600V 60A RK1 TD FUSE
Branch circuit protection; Recommended for Arc Flash energy reduction; High-visibility orange label gives instant brand recognition; DC listed to UL standard 248; Transformers; Metal-embossed date and catalog number for easier traceability and lasting identification; Solid state SmartSpot visual blown fuse indicator; Disconnects; Time-delay for motor starting and transformer inrush currents without nuisance opening; Rejection-style design prevents replacement errors (when used with recommended fuse blocks); Fiberglass body provides dimensional stability in harsh industrial settings; 600VAC & 600VDC dual rated; 300kA interrupting rating – self-certified, UL witnessed tests; Reduced inventory by taking the place of class RK5, K, and H fuses; All general-purpose circuits; Easy 2-to-1 selectivity for prevention of nuisance shut downs and “black outs”; Safety switches; CSA certified to standard C22.2 No. 248.12; Control panels; UL listed to standard 248-12 File E2137; Extremely current-limiting for low peak let-thru current; Motors
600V 60A 5 1/2x1 1/16 TD
CSA certified to standard C22.2 no. 248.12; Time-delay for motor start-ups and transformer inrush currents without nuisance opening; UL listed to standard 248-12 File E2137; Transformers; Time-delay; Optional solid state SmartSpot blown fuse indicator; General-purpose equipment; Current-limiting for low peak let-thru current; AC & DC rated; Current-limiting; Fiberglass body provides dimensional stability in harsh industrial settings; Rejection-style design prevents replacement errors (when used with recommended fuse blocks); DC listed to UL standard 248 TRS only; Mains; Service entrance equipment; Branch circuits; Metal-embossed date and catalog number for traceability and lasting identification; High-grade silica filler ensures fast arc quenching and high current limitation; Motor circuits; Feeders; Easy-to-read label for quick brand recognition and replacement
600V 40A 5 1/2x1 1/16 TD
Service entrance equipment; Mains; Optional solid state SmartSpot blown fuse indicator; UL listed to standard 248-12 File E2137; DC listed to UL standard 248 TRS only; Metal-embossed date and catalog number for traceability and lasting identification; Easy-to-read label for quick brand recognition and replacement; AC & DC rated; Fiberglass body provides dimensional stability in harsh industrial settings; Current-limiting for low peak let-thru current; General-purpose equipment; Branch circuits; High-grade silica filler ensures fast arc quenching and high current limitation; CSA certified to standard C22.2 no. 248.12; Time-delay for motor start-ups and transformer inrush currents without nuisance opening; Transformers; Motor circuits; Rejection-style design prevents replacement errors (when used with recommended fuse blocks); Time-delay; Feeders; Current-limiting
H FUSE 600V 60A NRS
Non-time delay; Type “P” (15 – 60A); 250V and 600V applications
600V 40A 5 1/2x1 1/16 K5 FUSE
Residential and small commercial installations; UL Listed to Standard 248-9 File E2137; Self-certified for DC per UL248; Branch circuits; CSA Certified to Standard C22.2 No. 248.9 (The Canadian Electrical Code requires these fuses in ratings 15 through 60A to be of the low melting point design; use OTN 15-60.); Resistive heating; Low cost for high protection value; Feeders; Easy to read imprint label for quick recognition and replacement
600V 50A 5 1/2x1 1/16 K5 FUSE
Feeders; Low cost for high protection value; Easy to read imprint label for quick recognition and replacement; Branch circuits; CSA Certified to Standard C22.2 No. 248.9 (The Canadian Electrical Code requires these fuses in ratings 15 through 60A to be of the low melting point design; use OTN 15-60.); Resistive heating; UL Listed to Standard 248-9 File E2137; Residential and small commercial installations; Self-certified for DC per UL248
600V 60A 5 1/2x1 1/16 K5 FUSE
Self-certified for DC per UL248; Branch circuits; Easy to read imprint label for quick recognition and replacement; Feeders; Residential and small commercial installations; CSA Certified to Standard C22.2 No. 248.9 (The Canadian Electrical Code requires these fuses in ratings 15 through 60A to be of the low melting point design; use OTN 15-60.); Resistive heating; UL Listed to Standard 248-9 File E2137; Low cost for high protection value
600V 45A RK1 FUSE
Load centers; Self-certified for DC per UL248; UL listed to standard 248-12 File E2137; High degree of current limitation for low peak let-thru current; Switchboards; Non-inductive loads; Bus duct; Feeder circuits; Fiberglass body provides dimensional stability in harsh industrial environments; Easy-to-read imprint label for quick recognition and replacement; Panelboards; CSA certified to standard C22.2 No. 248.12; Rejection style design prevents replacement by other fuse classes; Lighting circuits
600V 50A RK1 FUSE
Fiberglass body provides dimensional stability in harsh industrial environments; Switchboards; Feeder circuits; Panelboards; UL listed to standard 248-12 File E2137; Rejection style design prevents replacement by other fuse classes; Self-certified for DC per UL248; Lighting circuits; High degree of current limitation for low peak let-thru current; Easy-to-read imprint label for quick recognition and replacement; Bus duct; Non-inductive loads; CSA certified to standard C22.2 No. 248.12; Load centers
600V 60A RK1 FUSE
Feeder circuits; Panelboards; Switchboards; Bus duct; Non-inductive loads; CSA certified to standard C22.2 No. 248.12; Fiberglass body provides dimensional stability in harsh industrial environments; Rejection style design prevents replacement by other fuse classes; Easy-to-read imprint label for quick recognition and replacement; UL listed to standard 248-12 File E2137; Lighting circuits; Self-certified for DC per UL248; Load centers; High degree of current limitation for low peak let-thru current