Search in Category
Search Filters
-
1.06 in x
Filter Your Search
Shop by Category
Fuses
600V 50A RK1 TD FUSE
Disconnects; Extremely current-limiting for low peak let-thru current; Solid state SmartSpot visual blown fuse indicator; Time-delay for motor starting and transformer inrush currents without nuisance opening; Easy 2-to-1 selectivity for prevention of nuisance shut downs and “black outs”; Rejection-style design prevents replacement errors (when used with recommended fuse blocks); All general-purpose circuits; CSA certified to standard C22.2 No. 248.12; Metal-embossed date and catalog number for easier traceability and lasting identification; DC listed to UL standard 248; Recommended for Arc Flash energy reduction; Reduced inventory by taking the place of class RK5, K, and H fuses; Motors; Branch circuit protection; Safety switches; Transformers; UL listed to standard 248-12 File E2137; Fiberglass body provides dimensional stability in harsh industrial settings; High-visibility orange label gives instant brand recognition; Control panels; 300kA interrupting rating – self-certified, UL witnessed tests; 600VAC & 600VDC dual rated
600V 35A RK1 FUSE
Feeder circuits; CSA certified to standard C22.2 No. 248.12; Self-certified for DC per UL248; High degree of current limitation for low peak let-thru current; Fiberglass body provides dimensional stability in harsh industrial environments; UL listed to standard 248-12 File E2137; Easy-to-read imprint label for quick recognition and replacement; Rejection style design prevents replacement by other fuse classes; Switchboards; Bus duct; Lighting circuits; Load centers; Panelboards; Non-inductive loads
600V 40A RK1 FUSE
CSA certified to standard C22.2 No. 248.12; UL listed to standard 248-12 File E2137; Switchboards; Panelboards; Easy-to-read imprint label for quick recognition and replacement; Non-inductive loads; Rejection style design prevents replacement by other fuse classes; Self-certified for DC per UL248; Load centers; High degree of current limitation for low peak let-thru current; Feeder circuits; Lighting circuits; Bus duct; Fiberglass body provides dimensional stability in harsh industrial environments
90480-FUSE,FORM 600
DC Tested to UL248-1 (1-600A); UL Recognized Component File E60314
500V 35A DC SPECIAL FUSE
UL Recognized Component File E60314; DC Tested to UL248-1 (1-600A)
90303-FUSE,FORM 600
UL Recognized Component File E60314; DC Tested to UL248-1 (1-600A)
500V 40A DC SPECIAL FUSE
DC Tested to UL248-1 (1-600A); UL Recognized Component File E60314
90304-FUSE,FORM 600
DC Tested to UL248-1 (1-600A); UL Recognized Component File E60314
500V 45A DC SPECIAL FUSE
DC Tested to UL248-1 (1-600A); UL Recognized Component File E60314
90305-FUSE,FORM 600
UL Recognized Component File E60314; DC Tested to UL248-1 (1-600A)