Fuses
250V 350A RK1 TD FUSE
Recommended for Arc Flash energy reduction; Fiberglass body provides dimensional stability in harsh industrial settings; Extremely current-limiting for low peak let-thru current; Control panels; Motors; Transformers; Solid state SmartSpot visual blown fuse indicator; Easy 2-to-1 selectivity for prevention of nuisance shut downs and “black outs”; 300kA interrupting rating – self-certified, UL witnessed tests; DC listed to UL standard 248; Reduced inventory by taking the place of class RK5, K, and H fuses; Time-delay for motor starting and transformer inrush currents without nuisance opening; All general-purpose circuits; Disconnects; UL listed to standard 248-12 File E2137; Branch circuit protection; 600VAC & 600VDC dual rated; CSA certified to standard C22.2 No. 248.12; Safety switches; Metal-embossed date and catalog number for easier traceability and lasting identification; Rejection-style design prevents replacement errors (when used with recommended fuse blocks); High-visibility orange label gives instant brand recognition
250V 400A RK1 TD FUSE
DC listed to UL standard 248; All general-purpose circuits; Rejection-style design prevents replacement errors (when used with recommended fuse blocks); Easy 2-to-1 selectivity for prevention of nuisance shut downs and “black outs”; Extremely current-limiting for low peak let-thru current; 600VAC & 600VDC dual rated; Motors; Disconnects; Fiberglass body provides dimensional stability in harsh industrial settings; Solid state SmartSpot visual blown fuse indicator; Transformers; CSA certified to standard C22.2 No. 248.12; Control panels; High-visibility orange label gives instant brand recognition; UL listed to standard 248-12 File E2137; Metal-embossed date and catalog number for easier traceability and lasting identification; 300kA interrupting rating – self-certified, UL witnessed tests; Recommended for Arc Flash energy reduction; Time-delay for motor starting and transformer inrush currents without nuisance opening; Reduced inventory by taking the place of class RK5, K, and H fuses; Branch circuit protection; Safety switches
250V 400A RK1 FUSE
Feeder circuits; Lighting circuits; Panelboards; Switchboards; High degree of current limitation for low peak let-thru current; CSA certified to standard C22.2 No. 248.12; Easy-to-read imprint label for quick recognition and replacement; Rejection style design prevents replacement by other fuse classes; Load centers; Bus duct; Fiberglass body provides dimensional stability in harsh industrial environments; Non-inductive loads; UL listed to standard 248-12 File E2137; Self-certified for DC per UL248
H TD FUSE 250V 225A CRN
Type D fuses satisfy the Canadian Electrical Code requirement for low melting-point fuses; CSA Certified
H TD FUSE 250V 250A CRN
CSA Certified; Type D fuses satisfy the Canadian Electrical Code requirement for low melting-point fuses
H TD FUSE 250V 300A CRN
CSA Certified; Type D fuses satisfy the Canadian Electrical Code requirement for low melting-point fuses
H TD FUSE 250V 350A CRN
CSA Certified; Type D fuses satisfy the Canadian Electrical Code requirement for low melting-point fuses
H TD FUSE 250V 400A CRN
CSA Certified; Type D fuses satisfy the Canadian Electrical Code requirement for low melting-point fuses
250V 225A 8 5/8x2 1/16 K5FUSE
Easy to read imprint label for quick recognition and replacement; Branch circuits; CSA Certified to Standard C22.2 No. 248.9 (The Canadian Electrical Code requires these fuses in ratings 15 through 60A to be of the low melting point design; use OTN 15-60.); Resistive heating; UL Listed to Standard 248-9 File E2137; Low cost for high protection value; Residential and small commercial installations; Self-certified for DC per UL248; Feeders
250V 250A 8 5/8x2 1/16 K5FUSE
Residential and small commercial installations; CSA Certified to Standard C22.2 No. 248.9 (The Canadian Electrical Code requires these fuses in ratings 15 through 60A to be of the low melting point design; use OTN 15-60.); Feeders; Resistive heating; UL Listed to Standard 248-9 File E2137; Low cost for high protection value; Self-certified for DC per UL248; Easy to read imprint label for quick recognition and replacement; Branch circuits