Browse Categories

Search in Category

Fuses

Search Filters

  • NH2 x

Filter Your Search

Show Attribute Brand
Hide Attribute Voltage

Shop by Category

Loading...

Fuses

Power Products/Fuses 
Viewing Page 2 of 16 (151 results)
FUS. AM NH2 C/P 160A

FUS. AM NH2 C/P 160A

Item #: B201849

Supplier Part #: B201849
Brand: Mersen

The NH system is classified among plug-in fuse systems and is composed of , fuse-base (possibly including terminal covers and phase barriers) , fuse-link with blade contact , fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current, it must be handled by a qualified professional.

IEC 60269-1 and -2; VDE 0636 Part 201; 0% cadmium; Lead free contact blades; Dimensions according to DIN 43 620 Parts 1 to 4

$326.63 /EA
NOT CURRENTLY IN STOCK

NH 2 400A 500V GG SGL

Item #: B211601

Supplier Part #: B211601
Brand: Mersen

The NH system is classified among plug-in fuse systems and is composed of , fuse-base (possibly including terminal covers and phase barriers) , fuse-link with blade contact , fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional. Type "gG" NH fuse-links are full range breaking capacity fuse-links and are used to protect cables and equipment. They can interrupt any current surge, from the lowest fusing current up to their breaking capacity, and so can be used alone as protection. They also protect electrical devices and industrial set-ups from the electrodynamic effects of very high short-circuit currents.

IEC 60269-1 and -2; Dimensions according to DIN 43 620 parts 1 to 4; Double indicator; 0% cadmium; Lead free contact blades; VDE 0636 Part 201; Non-isolated gripping lugs

$232.78 /EA
NOT CURRENTLY IN STOCK

BASE NH 2-PP F/TORN. 3P

Item #: B212107

Supplier Part #: B212107
Brand: Mersen

NH fuse-bases are available for delivery in single-pole and three-pole designs and can be closely mounted in parallel rows. Each three-pole base is upplied with two phase-partition walls. NH fuse-links plugon covers which clip onto the contact springs can also be supplied for these bases. Plastic fuse-bases sizes 00 to 3 have a single-part plastic base while size 4 has a metal baseplate with 2 ceramic bases. The stable silver-plated contact springs are made of electrolytic copper and formed from one piece. Separate springing is provided by highly resilient captive steel springs, making the contact invulnerable to high thermal stress. Size 4 NH fuse-bases are designed for size 4 fuse-links with 8 mm contact blades. A microswitch (250VAC/10A, terminal size 6.3x0.8mm) can be used with NH fuse-links with striker, it operates when fuse melts or where there is no fuse-link. Indirect touch protection fuse bases no microswitch possible. Rated impulse withstand voltage Uimp 6kV / 8kV (sizes 00 / 0-4)

Polyamide insulating bases; Dimensions in accordance with DIN 43620; High-pressure spring contacts; DIN VDE 0636-2, 0636-21; Multipolar bases possible by direct linkage in 00 size and with separator accessory in sizes 0, 1, 2 and 3; Screw or rail mounting; Silver-plated contacts; IEC 60269 Compliance

$841.93 /EA
NOT CURRENTLY IN STOCK

NH 2 160A 400V GG SGL

Item #: B223745

Supplier Part #: B223745
Brand: Mersen

The NH system is classified among plug-in fuse systems and is composed of , fuse-base (possibly including terminal covers and phase barriers) , fuse-link with blade contact , fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional. Type "gG" NH fuse-links are full range breaking capacity fuse-links and are used to protect cables and equipment. They can interrupt any current surge, from the lowest fusing current up to their breaking capacity, and so can be used alone as protection. They also protect electrical devices and industrial set-ups from the electrodynamic effects of very high short-circuit currents. Rated Power Dissipation values of Mersen NH fuse-links 400VAC are below the maximum values required by standard IEC 60269.

Lead free contact blades; Dimensions according to DIN 43 620 Parts 1 to 4; Double indicator; VDE 0636 Part 201; IEC 60269-1 and -2; Isolated metal gripping lugs (SGL); 0% cadmium

$282.83 /EA
NOT CURRENTLY IN STOCK

NH 2 400A 690V AM

Item #: B227977

Supplier Part #: B227977
Brand: Mersen

The NH system is classified among plug-in fuse systems and is composed of , fuse-base (possibly including terminal covers and phase barriers) , fuse-link with blade contact , fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional. Type "aM" NH fuse-links are partial-range breaking capacity fuse-links, used to protect motor circuits as they are strongly current-limiting and have low power losses. They interrupt currents from 6.3 times In up to their maximum breaking capacity and are therefore suited for short-circuit protection only. They must be associated with other switchgear for protection against overloads. These fuse-links can have a rated current equal to the motor's nominal current.

IEC 60269-1 and -2; Dimensions according to DIN 43 620 parts 1 to 4; Non-isolated gripping lugs; VDE 0636 Part 201; Lead free contact blades; Double indicator; 0% cadmium

$276.88 /EA
NOT CURRENTLY IN STOCK

6,9 URD 2PV 0400

Item #: B320483

Supplier Part #: B320483
Brand: Mersen

The 690/700V Protistor® fuse-links provide maximum flexibility in equipment design and ultimate protection for today's power conversion equipment. These NH style fuse-links are defined as per DIN 43620/00 for a worldwide acceptance into NH modular system fuse-holders, fuse switch disconnectors for direct installation. The Protistor® have been engineered to provide state-of-the-art protection for semiconductors diodes, thyristors, GTO's and IGBT devices. Fuses are assembled with pure silver, die-cut elements embedded in solidified sand, which helps control arcing characteristics for a lower I²t and high interrupting rating level. All contact surfaces are silver plated and all hardware is non-magnetic. Each fuse-link can be equipped with a low voltage trip-indicator which can operate a field mountable microswitch.

aR Class according to VDE 636-23 and IEC 60269-4; Current limiting; UL/CSA Recognized Component; Superior cycling capability; Ultra fast acting; Multiple body sizes; Indication system with double indicator; Very low I²t for improved semiconductor protection; IEC 60269-4 Compliance

$1,090.91 /EA
NOT CURRENTLY IN STOCK

NH 2 224A 400V GG SGL

Item #: D223747

Supplier Part #: D223747
Brand: Mersen

The NH system is classified among plug-in fuse systems and is composed of , fuse-base (possibly including terminal covers and phase barriers) , fuse-link with blade contact , fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional. Type "gG" NH fuse-links are full range breaking capacity fuse-links and are used to protect cables and equipment. They can interrupt any current surge, from the lowest fusing current up to their breaking capacity, and so can be used alone as protection. They also protect electrical devices and industrial set-ups from the electrodynamic effects of very high short-circuit currents. Rated Power Dissipation values of Mersen NH fuse-links 400VAC are below the maximum values required by standard IEC 60269.

VDE 0636 Part 201; Dimensions according to DIN 43 620 Parts 1 to 4; Double indicator; 0% cadmium; Lead free contact blades; Isolated metal gripping lugs (SGL); IEC 60269-1 and -2

$282.83 /EA
NOT CURRENTLY IN STOCK
NH 2 250A 690V GG SGL

NH 2 250A 690V GG SGL

Item #: D233729

Supplier Part #: D233729
Brand: Mersen

The NH system is classified among plug-in fuse systems and is composed of , fuse-base (possibly including terminal covers and phase barriers) , fuse-link with blade contact , fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional. Type "gG" NH fuse-links are full range breaking capacity fuse-links and are used to protect cables and equipment. They can interrupt any current surge, from the lowest fusing current up to their breaking capacity, and so can be used alone as protection. They also protect electrical devices and industrial set-ups from the electrodynamic effects of very high short-circuit currents.

Dimensions according to DIN 43 620 Parts 1 to 4; IEC 60269-1 and -2; Lead free contact blades; VDE 0636 Part 201; Double indicator; Isolated metal gripping lugs (SGL); 0% cadmium

$316.78 /EA
NOT CURRENTLY IN STOCK
500V NH2 C/P gG 355A

500V NH2 C/P gG 355A

Item #: E215675

Supplier Part #: E215675
Brand: Mersen

The NH system is classified among plug-in fuse systems and is composed of , fuse-base (possibly including terminal covers and phase barriers) , fuse-link with blade contact , fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional. Type "gG" NH fuse-links are full range breaking capacity fuse-links and are used to protect cables and equipment. They can interrupt any current surge, from the lowest fusing current up to their breaking capacity, and so can be used alone as protection. They also protect electrical devices and industrial set-ups from the electrodynamic effects of very high short-circuit currents.

Dimensions according to DIN 43 620 Parts 1 to 4; IEC 60269-1 and -2; VDE 0636 Part 201; Lead free contact blades; 0% cadmium

$316.12 /EA
NOT CURRENTLY IN STOCK

NH 2 250A 400V GG SGL

Item #: E223748

Supplier Part #: E223748
Brand: Mersen

The NH system is classified among plug-in fuse systems and is composed of , fuse-base (possibly including terminal covers and phase barriers) , fuse-link with blade contact , fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional. Type "gG" NH fuse-links are full range breaking capacity fuse-links and are used to protect cables and equipment. They can interrupt any current surge, from the lowest fusing current up to their breaking capacity, and so can be used alone as protection. They also protect electrical devices and industrial set-ups from the electrodynamic effects of very high short-circuit currents. Rated Power Dissipation values of Mersen NH fuse-links 400VAC are below the maximum values required by standard IEC 60269.

Double indicator; Lead free contact blades; Dimensions according to DIN 43 620 Parts 1 to 4; Isolated metal gripping lugs (SGL); VDE 0636 Part 201; 0% cadmium; IEC 60269-1 and -2

$282.83 /EA
NOT CURRENTLY IN STOCK
  • « PREV
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • NEXT »