Search in Category
Search Filters
-
5.5 in x
Filter Your Search
Shop by Category
Fuses
600V 40A 5 1/2x1 1/16 K5 FUSE
Residential and small commercial installations; UL Listed to Standard 248-9 File E2137; Self-certified for DC per UL248; Branch circuits; CSA Certified to Standard C22.2 No. 248.9 (The Canadian Electrical Code requires these fuses in ratings 15 through 60A to be of the low melting point design; use OTN 15-60.); Resistive heating; Low cost for high protection value; Feeders; Easy to read imprint label for quick recognition and replacement
600V 45A 5 1/2x1 1/16 K5 FUSE
Branch circuits; CSA Certified to Standard C22.2 No. 248.9 (The Canadian Electrical Code requires these fuses in ratings 15 through 60A to be of the low melting point design; use OTN 15-60.); UL Listed to Standard 248-9 File E2137; Feeders; Self-certified for DC per UL248; Resistive heating; Easy to read imprint label for quick recognition and replacement; Low cost for high protection value; Residential and small commercial installations
600V 50A 5 1/2x1 1/16 K5 FUSE
Feeders; Low cost for high protection value; Easy to read imprint label for quick recognition and replacement; Branch circuits; CSA Certified to Standard C22.2 No. 248.9 (The Canadian Electrical Code requires these fuses in ratings 15 through 60A to be of the low melting point design; use OTN 15-60.); Resistive heating; UL Listed to Standard 248-9 File E2137; Residential and small commercial installations; Self-certified for DC per UL248
600V 40A RK5 3-PACK
Easy-to-read label for quick brand recognition and replacement; Fiberglass body provides dimensional stability in harsh industrial settings; Metal-embossed date and catalog number for traceability and lasting identification; Time-delay; Mains; Transformers; Motor circuits; Branch circuits; Time-delay for motor start-ups and transformer inrush currents without nuisance opening; DC listed to UL standard 248 TRS only; Optional solid state SmartSpot blown fuse indicator; Service entrance equipment; UL listed to standard 248-12 File E2137; Feeders; Current-limiting; Current-limiting for low peak let-thru current; General-purpose equipment; Rejection-style design prevents replacement errors (when used with recommended fuse blocks); High-grade silica filler ensures fast arc quenching and high current limitation; AC & DC rated; CSA certified to standard C22.2 no. 248.12
74036-FUSE,TRIONIC
Rugged glass melamine body for superior reliability in harsh environments; Time-delay for motor start-ups and high inrush loads without nuisance opening; Mine circuits; Pump motors; Rail heaters; Trailing cables; MSHA approval no. 28-26-0; DC rated for mine duty and other long time-constant applications
600V 40A TD RK5 FUSE SMARTSPOT
Current-limiting for low peak let-thru current; Transformers; Mains; Time-delay for motor start-ups and transformer inrush currents without nuisance opening; Fiberglass body provides dimensional stability in harsh industrial settings; Feeders; General-purpose equipment; Time-delay; Rejection-style design prevents replacement errors (when used with recommended fuse blocks); DC listed to UL standard 248 TRS only; Optional solid state SmartSpot blown fuse indicator; Motor circuits; Metal-embossed date and catalog number for traceability and lasting identification; Easy-to-read label for quick brand recognition and replacement; UL listed to standard 248-12 File E2137; High-grade silica filler ensures fast arc quenching and high current limitation; Current-limiting; CSA certified to standard C22.2 no. 248.12; AC & DC rated; Service entrance equipment; Branch circuits
600V 45A 5 1/2x1 1/16 TD
Time-delay; Feeders; Rejection-style design prevents replacement errors (when used with recommended fuse blocks); Fiberglass body provides dimensional stability in harsh industrial settings; CSA certified to standard C22.2 no. 248.12; Optional solid state SmartSpot blown fuse indicator; Motor circuits; Transformers; High-grade silica filler ensures fast arc quenching and high current limitation; UL listed to standard 248-12 File E2137; DC listed to UL standard 248 TRS only; Mains; Easy-to-read label for quick brand recognition and replacement; Time-delay for motor start-ups and transformer inrush currents without nuisance opening; Service entrance equipment; AC & DC rated; Branch circuits; Current-limiting for low peak let-thru current; General-purpose equipment; Current-limiting; Metal-embossed date and catalog number for traceability and lasting identification
600V 45A RK5 3-PACK
General-purpose equipment; Optional solid state SmartSpot blown fuse indicator; UL listed to standard 248-12 File E2137; DC listed to UL standard 248 TRS only; Metal-embossed date and catalog number for traceability and lasting identification; High-grade silica filler ensures fast arc quenching and high current limitation; Branch circuits; Rejection-style design prevents replacement errors (when used with recommended fuse blocks); CSA certified to standard C22.2 no. 248.12; Fiberglass body provides dimensional stability in harsh industrial settings; Current-limiting for low peak let-thru current; Service entrance equipment; Time-delay; Easy-to-read label for quick brand recognition and replacement; Motor circuits; Transformers; AC & DC rated; Current-limiting; Time-delay for motor start-ups and transformer inrush currents without nuisance opening; Mains; Feeders
74037-FUSE,TRIONIC
Mine circuits; DC rated for mine duty and other long time-constant applications; Rugged glass melamine body for superior reliability in harsh environments; MSHA approval no. 28-26-0; Rail heaters; Pump motors; Time-delay for motor start-ups and high inrush loads without nuisance opening; Trailing cables
600V 45A TD RK5 FUSE SMARTSPOT
Transformers; Branch circuits; Service entrance equipment; UL listed to standard 248-12 File E2137; Time-delay; Fiberglass body provides dimensional stability in harsh industrial settings; Motor circuits; Easy-to-read label for quick brand recognition and replacement; Current-limiting; Metal-embossed date and catalog number for traceability and lasting identification; CSA certified to standard C22.2 no. 248.12; Mains; DC listed to UL standard 248 TRS only; High-grade silica filler ensures fast arc quenching and high current limitation; Feeders; Time-delay for motor start-ups and transformer inrush currents without nuisance opening; General-purpose equipment; AC & DC rated; Optional solid state SmartSpot blown fuse indicator; Rejection-style design prevents replacement errors (when used with recommended fuse blocks); Current-limiting for low peak let-thru current