NH 00 32A 690V GG

Item #: V228454

Supplier Part #: V228454
Brand: Mersen

The NH system is classified among plug-in fuse systems and is composed of , fuse-base (possibly including terminal covers and phase barriers) , fuse-link with blade contact , fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional. Type "gG" NH fuse-links are full range breaking capacity fuse-links and are used to protect cables and equipment. They can interrupt any current surge, from the lowest fusing current up to their breaking capacity, and so can be used alone as protection. They also protect electrical devices and industrial set-ups from the electrodynamic effects of very high short-circuit currents.

Lead free contact blades; VDE 0636 Part 201; IEC 60269-1 and -2; Non-isolated gripping lugs; Dimensions according to DIN 43 620 parts 1 to 4; Double indicator; 0% cadmium

$118.62 /EA
NOT CURRENTLY IN STOCK

NH 00 40A 690V GG

Item #: X228456

Supplier Part #: X228456
Brand: Mersen

The NH system is classified among plug-in fuse systems and is composed of , fuse-base (possibly including terminal covers and phase barriers) , fuse-link with blade contact , fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional. Type "gG" NH fuse-links are full range breaking capacity fuse-links and are used to protect cables and equipment. They can interrupt any current surge, from the lowest fusing current up to their breaking capacity, and so can be used alone as protection. They also protect electrical devices and industrial set-ups from the electrodynamic effects of very high short-circuit currents.

Non-isolated gripping lugs; Double indicator; Dimensions according to DIN 43 620 parts 1 to 4; IEC 60269-1 and -2; 0% cadmium; Lead free contact blades; VDE 0636 Part 201

$123.49 /EA
NOT CURRENTLY IN STOCK

BASE NH-00 EP BRID. F/TORN. 1P

Item #: T219805

Supplier Part #: T219805
Brand: Mersen

NH fuse-bases are available for delivery in single-pole and three-pole designs and can be closely mounted in parallel rows. Each three-pole base is upplied with two phase-partition walls. NH fuse-links plugon covers which clip onto the contact springs can also be supplied for these bases. Plastic fuse-bases sizes 00 to 3 have a single-part plastic base while size 4 has a metal baseplate with 2 ceramic bases. The stable silver-plated contact springs are made of electrolytic copper and formed from one piece. Separate springing is provided by highly resilient captive steel springs, making the contact invulnerable to high thermal stress. Size 4 NH fuse-bases are designed for size 4 fuse-links with 8 mm contact blades. A microswitch (250VAC/10A, terminal size 6.3x0.8mm) can be used with NH fuse-links with striker, it operates when fuse melts or where there is no fuse-link. Indirect touch protection fuse bases no microswitch possible. Rated impulse withstand voltage Uimp 6kV / 8kV (sizes 00 / 0-4)

Multipolar bases possible by direct linkage in 00 size and with separator accessory in sizes 0, 1, 2 and 3; Screw or rail mounting; Dimensions in accordance with DIN 43620; Polyamide insulating bases; Silver-plated contacts; IEC 60269 Compliance; DIN VDE 0636-2, 0636-21; High-pressure spring contacts

$84.00 /EA
NOT CURRENTLY IN STOCK
BASE NH 00-EP BRID. F/RAIL. 3P

BASE NH 00-EP BRID. F/RAIL. 3P

Item #: C212108

Supplier Part #: C212108
Brand: Mersen

NH fuse-bases are available for delivery in single-pole and three-pole designs and can be closely mounted in parallel rows. Each three-pole base is upplied with two phase-partition walls. NH fuse-links plugon covers which clip onto the contact springs can also be supplied for these bases. Plastic fuse-bases sizes 00 to 3 have a single-part plastic base while size 4 has a metal baseplate with 2 ceramic bases. The stable silver-plated contact springs are made of electrolytic copper and formed from one piece. Separate springing is provided by highly resilient captive steel springs, making the contact invulnerable to high thermal stress. Size 4 NH fuse-bases are designed for size 4 fuse-links with 8 mm contact blades. A microswitch (250VAC/10A, terminal size 6.3x0.8mm) can be used with NH fuse-links with striker, it operates when fuse melts or where there is no fuse-link. Indirect touch protection fuse bases no microswitch possible. Rated impulse withstand voltage Uimp 6kV / 8kV (sizes 00 / 0-4)

High-pressure spring contacts; IEC 60269 Compliance; Polyamide insulating bases; Dimensions in accordance with DIN 43620; Screw or rail mounting; Multipolar bases possible by direct linkage in 00 size and with separator accessory in sizes 0, 1, 2 and 3; Silver-plated contacts; DIN VDE 0636-2, 0636-21

$296.37 /EA
NOT CURRENTLY IN STOCK
6,9 URD 00 PV 0025

6,9 URD 00 PV 0025

Item #: C320139

Supplier Part #: C320139
Brand: Mersen

The 690/700V Protistor® fuse-links provide maximum flexibility in equipment design and ultimate protection for today's power conversion equipment. These NH style fuse-links are defined as per DIN 43620/00 for a worldwide acceptance into NH modular system fuse-holders, fuse switch disconnectors for direct installation. The Protistor® have been engineered to provide state-of-the-art protection for semiconductors diodes, thyristors, GTO's and IGBT devices. Fuses are assembled with pure silver, die-cut elements embedded in solidified sand, which helps control arcing characteristics for a lower I²t and high interrupting rating level. All contact surfaces are silver plated and all hardware is non-magnetic. Each fuse-link can be equipped with a low voltage trip-indicator which can operate a field mountable microswitch.

Superior cycling capability; Very low I²t for improved semiconductor protection; Ultra fast acting; Multiple body sizes; UL/CSA Recognized Component; aR Class according to VDE 636-23 and IEC 60269-4; Indication system with double indicator; Current limiting; IEC 60269-4 Compliance

$341.31 /EA
NOT CURRENTLY IN STOCK
NH 00 125A 400V GG

NH 00 125A 400V GG

Item #: E223702

Supplier Part #: E223702
Brand: Mersen

The NH system is classified among plug-in fuse systems and is composed of , fuse-base (possibly including terminal covers and phase barriers) , fuse-link with blade contact , fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional. Type "gG" NH fuse-links are full range breaking capacity fuse-links and are used to protect cables and equipment. They can interrupt any current surge, from the lowest fusing current up to their breaking capacity, and so can be used alone as protection. They also protect electrical devices and industrial set-ups from the electrodynamic effects of very high short-circuit currents. Rated Power Dissipation values of Mersen NH fuse-links 400VAC are below the maximum values required by standard IEC 60269.

0% cadmium; Non-isolated gripping lugs; Double indicator; Lead free contact blades; IEC 60269-1 and -2; VDE 0636 Part 201; Dimensions according to DIN 43 620 Parts 1 to 4

$130.06 /EA
NOT CURRENTLY IN STOCK

BASE NH 00-EP BRID. F/RAIL. 1P

Item #: F200795

Supplier Part #: F200795
Brand: Mersen

NH fuse-bases are available for delivery in single-pole and three-pole designs and can be closely mounted in parallel rows. Each three-pole base is upplied with two phase-partition walls. NH fuse-links plugon covers which clip onto the contact springs can also be supplied for these bases. Plastic fuse-bases sizes 00 to 3 have a single-part plastic base while size 4 has a metal baseplate with 2 ceramic bases. The stable silver-plated contact springs are made of electrolytic copper and formed from one piece. Separate springing is provided by highly resilient captive steel springs, making the contact invulnerable to high thermal stress. Size 4 NH fuse-bases are designed for size 4 fuse-links with 8 mm contact blades. A microswitch (250VAC/10A, terminal size 6.3x0.8mm) can be used with NH fuse-links with striker, it operates when fuse melts or where there is no fuse-link. Indirect touch protection fuse bases no microswitch possible. Rated impulse withstand voltage Uimp 6kV / 8kV (sizes 00 / 0-4)

Screw or rail mounting; Multipolar bases possible by direct linkage in 00 size and with separator accessory in sizes 0, 1, 2 and 3; Silver-plated contacts; Polyamide insulating bases; DIN VDE 0636-2, 0636-21; High-pressure spring contacts; Dimensions in accordance with DIN 43620; IEC 60269 Compliance

$88.77 /EA
NOT CURRENTLY IN STOCK

BASE NH 00-EP F/TORN. 1P

Item #: F215170

Supplier Part #: F215170
Brand: Mersen

NH fuse-bases are available for delivery in single-pole and three-pole designs and can be closely mounted in parallel rows. Each three-pole base is upplied with two phase-partition walls. NH fuse-links plugon covers which clip onto the contact springs can also be supplied for these bases. Plastic fuse-bases sizes 00 to 3 have a single-part plastic base while size 4 has a metal baseplate with 2 ceramic bases. The stable silver-plated contact springs are made of electrolytic copper and formed from one piece. Separate springing is provided by highly resilient captive steel springs, making the contact invulnerable to high thermal stress. Size 4 NH fuse-bases are designed for size 4 fuse-links with 8 mm contact blades. A microswitch (250VAC/10A, terminal size 6.3x0.8mm) can be used with NH fuse-links with striker, it operates when fuse melts or where there is no fuse-link. Indirect touch protection fuse bases no microswitch possible. Rated impulse withstand voltage Uimp 6kV / 8kV (sizes 00 / 0-4)

High-pressure spring contacts; IEC 60269 Compliance; Silver-plated contacts; Polyamide insulating bases; Screw or rail mounting; Multipolar bases possible by direct linkage in 00 size and with separator accessory in sizes 0, 1, 2 and 3; DIN VDE 0636-2, 0636-21; Dimensions in accordance with DIN 43620

$101.34 /EA
NOT CURRENTLY IN STOCK

BASE NH 00-EP F/RAIL 2P

Item #: F218758

Supplier Part #: F218758
Brand: Mersen

NH fuse-bases are available for delivery in single-pole and three-pole designs and can be closely mounted in parallel rows. Each three-pole base is upplied with two phase-partition walls. NH fuse-links plugon covers which clip onto the contact springs can also be supplied for these bases. Plastic fuse-bases sizes 00 to 3 have a single-part plastic base while size 4 has a metal baseplate with 2 ceramic bases. The stable silver-plated contact springs are made of electrolytic copper and formed from one piece. Separate springing is provided by highly resilient captive steel springs, making the contact invulnerable to high thermal stress. Size 4 NH fuse-bases are designed for size 4 fuse-links with 8 mm contact blades. A microswitch (250VAC/10A, terminal size 6.3x0.8mm) can be used with NH fuse-links with striker, it operates when fuse melts or where there is no fuse-link. Indirect touch protection fuse bases no microswitch possible. Rated impulse withstand voltage Uimp 6kV / 8kV (sizes 00 / 0-4)

High-pressure spring contacts; IEC 60269 Compliance; Silver-plated contacts; Multipolar bases possible by direct linkage in 00 size and with separator accessory in sizes 0, 1, 2 and 3; DIN VDE 0636-2, 0636-21; Polyamide insulating bases; Screw or rail mounting; Dimensions in accordance with DIN 43620

$163.29 /EA
NOT CURRENTLY IN STOCK

NH 00 160A 400V GG

Item #: F223703

Supplier Part #: F223703
Brand: Mersen

The NH system is classified among plug-in fuse systems and is composed of , fuse-base (possibly including terminal covers and phase barriers) , fuse-link with blade contact , fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional. Type "gG" NH fuse-links are full range breaking capacity fuse-links and are used to protect cables and equipment. They can interrupt any current surge, from the lowest fusing current up to their breaking capacity, and so can be used alone as protection. They also protect electrical devices and industrial set-ups from the electrodynamic effects of very high short-circuit currents. Rated Power Dissipation values of Mersen NH fuse-links 400VAC are below the maximum values required by standard IEC 60269.

Double indicator; IEC 60269-1 and -2; Dimensions according to DIN 43 620 Parts 1 to 4; Lead free contact blades; Non-isolated gripping lugs; VDE 0636 Part 201; 0% cadmium

$130.06 /EA
NOT CURRENTLY IN STOCK