Browse Categories

Search in Category

Fuses

Search Filters

  • 5 in x
  • Mersen x

Filter Your Search

Shop by Category

Loading...

Fuses

Power Products/Fuses 
Viewing Page 1 of 17 (165 results)
600V 30A 5x13/16 TD FUSE

600V 30A 5x13/16 TD FUSE

Item #: TRS30R

Supplier Part #: TRS30R
Brand: Mersen

Tri-Onic TRS-R current-limiting time-delay fuses are engineered for overcurrent protection of motors, transformers, service entrance equipment, feeders and branch-circuits. The time-delay characteristics of the TRS-R safely handle harmless starting currents and inrush currents associated with today's motors and transformers.

Rejection-style design prevents replacement errors (when used with recommended fuse blocks); UL listed to standard 248-12 File E2137; Current-limiting for low peak let-thru current; Easy-to-read label for quick brand recognition and replacement; Mains; Motor circuits; Current-limiting; Optional solid state SmartSpot blown fuse indicator; AC & DC rated; Metal-embossed date and catalog number for traceability and lasting identification; Fiberglass body provides dimensional stability in harsh industrial settings; High-grade silica filler ensures fast arc quenching and high current limitation; Branch circuits; General-purpose equipment; Transformers; Time-delay for motor start-ups and transformer inrush currents without nuisance opening; Feeders; Service entrance equipment; CSA certified to standard C22.2 no. 248.12; Time-delay; DC listed to UL standard 248 TRS only

$23.68 /EA
IN STOCK

600V 5-6/10A RK1 TD FUSE USE

Item #: A6D5-6/10R

Supplier Part #: A6D5-6/10R
Brand: Mersen

Amp-Trap 2000® SmartSpot time-delay A6D-R fuses provide IEC Type 2 "no damage" protection to existing mains, feeders, and branch circuits serving motor and non-motor loads. A6D-R fuses will open fast enough under extreme fault conditions for maximum short circuit protection to prevent damage to motor starters, switches, and other circuit components, yet also provide the time-delay needed for motor in-rush currents. A6D-R fuses can be used to replace older 600V Class H, K or RK5 fuses already installed in the field.

Disconnects; Rejection-style design prevents replacement errors (when used with recommended fuse blocks); Fiberglass body provides dimensional stability in harsh industrial settings; Control panels; Recommended for Arc Flash energy reduction; 600VAC & 600VDC dual rated; Reduced inventory by taking the place of class RK5, K, and H fuses; CSA certified to standard C22.2 No. 248.12; DC listed to UL standard 248; Transformers; Safety switches; Branch circuit protection; Solid state SmartSpot visual blown fuse indicator; Time-delay for motor starting and transformer inrush currents without nuisance opening; Extremely current-limiting for low peak let-thru current; Metal-embossed date and catalog number for easier traceability and lasting identification; UL listed to standard 248-12 File E2137; Motors; High-visibility orange label gives instant brand recognition; Easy 2-to-1 selectivity for prevention of nuisance shut downs and “black outs”; All general-purpose circuits; 300kA interrupting rating – self-certified, UL witnessed tests

$44.64 /EA
IN STOCK

600V 6A RK1 TD FUSE

Item #: A6D6R

Supplier Part #: A6D6R
Brand: Mersen

Amp-Trap 2000® SmartSpot time-delay A6D-R fuses provide IEC Type 2 "no damage" protection to existing mains, feeders, and branch circuits serving motor and non-motor loads. A6D-R fuses will open fast enough under extreme fault conditions for maximum short circuit protection to prevent damage to motor starters, switches, and other circuit components, yet also provide the time-delay needed for motor in-rush currents. A6D-R fuses can be used to replace older 600V Class H, K or RK5 fuses already installed in the field.

Easy 2-to-1 selectivity for prevention of nuisance shut downs and “black outs”; Time-delay for motor starting and transformer inrush currents without nuisance opening; Extremely current-limiting for low peak let-thru current; Metal-embossed date and catalog number for easier traceability and lasting identification; 300kA interrupting rating – self-certified, UL witnessed tests; Safety switches; 600VAC & 600VDC dual rated; DC listed to UL standard 248; Transformers; Reduced inventory by taking the place of class RK5, K, and H fuses; Solid state SmartSpot visual blown fuse indicator; Branch circuit protection; UL listed to standard 248-12 File E2137; Fiberglass body provides dimensional stability in harsh industrial settings; High-visibility orange label gives instant brand recognition; Disconnects; Rejection-style design prevents replacement errors (when used with recommended fuse blocks); CSA certified to standard C22.2 No. 248.12; Motors; All general-purpose circuits; Control panels; Recommended for Arc Flash energy reduction

$39.48 /EA
IN STOCK
600V 17-1/2A RK1 TD FUSE

600V 17-1/2A RK1 TD FUSE

Item #: A6D17-1/2R

Supplier Part #: A6D17-1/2R
Brand: Mersen

Amp-Trap 2000® SmartSpot time-delay A6D-R fuses provide IEC Type 2 "no damage" protection to existing mains, feeders, and branch circuits serving motor and non-motor loads. A6D-R fuses will open fast enough under extreme fault conditions for maximum short circuit protection to prevent damage to motor starters, switches, and other circuit components, yet also provide the time-delay needed for motor in-rush currents. A6D-R fuses can be used to replace older 600V Class H, K or RK5 fuses already installed in the field.

Solid state SmartSpot visual blown fuse indicator; DC listed to UL standard 248; 300kA interrupting rating – self-certified, UL witnessed tests; 600VAC & 600VDC dual rated; Reduced inventory by taking the place of class RK5, K, and H fuses; Motors; Safety switches; Easy 2-to-1 selectivity for prevention of nuisance shut downs and “black outs”; UL listed to standard 248-12 File E2137; Recommended for Arc Flash energy reduction; High-visibility orange label gives instant brand recognition; Disconnects; All general-purpose circuits; Transformers; Branch circuit protection; CSA certified to standard C22.2 No. 248.12; Time-delay for motor starting and transformer inrush currents without nuisance opening; Rejection-style design prevents replacement errors (when used with recommended fuse blocks); Fiberglass body provides dimensional stability in harsh industrial settings; Extremely current-limiting for low peak let-thru current; Metal-embossed date and catalog number for easier traceability and lasting identification; Control panels

$34.79 /EA
IN STOCK
H TD FUSE 600V 15A CRS

H TD FUSE 600V 15A CRS

Item #: CRS15

Supplier Part #: CRS15
Brand: Mersen

Mersen CRN and CRS fuses are standard fuses, Type D, with 10kA short circuit rating. Type D fuses satisfy the Canadian Electrical Code requirement for low melting-point fuses

Type D fuses satisfy the Canadian Electrical Code requirement for low melting-point fuses; CSA Certified

$77.97 /EA
NOT CURRENTLY IN STOCK
H TD FUSE 600V 17-1/2A CRS

H TD FUSE 600V 17-1/2A CRS

Item #: CRS17-1/2

Supplier Part #: CRS17-1/2
Brand: Mersen

Mersen CRN and CRS fuses are standard fuses, Type D, with 10kA short circuit rating. Type D fuses satisfy the Canadian Electrical Code requirement for low melting-point fuses

CSA Certified; Type D fuses satisfy the Canadian Electrical Code requirement for low melting-point fuses

$77.97 /EA
NOT CURRENTLY IN STOCK
H TD FUSE 600V 20A CRS

H TD FUSE 600V 20A CRS

Item #: CRS20

Supplier Part #: CRS20
Brand: Mersen

Mersen CRN and CRS fuses are standard fuses, Type D, with 10kA short circuit rating. Type D fuses satisfy the Canadian Electrical Code requirement for low melting-point fuses

CSA Certified; Type D fuses satisfy the Canadian Electrical Code requirement for low melting-point fuses

$77.97 /EA
NOT CURRENTLY IN STOCK
H TD FUSE 600V 25A CRS

H TD FUSE 600V 25A CRS

Item #: CRS25

Supplier Part #: CRS25
Brand: Mersen

Mersen CRN and CRS fuses are standard fuses, Type D, with 10kA short circuit rating. Type D fuses satisfy the Canadian Electrical Code requirement for low melting-point fuses

CSA Certified; Type D fuses satisfy the Canadian Electrical Code requirement for low melting-point fuses

$77.97 /EA
NOT CURRENTLY IN STOCK
H TD FUSE 600V 30A CRS

H TD FUSE 600V 30A CRS

Item #: CRS30

Supplier Part #: CRS30
Brand: Mersen

Mersen CRN and CRS fuses are standard fuses, Type D, with 10kA short circuit rating. Type D fuses satisfy the Canadian Electrical Code requirement for low melting-point fuses

Type D fuses satisfy the Canadian Electrical Code requirement for low melting-point fuses; CSA Certified

$77.97 /EA
NOT CURRENTLY IN STOCK

600V 1-1/4A RK1 TD FUSE SE

Item #: A6D1-1/4R

Supplier Part #: A6D1-1/4R
Brand: Mersen

Amp-Trap 2000® SmartSpot time-delay A6D-R fuses provide IEC Type 2 "no damage" protection to existing mains, feeders, and branch circuits serving motor and non-motor loads. A6D-R fuses will open fast enough under extreme fault conditions for maximum short circuit protection to prevent damage to motor starters, switches, and other circuit components, yet also provide the time-delay needed for motor in-rush currents. A6D-R fuses can be used to replace older 600V Class H, K or RK5 fuses already installed in the field.

Fiberglass body provides dimensional stability in harsh industrial settings; All general-purpose circuits; Rejection-style design prevents replacement errors (when used with recommended fuse blocks); Metal-embossed date and catalog number for easier traceability and lasting identification; Control panels; High-visibility orange label gives instant brand recognition; DC listed to UL standard 248; 600VAC & 600VDC dual rated; Recommended for Arc Flash energy reduction; Time-delay for motor starting and transformer inrush currents without nuisance opening; Transformers; Disconnects; Extremely current-limiting for low peak let-thru current; Solid state SmartSpot visual blown fuse indicator; Easy 2-to-1 selectivity for prevention of nuisance shut downs and “black outs”; Safety switches; CSA certified to standard C22.2 No. 248.12; Branch circuit protection; Motors; Reduced inventory by taking the place of class RK5, K, and H fuses; 300kA interrupting rating – self-certified, UL witnessed tests; UL listed to standard 248-12 File E2137

$45.20 /EA
NOT CURRENTLY IN STOCK
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • NEXT »