Search in Category
Search Filters
-
5.5 in x
Filter Your Search
Shop by Category
Fuses
600V 35A 5 1/2x1 1/16 K5 FUSE
Self-certified for DC per UL248; Residential and small commercial installations; Branch circuits; Resistive heating; Feeders; UL Listed to Standard 248-9 File E2137; CSA Certified to Standard C22.2 No. 248.9 (The Canadian Electrical Code requires these fuses in ratings 15 through 60A to be of the low melting point design; use OTN 15-60.); Easy to read imprint label for quick recognition and replacement; Low cost for high protection value
H FUSE 600V 60A NRS
Non-time delay; Type “P” (15 – 60A); 250V and 600V applications
600V 40A 5 1/2x1 1/16 K5 FUSE
Residential and small commercial installations; UL Listed to Standard 248-9 File E2137; Self-certified for DC per UL248; Branch circuits; CSA Certified to Standard C22.2 No. 248.9 (The Canadian Electrical Code requires these fuses in ratings 15 through 60A to be of the low melting point design; use OTN 15-60.); Resistive heating; Low cost for high protection value; Feeders; Easy to read imprint label for quick recognition and replacement
600V 50A 5 1/2x1 1/16 K5 FUSE
Feeders; Low cost for high protection value; Easy to read imprint label for quick recognition and replacement; Branch circuits; CSA Certified to Standard C22.2 No. 248.9 (The Canadian Electrical Code requires these fuses in ratings 15 through 60A to be of the low melting point design; use OTN 15-60.); Resistive heating; UL Listed to Standard 248-9 File E2137; Residential and small commercial installations; Self-certified for DC per UL248
600V 60A 5 1/2x1 1/16 K5 FUSE
Self-certified for DC per UL248; Branch circuits; Easy to read imprint label for quick recognition and replacement; Feeders; Residential and small commercial installations; CSA Certified to Standard C22.2 No. 248.9 (The Canadian Electrical Code requires these fuses in ratings 15 through 60A to be of the low melting point design; use OTN 15-60.); Resistive heating; UL Listed to Standard 248-9 File E2137; Low cost for high protection value
H FUSE 600V 40A NRS
250V and 600V applications; Non-time delay; Type “P” (15 – 60A)
600V 45A 5 1/2x1 1/16 K5 FUSE
Branch circuits; CSA Certified to Standard C22.2 No. 248.9 (The Canadian Electrical Code requires these fuses in ratings 15 through 60A to be of the low melting point design; use OTN 15-60.); UL Listed to Standard 248-9 File E2137; Feeders; Self-certified for DC per UL248; Resistive heating; Easy to read imprint label for quick recognition and replacement; Low cost for high protection value; Residential and small commercial installations
600V 35A 5 1/2x1 1/16 TD
Optional solid state SmartSpot blown fuse indicator; Feeders; Time-delay for motor start-ups and transformer inrush currents without nuisance opening; Transformers; Branch circuits; Rejection-style design prevents replacement errors (when used with recommended fuse blocks); DC listed to UL standard 248 TRS only; Current-limiting; Service entrance equipment; Mains; Current-limiting for low peak let-thru current; General-purpose equipment; UL listed to standard 248-12 File E2137; Easy-to-read label for quick brand recognition and replacement; Motor circuits; High-grade silica filler ensures fast arc quenching and high current limitation; CSA certified to standard C22.2 no. 248.12; Time-delay; Fiberglass body provides dimensional stability in harsh industrial settings; Metal-embossed date and catalog number for traceability and lasting identification; AC & DC rated
600V 35A RK5 3-PACK
Transformers; Current-limiting for low peak let-thru current; AC & DC rated; DC listed to UL standard 248 TRS only; Time-delay for motor start-ups and transformer inrush currents without nuisance opening; Service entrance equipment; Mains; Branch circuits; CSA certified to standard C22.2 no. 248.12; Optional solid state SmartSpot blown fuse indicator; Metal-embossed date and catalog number for traceability and lasting identification; Easy-to-read label for quick brand recognition and replacement; Rejection-style design prevents replacement errors (when used with recommended fuse blocks); General-purpose equipment; Motor circuits; Feeders; Time-delay; Fiberglass body provides dimensional stability in harsh industrial settings; UL listed to standard 248-12 File E2137; High-grade silica filler ensures fast arc quenching and high current limitation; Current-limiting
74035-FUSE,TRIONIC
MSHA approval no. 28-26-0; Rail heaters; Trailing cables; DC rated for mine duty and other long time-constant applications; Mine circuits; Rugged glass melamine body for superior reliability in harsh environments; Time-delay for motor start-ups and high inrush loads without nuisance opening; Pump motors