NH 2 100A 500V GG SGL

Item #: N214165

Supplier Part #: N214165
Brand: Mersen

The NH system is classified among plug-in fuse systems and is composed of , fuse-base (possibly including terminal covers and phase barriers) , fuse-link with blade contact , fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional. Type "gG" NH fuse-links are full range breaking capacity fuse-links and are used to protect cables and equipment. They can interrupt any current surge, from the lowest fusing current up to their breaking capacity, and so can be used alone as protection. They also protect electrical devices and industrial set-ups from the electrodynamic effects of very high short-circuit currents.

Isolated metal gripping lugs (SGL); 0% cadmium; VDE 0636 Part 201; Lead free contact blades; Dimensions according to DIN 43 620 Parts 1 to 4; Double indicator; IEC 60269-1 and -2

$268.32 /EA
NOT CURRENTLY IN STOCK

NH 2 50A 690V AM

Item #: N227965

Supplier Part #: N227965
Brand: Mersen

The NH system is classified among plug-in fuse systems and is composed of , fuse-base (possibly including terminal covers and phase barriers) , fuse-link with blade contact , fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional. Type "aM" NH fuse-links are partial-range breaking capacity fuse-links, used to protect motor circuits as they are strongly current-limiting and have low power losses. They interrupt currents from 6.3 times In up to their maximum breaking capacity and are therefore suited for short-circuit protection only. They must be associated with other switchgear for protection against overloads. These fuse-links can have a rated current equal to the motor's nominal current.

IEC 60269-1 and -2; Lead free contact blades; Non-isolated gripping lugs; Double indicator; Dimensions according to DIN 43 620 parts 1 to 4; 0% cadmium; VDE 0636 Part 201

$246.68 /EA
NOT CURRENTLY IN STOCK

NH 2 80A 690V GG

Item #: N228494

Supplier Part #: N228494
Brand: Mersen

The NH system is classified among plug-in fuse systems and is composed of , fuse-base (possibly including terminal covers and phase barriers) , fuse-link with blade contact , fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional. Type "gG" NH fuse-links are full range breaking capacity fuse-links and are used to protect cables and equipment. They can interrupt any current surge, from the lowest fusing current up to their breaking capacity, and so can be used alone as protection. They also protect electrical devices and industrial set-ups from the electrodynamic effects of very high short-circuit currents.

IEC 60269-1 and -2; Lead free contact blades; Non-isolated gripping lugs; Dimensions according to DIN 43 620 parts 1 to 4; Double indicator; 0% cadmium; VDE 0636 Part 201

$242.32 /EA
NOT CURRENTLY IN STOCK

6,9 URD 2PV 0200

Item #: N320471

Supplier Part #: N320471
Brand: Mersen

The 690/700V Protistor® fuse-links provide maximum flexibility in equipment design and ultimate protection for today's power conversion equipment. These NH style fuse-links are defined as per DIN 43620/00 for a worldwide acceptance into NH modular system fuse-holders, fuse switch disconnectors for direct installation. The Protistor® have been engineered to provide state-of-the-art protection for semiconductors diodes, thyristors, GTO's and IGBT devices. Fuses are assembled with pure silver, die-cut elements embedded in solidified sand, which helps control arcing characteristics for a lower I²t and high interrupting rating level. All contact surfaces are silver plated and all hardware is non-magnetic. Each fuse-link can be equipped with a low voltage trip-indicator which can operate a field mountable microswitch.

aR Class according to VDE 636-23 and IEC 60269-4; IEC 60269-4 Compliance; Multiple body sizes; Superior cycling capability; UL/CSA Recognized Component; Very low I²t for improved semiconductor protection; Current limiting; Indication system with double indicator; Ultra fast acting

$997.15 /EA
NOT CURRENTLY IN STOCK
NH 2 50A 690V GG SGL

NH 2 50A 690V GG SGL

Item #: P229760

Supplier Part #: P229760
Brand: Mersen

The NH system is classified among plug-in fuse systems and is composed of , fuse-base (possibly including terminal covers and phase barriers) , fuse-link with blade contact , fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional. Type "gG" NH fuse-links are full range breaking capacity fuse-links and are used to protect cables and equipment. They can interrupt any current surge, from the lowest fusing current up to their breaking capacity, and so can be used alone as protection. They also protect electrical devices and industrial set-ups from the electrodynamic effects of very high short-circuit currents.

IEC 60269-1 and -2; VDE 0636 Part 201; 0% cadmium; Dimensions according to DIN 43 620 Parts 1 to 4; Isolated metal gripping lugs (SGL); Double indicator; Lead free contact blades

$277.09 /EA
NOT CURRENTLY IN STOCK
690V NH2 C/P gG 125A

690V NH2 C/P gG 125A

Item #: W212102

Supplier Part #: W212102
Brand: Mersen

The NH system is classified among plug-in fuse systems and is composed of , fuse-base (possibly including terminal covers and phase barriers) , fuse-link with blade contact , fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional. Type "gG" NH fuse-links are full range breaking capacity fuse-links and are used to protect cables and equipment. They can interrupt any current surge, from the lowest fusing current up to their breaking capacity, and so can be used alone as protection. They also protect electrical devices and industrial set-ups from the electrodynamic effects of very high short-circuit currents.

VDE 0636 Part 201; Dimensions according to DIN 43 620 Parts 1 to 4; Lead free contact blades; IEC 60269-1 and -2; 0% cadmium

$316.12 /EA
NOT CURRENTLY IN STOCK
500V NH2 C/P gG 500A

500V NH2 C/P gG 500A

Item #: W217208

Supplier Part #: W217208
Brand: Mersen

The NH system is classified among plug-in fuse systems and is composed of , fuse-base (possibly including terminal covers and phase barriers) , fuse-link with blade contact , fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional. Type "gG" NH fuse-links are full range breaking capacity fuse-links and are used to protect cables and equipment. They can interrupt any current surge, from the lowest fusing current up to their breaking capacity, and so can be used alone as protection. They also protect electrical devices and industrial set-ups from the electrodynamic effects of very high short-circuit currents.

VDE 0636 Part 201; Dimensions according to DIN 43 620 Parts 1 to 4; 0% cadmium; IEC 60269-1 and -2; Lead free contact blades

$504.69 /EA
NOT CURRENTLY IN STOCK

NH 2 250A 690V AM

Item #: X227973

Supplier Part #: X227973
Brand: Mersen

The NH system is classified among plug-in fuse systems and is composed of , fuse-base (possibly including terminal covers and phase barriers) , fuse-link with blade contact , fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional. Type "aM" NH fuse-links are partial-range breaking capacity fuse-links, used to protect motor circuits as they are strongly current-limiting and have low power losses. They interrupt currents from 6.3 times In up to their maximum breaking capacity and are therefore suited for short-circuit protection only. They must be associated with other switchgear for protection against overloads. These fuse-links can have a rated current equal to the motor's nominal current.

IEC 60269-1 and -2; Double indicator; Dimensions according to DIN 43 620 parts 1 to 4; VDE 0636 Part 201; Non-isolated gripping lugs; Lead free contact blades; 0% cadmium

$274.47 /EA
NOT CURRENTLY IN STOCK

6,9 URD 2PV 0315

Item #: X320479

Supplier Part #: X320479
Brand: Mersen

The 690/700V Protistor® fuse-links provide maximum flexibility in equipment design and ultimate protection for today's power conversion equipment. These NH style fuse-links are defined as per DIN 43620/00 for a worldwide acceptance into NH modular system fuse-holders, fuse switch disconnectors for direct installation. The Protistor® have been engineered to provide state-of-the-art protection for semiconductors diodes, thyristors, GTO's and IGBT devices. Fuses are assembled with pure silver, die-cut elements embedded in solidified sand, which helps control arcing characteristics for a lower I²t and high interrupting rating level. All contact surfaces are silver plated and all hardware is non-magnetic. Each fuse-link can be equipped with a low voltage trip-indicator which can operate a field mountable microswitch.

Very low I²t for improved semiconductor protection; aR Class according to VDE 636-23 and IEC 60269-4; UL/CSA Recognized Component; Ultra fast acting; Current limiting; Multiple body sizes; Indication system with double indicator; Superior cycling capability; IEC 60269-4 Compliance

$1,145.48 /EA
NOT CURRENTLY IN STOCK

NH 2 100A 400V GG SGL

Item #: Y223742

Supplier Part #: Y223742
Brand: Mersen

The NH system is classified among plug-in fuse systems and is composed of , fuse-base (possibly including terminal covers and phase barriers) , fuse-link with blade contact , fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional. Type "gG" NH fuse-links are full range breaking capacity fuse-links and are used to protect cables and equipment. They can interrupt any current surge, from the lowest fusing current up to their breaking capacity, and so can be used alone as protection. They also protect electrical devices and industrial set-ups from the electrodynamic effects of very high short-circuit currents. Rated Power Dissipation values of Mersen NH fuse-links 400VAC are below the maximum values required by standard IEC 60269.

IEC 60269-1 and -2; Double indicator; 0% cadmium; VDE 0636 Part 201; Dimensions according to DIN 43 620 Parts 1 to 4; Isolated metal gripping lugs (SGL); Lead free contact blades

$266.73 /EA