7.2KV 57X R-RATED SP IND BOLT-

7.2KV 57X R-RATED SP IND BOLT-

Item #: A072B3DCR0-57X

Supplier Part #: A072B3DCR0-57X
Brand: Mersen

Mersen R-Rated fuses are current-limiting, high interrupting rating fuses intended for the short circuit protection of medium voltage motors and motor controllers. R-Rated fuses are back-up fuses that have a minimum interrupting rating, and must be coordinated with overload relays in combination motor starters. The motor starter manufacturer generally specifies the R-Rated fuse size. These fuses are single, double, triple or quadruple barrels 3 inches diameter with end mounts designed for bolting directly to equipment bus or terminal pads

Bolt-in mounting for direct connection to bus or terminals; Metal embossed catalog number and manufacturing date for lasting identification; The Amp-Trap Bolt-in series are UL Recognized; Current-limiting for superior equipment protection; UL Recognized File E93367; Blown-fuse indicator to give positive identification of open fuse

$19,626.71 /EA
NOT CURRENTLY IN STOCK
7.2KV,442mm,3DIA,MV FUSE 16R

7.2KV,442mm,3DIA,MV FUSE 16R

Item #: A072D1DSR0-16R

Supplier Part #: A072D1DSR0-16R
Brand: Mersen

Amp-Trap® R-Rated DIN style fuses are current-limiting, high interrupting rating fuses, intended for the short circuit protection of medium voltage motors and motor controllers. This product range offers North American R-Rated performance in the IEC 282-1 DIN mounting configuration of 442mm. R-Rated fuses are applied as back up fuses that have a minimum interrupting rating, and must be coordinated with overload relays in combination motor starters. Amp-Trap R-Rated, DIN type fuses are offered in voltage ratings of 3.3kV, 5.3kV and 7.2kV in ratings from 2R to 19R. All fuses within this product group are UL component recognized. DEFINITIONS ,R-Rating R-Rated fuses are back-up fuses that operate as follows (Per ANSI C37.46-2000) An R-Rated fuse will melt in the range of 15 to 35 seconds at a value of current equal to 100 times the “R” rating ,Back-up Current-Limiting Fuses A back-up current-limiting fuse is a fuse that can interrupt any current between its rated minimum interrupting current and its maximum interrupting current. Back-up fuses are not designed or intended to open under overload conditions ,Continuous Ampere Rating at 40°C The continuous amp rating defines the thermal capability of the fuse per ANSI C37.46 and should not be the sole factor in fuse selection ,Spring-Reinforced Clip MR45 & Spring Ref.# L096472 ,Fuse-Holder SI 24/442 Ref # K209424 In compliance with IEC 282-1, DIN standard 43625 ,Note Ratings above 19R may be achieved by paralleling fuses. Please consult factory for details

Blown fuse indicator provides positive identification of open fuse. 4.5lb tripping force – 1.0”; UL recognized component File E93367; Current-limiting for superior equipment protection

$1,703.81 /EA
NOT CURRENTLY IN STOCK
7.2KV,442mm,3DIA,MV FUSE 19R

7.2KV,442mm,3DIA,MV FUSE 19R

Item #: A072D1DSR0-19R

Supplier Part #: A072D1DSR0-19R
Brand: Mersen

Amp-Trap® R-Rated DIN style fuses are current-limiting, high interrupting rating fuses, intended for the short circuit protection of medium voltage motors and motor controllers. This product range offers North American R-Rated performance in the IEC 282-1 DIN mounting configuration of 442mm. R-Rated fuses are applied as back up fuses that have a minimum interrupting rating, and must be coordinated with overload relays in combination motor starters. Amp-Trap R-Rated, DIN type fuses are offered in voltage ratings of 3.3kV, 5.3kV and 7.2kV in ratings from 2R to 19R. All fuses within this product group are UL component recognized. DEFINITIONS ,R-Rating R-Rated fuses are back-up fuses that operate as follows (Per ANSI C37.46-2000) An R-Rated fuse will melt in the range of 15 to 35 seconds at a value of current equal to 100 times the “R” rating ,Back-up Current-Limiting Fuses A back-up current-limiting fuse is a fuse that can interrupt any current between its rated minimum interrupting current and its maximum interrupting current. Back-up fuses are not designed or intended to open under overload conditions ,Continuous Ampere Rating at 40°C The continuous amp rating defines the thermal capability of the fuse per ANSI C37.46 and should not be the sole factor in fuse selection ,Spring-Reinforced Clip MR45 & Spring Ref.# L096472 ,Fuse-Holder SI 24/442 Ref # K209424 In compliance with IEC 282-1, DIN standard 43625 ,Note Ratings above 19R may be achieved by paralleling fuses. Please consult factory for details

Blown fuse indicator provides positive identification of open fuse. 4.5lb tripping force – 1.0”; Current-limiting for superior equipment protection; UL recognized component File E93367

$1,703.81 /EA
NOT CURRENTLY IN STOCK
7.2KV,442mm,3DIA,MV FUSE 2R

7.2KV,442mm,3DIA,MV FUSE 2R

Item #: A072D1DSR0-2R

Supplier Part #: A072D1DSR0-2R
Brand: Mersen

Amp-Trap® R-Rated DIN style fuses are current-limiting, high interrupting rating fuses, intended for the short circuit protection of medium voltage motors and motor controllers. This product range offers North American R-Rated performance in the IEC 282-1 DIN mounting configuration of 442mm. R-Rated fuses are applied as back up fuses that have a minimum interrupting rating, and must be coordinated with overload relays in combination motor starters. Amp-Trap R-Rated, DIN type fuses are offered in voltage ratings of 3.3kV, 5.3kV and 7.2kV in ratings from 2R to 19R. All fuses within this product group are UL component recognized. DEFINITIONS ,R-Rating R-Rated fuses are back-up fuses that operate as follows (Per ANSI C37.46-2000) An R-Rated fuse will melt in the range of 15 to 35 seconds at a value of current equal to 100 times the “R” rating ,Back-up Current-Limiting Fuses A back-up current-limiting fuse is a fuse that can interrupt any current between its rated minimum interrupting current and its maximum interrupting current. Back-up fuses are not designed or intended to open under overload conditions ,Continuous Ampere Rating at 40°C The continuous amp rating defines the thermal capability of the fuse per ANSI C37.46 and should not be the sole factor in fuse selection ,Spring-Reinforced Clip MR45 & Spring Ref.# L096472 ,Fuse-Holder SI 24/442 Ref # K209424 In compliance with IEC 282-1, DIN standard 43625 ,Note Ratings above 19R may be achieved by paralleling fuses. Please consult factory for details

Blown fuse indicator provides positive identification of open fuse. 4.5lb tripping force – 1.0”; UL recognized component File E93367; Current-limiting for superior equipment protection

$1,239.71 /EA
NOT CURRENTLY IN STOCK
7.2KV,442mm,3DIA,MV FUSE 3R

7.2KV,442mm,3DIA,MV FUSE 3R

Item #: A072D1DSR0-3R

Supplier Part #: A072D1DSR0-3R
Brand: Mersen

Amp-Trap® R-Rated DIN style fuses are current-limiting, high interrupting rating fuses, intended for the short circuit protection of medium voltage motors and motor controllers. This product range offers North American R-Rated performance in the IEC 282-1 DIN mounting configuration of 442mm. R-Rated fuses are applied as back up fuses that have a minimum interrupting rating, and must be coordinated with overload relays in combination motor starters. Amp-Trap R-Rated, DIN type fuses are offered in voltage ratings of 3.3kV, 5.3kV and 7.2kV in ratings from 2R to 19R. All fuses within this product group are UL component recognized. DEFINITIONS ,R-Rating R-Rated fuses are back-up fuses that operate as follows (Per ANSI C37.46-2000) An R-Rated fuse will melt in the range of 15 to 35 seconds at a value of current equal to 100 times the “R” rating ,Back-up Current-Limiting Fuses A back-up current-limiting fuse is a fuse that can interrupt any current between its rated minimum interrupting current and its maximum interrupting current. Back-up fuses are not designed or intended to open under overload conditions ,Continuous Ampere Rating at 40°C The continuous amp rating defines the thermal capability of the fuse per ANSI C37.46 and should not be the sole factor in fuse selection ,Spring-Reinforced Clip MR45 & Spring Ref.# L096472 ,Fuse-Holder SI 24/442 Ref # K209424 In compliance with IEC 282-1, DIN standard 43625 ,Note Ratings above 19R may be achieved by paralleling fuses. Please consult factory for details

Current-limiting for superior equipment protection; Blown fuse indicator provides positive identification of open fuse. 4.5lb tripping force – 1.0”; UL recognized component File E93367

$1,239.71 /EA
NOT CURRENTLY IN STOCK
7.2KV,442mm,3DIA,MV FUSE 4R

7.2KV,442mm,3DIA,MV FUSE 4R

Item #: A072D1DSR0-4R

Supplier Part #: A072D1DSR0-4R
Brand: Mersen

Amp-Trap® R-Rated DIN style fuses are current-limiting, high interrupting rating fuses, intended for the short circuit protection of medium voltage motors and motor controllers. This product range offers North American R-Rated performance in the IEC 282-1 DIN mounting configuration of 442mm. R-Rated fuses are applied as back up fuses that have a minimum interrupting rating, and must be coordinated with overload relays in combination motor starters. Amp-Trap R-Rated, DIN type fuses are offered in voltage ratings of 3.3kV, 5.3kV and 7.2kV in ratings from 2R to 19R. All fuses within this product group are UL component recognized. DEFINITIONS ,R-Rating R-Rated fuses are back-up fuses that operate as follows (Per ANSI C37.46-2000) An R-Rated fuse will melt in the range of 15 to 35 seconds at a value of current equal to 100 times the “R” rating ,Back-up Current-Limiting Fuses A back-up current-limiting fuse is a fuse that can interrupt any current between its rated minimum interrupting current and its maximum interrupting current. Back-up fuses are not designed or intended to open under overload conditions ,Continuous Ampere Rating at 40°C The continuous amp rating defines the thermal capability of the fuse per ANSI C37.46 and should not be the sole factor in fuse selection ,Spring-Reinforced Clip MR45 & Spring Ref.# L096472 ,Fuse-Holder SI 24/442 Ref # K209424 In compliance with IEC 282-1, DIN standard 43625 ,Note Ratings above 19R may be achieved by paralleling fuses. Please consult factory for details

Current-limiting for superior equipment protection; Blown fuse indicator provides positive identification of open fuse. 4.5lb tripping force – 1.0”; UL recognized component File E93367

$1,239.71 /EA
NOT CURRENTLY IN STOCK
7.2KV,442mm,3DIA,MV FUSE 5R

7.2KV,442mm,3DIA,MV FUSE 5R

Item #: A072D1DSR0-5R

Supplier Part #: A072D1DSR0-5R
Brand: Mersen

Amp-Trap® R-Rated DIN style fuses are current-limiting, high interrupting rating fuses, intended for the short circuit protection of medium voltage motors and motor controllers. This product range offers North American R-Rated performance in the IEC 282-1 DIN mounting configuration of 442mm. R-Rated fuses are applied as back up fuses that have a minimum interrupting rating, and must be coordinated with overload relays in combination motor starters. Amp-Trap R-Rated, DIN type fuses are offered in voltage ratings of 3.3kV, 5.3kV and 7.2kV in ratings from 2R to 19R. All fuses within this product group are UL component recognized. DEFINITIONS ,R-Rating R-Rated fuses are back-up fuses that operate as follows (Per ANSI C37.46-2000) An R-Rated fuse will melt in the range of 15 to 35 seconds at a value of current equal to 100 times the “R” rating ,Back-up Current-Limiting Fuses A back-up current-limiting fuse is a fuse that can interrupt any current between its rated minimum interrupting current and its maximum interrupting current. Back-up fuses are not designed or intended to open under overload conditions ,Continuous Ampere Rating at 40°C The continuous amp rating defines the thermal capability of the fuse per ANSI C37.46 and should not be the sole factor in fuse selection ,Spring-Reinforced Clip MR45 & Spring Ref.# L096472 ,Fuse-Holder SI 24/442 Ref # K209424 In compliance with IEC 282-1, DIN standard 43625 ,Note Ratings above 19R may be achieved by paralleling fuses. Please consult factory for details

Blown fuse indicator provides positive identification of open fuse. 4.5lb tripping force – 1.0”; Current-limiting for superior equipment protection; UL recognized component File E93367

$1,407.99 /EA
NOT CURRENTLY IN STOCK
7.2KV,442mm,3DIA,MV FUSE 6R

7.2KV,442mm,3DIA,MV FUSE 6R

Item #: A072D1DSR0-6R

Supplier Part #: A072D1DSR0-6R
Brand: Mersen

Amp-Trap® R-Rated DIN style fuses are current-limiting, high interrupting rating fuses, intended for the short circuit protection of medium voltage motors and motor controllers. This product range offers North American R-Rated performance in the IEC 282-1 DIN mounting configuration of 442mm. R-Rated fuses are applied as back up fuses that have a minimum interrupting rating, and must be coordinated with overload relays in combination motor starters. Amp-Trap R-Rated, DIN type fuses are offered in voltage ratings of 3.3kV, 5.3kV and 7.2kV in ratings from 2R to 19R. All fuses within this product group are UL component recognized. DEFINITIONS ,R-Rating R-Rated fuses are back-up fuses that operate as follows (Per ANSI C37.46-2000) An R-Rated fuse will melt in the range of 15 to 35 seconds at a value of current equal to 100 times the “R” rating ,Back-up Current-Limiting Fuses A back-up current-limiting fuse is a fuse that can interrupt any current between its rated minimum interrupting current and its maximum interrupting current. Back-up fuses are not designed or intended to open under overload conditions ,Continuous Ampere Rating at 40°C The continuous amp rating defines the thermal capability of the fuse per ANSI C37.46 and should not be the sole factor in fuse selection ,Spring-Reinforced Clip MR45 & Spring Ref.# L096472 ,Fuse-Holder SI 24/442 Ref # K209424 In compliance with IEC 282-1, DIN standard 43625 ,Note Ratings above 19R may be achieved by paralleling fuses. Please consult factory for details

UL recognized component File E93367; Current-limiting for superior equipment protection; Blown fuse indicator provides positive identification of open fuse. 4.5lb tripping force – 1.0”

$1,510.35 /EA
NOT CURRENTLY IN STOCK
7.2KV 2R R RATED FERRULE

7.2KV 2R R RATED FERRULE

Item #: A072F1D0R0-2R

Supplier Part #: A072F1D0R0-2R
Brand: Mersen

Mersen R-Rated fuses are current-limiting, high interrupting rating fuses intended for the short circuit protection of medium voltage motors and motor controllers. R-Rated fuses are back-up fuses that have a minimum interrupting rating, and must be coordinated with overload relays in combination motor starters. The motor starter manufacturer generally specifies the R-Rated fuse size. These fuses come with a 3 (size D) or 4 (size E) inch diameter barrels with ferrules and are mounted in spring reinforced clips

Blown-fuse indicator to give positive identification of open fuse; The Amp-Trap and 9F60 R-Rated fuses are UL Recognized; 9F60: UL File E191980; Ferrule mounting for standard clips and interchangeability with other brands of fuses; Amp-Trap: UL File E93367; Metal embossed catalog number and manufacturing date for lasting identification; On all other 3” barrels if a hookeye is required, use the operating eye 9F61AAW612; On the 4.8kV an optional hookeye mounted in the factory is available; Current-limiting for superior equipment protection

$1,296.43 /EA
NOT CURRENTLY IN STOCK
7.2KV 3R R RATED FERRULE

7.2KV 3R R RATED FERRULE

Item #: A072F1D0R0-3R

Supplier Part #: A072F1D0R0-3R
Brand: Mersen

Mersen R-Rated fuses are current-limiting, high interrupting rating fuses intended for the short circuit protection of medium voltage motors and motor controllers. R-Rated fuses are back-up fuses that have a minimum interrupting rating, and must be coordinated with overload relays in combination motor starters. The motor starter manufacturer generally specifies the R-Rated fuse size. These fuses come with a 3 (size D) or 4 (size E) inch diameter barrels with ferrules and are mounted in spring reinforced clips

Current-limiting for superior equipment protection; The Amp-Trap and 9F60 R-Rated fuses are UL Recognized; On the 4.8kV an optional hookeye mounted in the factory is available; 9F60: UL File E191980; Blown-fuse indicator to give positive identification of open fuse; On all other 3” barrels if a hookeye is required, use the operating eye 9F61AAW612; Amp-Trap: UL File E93367; Metal embossed catalog number and manufacturing date for lasting identification; Ferrule mounting for standard clips and interchangeability with other brands of fuses

$1,296.43 /EA