D02-RECTIEINSATZ 63A 440V GR

D02-RECTIEINSATZ 63A 440V GR

Item #: Y207113

Supplier Part #: Y207113
Brand: Mersen

The D0 fuse-system is the most modern of the screw systems in the German DIN standard. This system comprises the sizes D01, D02 and D03. Those D0 ultra-fast acting “gR” ranges are dedicated to semi-conductor protection, in applications where fuse-links are accessible to non-trained persons and can also be changed by them. They are used for the protection of components such as diodes, thyristors or AC/DC motor drives. The “R” stands for the English word Rectifier. D0 fuse-links are available at the rated current range from 2A up to 100A.

IEC 60 269-4; Low power dissipation; Clear indication of operation condition due coloured indicator on top contact; DIN EN 60269-4 (VDE 0636-4); Top and bottom contacts made of nickel-plated/silver-plated copper alloy; Optimized size; DIN VDE 0636-3; Insulated body suitable for high mechanical and thermal impacts; Safe cut off short circuits and over currents due special design of fuse element; Resistant to aging

$37.24 /EA
NOT CURRENTLY IN STOCK
1250VDC NH3L GPV 350A

1250VDC NH3L GPV 350A

Item #: B1033391

Supplier Part #: B1033391
Brand: Mersen

Mersen HP12NH photovoltaic (PV) fuse series was engineered and designed specifically for the protection of photovoltaic systems. Helio-Protection® HP12NH fuse links are designed for the protection of cables in a PV group of chains when a short circuit occurs in a panel (main fuse category). This HelioProtection® main fuse range enlarges our PV fuse links offering on a size having a worldwide acceptance. They are of the gPV type and comply with both IEC 60269-6 and UL 2579 PV standards. They are also available with bolted type blades for direct mounting.

Durable construction for enhanced system longevity; Temperature cycle withstand capability; High efficiency with low power losses; Low fault current interrupting capability; IEC 60269-6; Global acceptance; RoHS compliance; UL 2579

$506.42 /EA
NOT CURRENTLY IN STOCK

DIV-RECTIEINSATZ 80A 500V GR

Item #: B201251

Supplier Part #: B201251
Brand: Mersen

The D fuse-system is the first generation of screw fuse-systems in the German DIN standard. It is still used in many installations. This D system comprises the sizes DII, DIII, DIV, DV. Those D ultra-fast acting “gR” ranges are dedicated to semi-conductor protection, in applications where fuse-links are accessible to non-trained persons and can also be changed by them. They are used for the protection of components such as diodes, thyristors or AC/DC motor drives. The “R” stands for the English word Rectifier. D fuse-links are available at the rated current range from 2A up to 200A.

Optimized size; DIN EN 60269-4 (VDE 0636-4); Top and bottom contacts made of nickel-plated/silver-plated copper alloy; IEC 60 269-4; Low power dissipation; Resistant to aging; DIN VDE 0636-3; Insulated body suitable for high mechanical and thermal impacts; Clear indication of operation condition due coloured indicator on top contact; Safe cut off short circuits and over currents due special design of fuse element

$85.91 /EA
NOT CURRENTLY IN STOCK
1250VDC NH3L gPV 400A

1250VDC NH3L gPV 400A

Item #: C1033392

Supplier Part #: C1033392
Brand: Mersen

Mersen HP12NH photovoltaic (PV) fuse series was engineered and designed specifically for the protection of photovoltaic systems. Helio-Protection® HP12NH fuse links are designed for the protection of cables in a PV group of chains when a short circuit occurs in a panel (main fuse category). This HelioProtection® main fuse range enlarges our PV fuse links offering on a size having a worldwide acceptance. They are of the gPV type and comply with both IEC 60269-6 and UL 2579 PV standards. They are also available with bolted type blades for direct mounting.

Global acceptance; RoHS compliance; Durable construction for enhanced system longevity; High efficiency with low power losses; Temperature cycle withstand capability; IEC 60269-6; UL 2579; Low fault current interrupting capability

$512.03 /EA
NOT CURRENTLY IN STOCK
NDZ-SICHEINSATZ 16A FLINK

NDZ-SICHEINSATZ 16A FLINK

Item #: D207049

Supplier Part #: D207049
Brand: Mersen

The D fuse-system is the first generation of screw fuse-system in the german DIN standard. It is still used in many installations. Applications are low voltage ditribution units, where non trained persons are allowed to change the fuse-links. The D flink fuse range comprises the sizes NDZ, DII, DIII. The range of applications for D flink fuse-links is the protection of equipments. The D flink fuse-links, not standardized by the IEC, are fast fuse-links whereas D gG fuse links are considered in comparison as slow fuse-links.

Resistant to aging; Top and bottom contacts made of nickel plated copper alloy; Insulated body suitable for high mechanical and thermal impacts; Optimized size; Free of lead, cadmium, mercury, chrome 6 (rohs conformity); Safe cut-off short circuits and over currents due to special design of fuse element; Low power dissipation; Clear indication of operation condition due to coloured indicator on top contact

$14.80 /EA
NOT CURRENTLY IN STOCK

DII-SICHEINSATZ 4A FLINK

Item #: D214064

Supplier Part #: D214064
Brand: Mersen

The D fuse-system is the first generation of screw fuse-system in the german DIN standard. It is still used in many installations. Applications are low voltage ditribution units, where non trained persons are allowed to change the fuse-links. The D flink fuse range comprises the sizes NDZ, DII, DIII. The range of applications for D flink fuse-links is the protection of equipments. The D flink fuse-links, not standardized by the IEC, are fast fuse-links whereas D gG fuse links are considered in comparison as slow fuse-links.

Clear indication of operation condition due to coloured indicator on top contact; Low power dissipation; Resistant to aging; Insulated body suitable for high mechanical and thermal impacts; Optimized size; Free of lead, cadmium, mercury, chrome 6 (rohs conformity); Top and bottom contacts made of nickel plated copper alloy; Safe cut-off short circuits and over currents due to special design of fuse element

$12.68 /EA
NOT CURRENTLY IN STOCK

DII-SICHEINSATZ 2A FLINK

Item #: E213559

Supplier Part #: E213559
Brand: Mersen

The D fuse-system is the first generation of screw fuse-system in the german DIN standard. It is still used in many installations. Applications are low voltage ditribution units, where non trained persons are allowed to change the fuse-links. The D flink fuse range comprises the sizes NDZ, DII, DIII. The range of applications for D flink fuse-links is the protection of equipments. The D flink fuse-links, not standardized by the IEC, are fast fuse-links whereas D gG fuse links are considered in comparison as slow fuse-links.

Optimized size; Free of lead, cadmium, mercury, chrome 6 (rohs conformity); Insulated body suitable for high mechanical and thermal impacts; Top and bottom contacts made of nickel plated copper alloy; Safe cut-off short circuits and over currents due to special design of fuse element; Clear indication of operation condition due to coloured indicator on top contact; Low power dissipation; Resistant to aging

$12.86 /EA
NOT CURRENTLY IN STOCK
DII-RECTIEINSATZ 4A 500V GR

DII-RECTIEINSATZ 4A 500V GR

Item #: K213058

Supplier Part #: K213058
Brand: Mersen

The D fuse-system is the first generation of screw fuse-systems in the German DIN standard. It is still used in many installations. This D system comprises the sizes DII, DIII, DIV, DV. Those D ultra-fast acting “gR” ranges are dedicated to semi-conductor protection, in applications where fuse-links are accessible to non-trained persons and can also be changed by them. They are used for the protection of components such as diodes, thyristors or AC/DC motor drives. The “R” stands for the English word Rectifier. D fuse-links are available at the rated current range from 2A up to 200A.

DIN EN 60269-4 (VDE 0636-4); Resistant to aging; Insulated body suitable for high mechanical and thermal impacts; DIN VDE 0636-3; Top and bottom contacts made of nickel-plated/silver-plated copper alloy; Optimized size; Clear indication of operation condition due coloured indicator on top contact; IEC 60 269-4; Safe cut off short circuits and over currents due special design of fuse element; Low power dissipation

$17.40 /EA
NOT CURRENTLY IN STOCK

DIII-SICHEINSATZ 50A GL-GG

Item #: K214576

Supplier Part #: K214576
Brand: Mersen

The D fuse-system is the first generation of screw fuse-system in the german DIN standard. It is still used in many installations. Applications are low voltage ditribution units, where non trained persons are allowed to change the fuse-links. The D fuse range comprises the sizes NDZ, DII, DIII, DIV, DV. The range of applications for D fuse-links is the protection of cables and power lines. They limit and cut-off unacceptable overcurrents and short circuit currents up to their nominal breaking capacity. D fuse-links "gG" also protect equipments and installations against dynamic effects of high short circuit currents.

Insulated body suitable for high mechanical and thermal impacts; Free of lead, cadmium, mercury, chrome 6 (rohs conformity); Optimized size; Low power dissipation; Safe cut-off short circuits and over currents due to special design of fuse element; DIN VDE 0636-301; Clear indication of operation condition due to coloured indicator on top contact; Resistant to aging; Top and bottom contacts made of nickel plated copper alloy

$21.41 /EA
NOT CURRENTLY IN STOCK

DIII-SEINSATZ 35A 500V GR

Item #: K217129

Supplier Part #: K217129
Brand: Mersen

The D fuse-system is the first generation of screw fuse-systems in the German DIN standard. It is still used in many installations. This D system comprises the sizes DII, DIII, DIV, DV. Those D ultra-fast acting “gR” ranges are dedicated to semi-conductor protection, in applications where fuse-links are accessible to non-trained persons and can also be changed by them. They are used for the protection of components such as diodes, thyristors or AC/DC motor drives. The “R” stands for the English word Rectifier. D fuse-links are available at the rated current range from 2A up to 200A.

Low power dissipation; Top and bottom contacts made of nickel-plated/silver-plated copper alloy; Optimized size; Resistant to aging; IEC 60 269-4; DIN EN 60269-4 (VDE 0636-4); DIN VDE 0636-3; Insulated body suitable for high mechanical and thermal impacts; Clear indication of operation condition due coloured indicator on top contact; Safe cut off short circuits and over currents due special design of fuse element

$75.76 /EA
NOT CURRENTLY IN STOCK