CURRENTLY IN STOCK

NH 1 25A 690V AM

Item #: D227887

Supplier Part #: D227887
Brand: Mersen

The NH system is classified among plug-in fuse systems and is composed of , fuse-base (possibly including terminal covers and phase barriers) , fuse-link with blade contact , fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional. Type "aM" NH fuse-links are partial-range breaking capacity fuse-links, used to protect motor circuits as they are strongly current-limiting and have low power losses. They interrupt currents from 6.3 times In up to their maximum breaking capacity and are therefore suited for short-circuit protection only. They must be associated with other switchgear for protection against overloads. These fuse-links can have a rated current equal to the motor's nominal current.

Lead free contact blades; Dimensions according to DIN 43 620 parts 1 to 4; 0% cadmium; VDE 0636 Part 201; Double indicator; IEC 60269-1 and -2; Non-isolated gripping lugs

$181.60 /EA
NOT CURRENTLY IN STOCK
NH 3 250A 690V AM

NH 3 250A 690V AM

Item #: D227979

Supplier Part #: D227979
Brand: Mersen

The NH system is classified among plug-in fuse systems and is composed of , fuse-base (possibly including terminal covers and phase barriers) , fuse-link with blade contact , fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional. Type "aM" NH fuse-links are partial-range breaking capacity fuse-links, used to protect motor circuits as they are strongly current-limiting and have low power losses. They interrupt currents from 6.3 times In up to their maximum breaking capacity and are therefore suited for short-circuit protection only. They must be associated with other switchgear for protection against overloads. These fuse-links can have a rated current equal to the motor's nominal current.

Lead free contact blades; 0% cadmium; IEC 60269-1 and -2; Double indicator; Non-isolated gripping lugs; Dimensions according to DIN 43 620 parts 1 to 4; VDE 0636 Part 201

$438.74 /EA
NOT CURRENTLY IN STOCK

NH 0 6A 690V GG

Item #: D228462

Supplier Part #: D228462
Brand: Mersen

The NH system is classified among plug-in fuse systems and is composed of , fuse-base (possibly including terminal covers and phase barriers) , fuse-link with blade contact , fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional. Type "gG" NH fuse-links are full range breaking capacity fuse-links and are used to protect cables and equipment. They can interrupt any current surge, from the lowest fusing current up to their breaking capacity, and so can be used alone as protection. They also protect electrical devices and industrial set-ups from the electrodynamic effects of very high short-circuit currents.

Double indicator; 0% cadmium; Dimensions according to DIN 43 620 parts 1 to 4; Lead free contact blades; Non-isolated gripping lugs; IEC 60269-1 and -2; VDE 0636 Part 201

$152.67 /EA
NOT CURRENTLY IN STOCK