Browse Categories

Search in Category

Fuses

Search Filters

  • 5 in x

Shop by Category

Loading...

Fuses

Power Products/Fuses 
Viewing Page 9 of 17 (166 results)
74895-FUSE TRIONIC

74895-FUSE TRIONIC

Item #: TRS15RDC

Supplier Part #: TRS15RDC
Brand: Mersen

Tri-OnicĀ® TRS-RDC time-delay fuse is designed for DC circuit protection in surface and underground mines. The TRS-RDC is MSHA approved and meets the industry's most severe third party requirements for 600VDC rated fuses.

Rail heaters; Pump motors; MSHA approval no. 28-26-0; DC rated for mine duty and other long time-constant applications; Mine circuits; Trailing cables; Rugged glass melamine body for superior reliability in harsh environments; Time-delay for motor start-ups and high inrush loads without nuisance opening

$25.82 /EA
NOT CURRENTLY IN STOCK
600V 15A TD RK5 FUSE SMARTSPOT

600V 15A TD RK5 FUSE SMARTSPOT

Item #: TRS15RID

Supplier Part #: TRS15RID
Brand: Mersen

Tri-Onic TRS-R current-limiting time-delay fuses are engineered for overcurrent protection of motors, transformers, service entrance equipment, feeders and branch-circuits. The time-delay characteristics of the TRS-R safely handle harmless starting currents and inrush currents associated with today's motors and transformers.

Motor circuits; Feeders; Transformers; General-purpose equipment; UL listed to standard 248-12 File E2137; Branch circuits; High-grade silica filler ensures fast arc quenching and high current limitation; Optional solid state SmartSpot blown fuse indicator; Easy-to-read label for quick brand recognition and replacement; Rejection-style design prevents replacement errors (when used with recommended fuse blocks); Current-limiting; Time-delay; Mains; Fiberglass body provides dimensional stability in harsh industrial settings; Metal-embossed date and catalog number for traceability and lasting identification; DC listed to UL standard 248 TRS only; Current-limiting for low peak let-thru current; Time-delay for motor start-ups and transformer inrush currents without nuisance opening; CSA certified to standard C22.2 no. 248.12; Service entrance equipment; AC & DC rated

$24.63 /EA
NOT CURRENTLY IN STOCK
600V 17 1/2A 5x13/16 TD FUSE

600V 17 1/2A 5x13/16 TD FUSE

Item #: TRS17-1/2R

Supplier Part #: TRS17-1/2R
Brand: Mersen

Tri-Onic TRS-R current-limiting time-delay fuses are engineered for overcurrent protection of motors, transformers, service entrance equipment, feeders and branch-circuits. The time-delay characteristics of the TRS-R safely handle harmless starting currents and inrush currents associated with today's motors and transformers.

Current-limiting; Optional solid state SmartSpot blown fuse indicator; Rejection-style design prevents replacement errors (when used with recommended fuse blocks); Time-delay; Time-delay for motor start-ups and transformer inrush currents without nuisance opening; Service entrance equipment; Motor circuits; DC listed to UL standard 248 TRS only; General-purpose equipment; High-grade silica filler ensures fast arc quenching and high current limitation; Current-limiting for low peak let-thru current; Fiberglass body provides dimensional stability in harsh industrial settings; Transformers; Feeders; Branch circuits; AC & DC rated; UL listed to standard 248-12 File E2137; Easy-to-read label for quick brand recognition and replacement; Metal-embossed date and catalog number for traceability and lasting identification; CSA certified to standard C22.2 no. 248.12; Mains

$23.68 /EA
NOT CURRENTLY IN STOCK
74896-FUSE TRIONIC

74896-FUSE TRIONIC

Item #: TRS17-1/2RDC

Supplier Part #: TRS17-1/2RDC
Brand: Mersen

Tri-OnicĀ® TRS-RDC time-delay fuse is designed for DC circuit protection in surface and underground mines. The TRS-RDC is MSHA approved and meets the industry's most severe third party requirements for 600VDC rated fuses.

Trailing cables; DC rated for mine duty and other long time-constant applications; Rail heaters; Mine circuits; Rugged glass melamine body for superior reliability in harsh environments; MSHA approval no. 28-26-0; Time-delay for motor start-ups and high inrush loads without nuisance opening; Pump motors

$25.82 /EA
NOT CURRENTLY IN STOCK
600V 17-1/2A TD RK5 FUSE SMART

600V 17-1/2A TD RK5 FUSE SMART

Item #: TRS17-1/2RID

Supplier Part #: TRS17-1/2RID
Brand: Mersen

Tri-Onic TRS-R current-limiting time-delay fuses are engineered for overcurrent protection of motors, transformers, service entrance equipment, feeders and branch-circuits. The time-delay characteristics of the TRS-R safely handle harmless starting currents and inrush currents associated with today's motors and transformers.

Rejection-style design prevents replacement errors (when used with recommended fuse blocks); Metal-embossed date and catalog number for traceability and lasting identification; Mains; High-grade silica filler ensures fast arc quenching and high current limitation; Optional solid state SmartSpot blown fuse indicator; Current-limiting for low peak let-thru current; Branch circuits; Motor circuits; DC listed to UL standard 248 TRS only; Easy-to-read label for quick brand recognition and replacement; Time-delay for motor start-ups and transformer inrush currents without nuisance opening; UL listed to standard 248-12 File E2137; Feeders; General-purpose equipment; Time-delay; AC & DC rated; CSA certified to standard C22.2 no. 248.12; Fiberglass body provides dimensional stability in harsh industrial settings; Service entrance equipment; Transformers; Current-limiting

$24.63 /EA
NOT CURRENTLY IN STOCK
600V 1A 5x13/16 TD FUSE

600V 1A 5x13/16 TD FUSE

Item #: TRS1R

Supplier Part #: TRS1R
Brand: Mersen

Tri-Onic TRS-R current-limiting time-delay fuses are engineered for overcurrent protection of motors, transformers, service entrance equipment, feeders and branch-circuits. The time-delay characteristics of the TRS-R safely handle harmless starting currents and inrush currents associated with today's motors and transformers.

Rejection-style design prevents replacement errors (when used with recommended fuse blocks); Motor circuits; DC listed to UL standard 248 TRS only; AC & DC rated; Easy-to-read label for quick brand recognition and replacement; Time-delay for motor start-ups and transformer inrush currents without nuisance opening; CSA certified to standard C22.2 no. 248.12; Current-limiting for low peak let-thru current; Mains; Optional solid state SmartSpot blown fuse indicator; Branch circuits; High-grade silica filler ensures fast arc quenching and high current limitation; Transformers; Feeders; Service entrance equipment; Fiberglass body provides dimensional stability in harsh industrial settings; General-purpose equipment; Time-delay; Current-limiting; Metal-embossed date and catalog number for traceability and lasting identification; UL listed to standard 248-12 File E2137

$30.36 /EA
NOT CURRENTLY IN STOCK
RK5 TD DC FUSE 300V 1A TRS

RK5 TD DC FUSE 300V 1A TRS

Item #: TRS1RDC

Supplier Part #: TRS1RDC
Brand: Mersen

Tri-OnicĀ® TRS-RDC time-delay fuse is designed for DC circuit protection in surface and underground mines. The TRS-RDC is MSHA approved and meets the industry's most severe third party requirements for 600VDC rated fuses.

Trailing cables; Rugged glass melamine body for superior reliability in harsh environments; Pump motors; Time-delay for motor start-ups and high inrush loads without nuisance opening; Mine circuits; Rail heaters; MSHA approval no. 28-26-0; DC rated for mine duty and other long time-constant applications

$32.75 /EA
NOT CURRENTLY IN STOCK
600V 2 1/2A 5x13/16 TD FUSE

600V 2 1/2A 5x13/16 TD FUSE

Item #: TRS2-1/2R

Supplier Part #: TRS2-1/2R
Brand: Mersen

Tri-Onic TRS-R current-limiting time-delay fuses are engineered for overcurrent protection of motors, transformers, service entrance equipment, feeders and branch-circuits. The time-delay characteristics of the TRS-R safely handle harmless starting currents and inrush currents associated with today's motors and transformers.

Current-limiting; CSA certified to standard C22.2 no. 248.12; AC & DC rated; Rejection-style design prevents replacement errors (when used with recommended fuse blocks); Time-delay for motor start-ups and transformer inrush currents without nuisance opening; Branch circuits; Optional solid state SmartSpot blown fuse indicator; Fiberglass body provides dimensional stability in harsh industrial settings; Time-delay; General-purpose equipment; Easy-to-read label for quick brand recognition and replacement; Mains; Metal-embossed date and catalog number for traceability and lasting identification; Feeders; DC listed to UL standard 248 TRS only; Transformers; UL listed to standard 248-12 File E2137; High-grade silica filler ensures fast arc quenching and high current limitation; Motor circuits; Current-limiting for low peak let-thru current; Service entrance equipment

$30.36 /EA
NOT CURRENTLY IN STOCK
RK5 TD DC FUSE 300V 2-1/2A TRS

RK5 TD DC FUSE 300V 2-1/2A TRS

Item #: TRS2-1/2RDC

Supplier Part #: TRS2-1/2RDC
Brand: Mersen

Tri-OnicĀ® TRS-RDC time-delay fuse is designed for DC circuit protection in surface and underground mines. The TRS-RDC is MSHA approved and meets the industry's most severe third party requirements for 600VDC rated fuses.

Rail heaters; Time-delay for motor start-ups and high inrush loads without nuisance opening; Rugged glass melamine body for superior reliability in harsh environments; MSHA approval no. 28-26-0; Trailing cables; Mine circuits; DC rated for mine duty and other long time-constant applications; Pump motors

$32.75 /EA
NOT CURRENTLY IN STOCK
600V 2 1/4A 5x13/16 TD FUSE

600V 2 1/4A 5x13/16 TD FUSE

Item #: TRS2-1/4R

Supplier Part #: TRS2-1/4R
Brand: Mersen

Tri-Onic TRS-R current-limiting time-delay fuses are engineered for overcurrent protection of motors, transformers, service entrance equipment, feeders and branch-circuits. The time-delay characteristics of the TRS-R safely handle harmless starting currents and inrush currents associated with today's motors and transformers.

Optional solid state SmartSpot blown fuse indicator; Mains; Current-limiting; Metal-embossed date and catalog number for traceability and lasting identification; Time-delay for motor start-ups and transformer inrush currents without nuisance opening; Current-limiting for low peak let-thru current; Easy-to-read label for quick brand recognition and replacement; Feeders; Rejection-style design prevents replacement errors (when used with recommended fuse blocks); Service entrance equipment; Transformers; AC & DC rated; Time-delay; General-purpose equipment; Fiberglass body provides dimensional stability in harsh industrial settings; Branch circuits; UL listed to standard 248-12 File E2137; CSA certified to standard C22.2 no. 248.12; Motor circuits; High-grade silica filler ensures fast arc quenching and high current limitation; DC listed to UL standard 248 TRS only

$30.71 /EA
NOT CURRENTLY IN STOCK
  • « PREV
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • NEXT »