Fuses
250V 250A 8 5/8x2 1/10 TD
Time-delay; Optional solid state SmartSpot blown fuse indicator; Fiberglass body provides dimensional stability in harsh industrial settings; Branch circuits; General-purpose equipment; DC listed to UL standard 248 TRS only; Current-limiting; Current-limiting for low peak let-thru current; Time-delay for motor start-ups and transformer inrush currents without nuisance opening; High-grade silica filler ensures fast arc quenching and high current limitation; UL listed to standard 248-12 File E2137; Easy-to-read label for quick brand recognition and replacement; Motor circuits; Mains; Rejection-style design prevents replacement errors (when used with recommended fuse blocks); Metal-embossed date and catalog number for traceability and lasting identification; Service entrance equipment; Feeders; CSA certified to standard C22.2 no. 248.12; AC & DC rated; Transformers
250V 300A 8 5/8x2 1/10 TD
Optional solid state SmartSpot blown fuse indicator; Current-limiting; Current-limiting for low peak let-thru current; Easy-to-read label for quick brand recognition and replacement; General-purpose equipment; UL listed to standard 248-12 File E2137; High-grade silica filler ensures fast arc quenching and high current limitation; Time-delay for motor start-ups and transformer inrush currents without nuisance opening; Motor circuits; Time-delay; Transformers; Feeders; CSA certified to standard C22.2 no. 248.12; Fiberglass body provides dimensional stability in harsh industrial settings; Rejection-style design prevents replacement errors (when used with recommended fuse blocks); Service entrance equipment; AC & DC rated; DC listed to UL standard 248 TRS only; Metal-embossed date and catalog number for traceability and lasting identification; Mains; Branch circuits
250V 400A 8 5/8x2 1/10 TD
General-purpose equipment; Time-delay for motor start-ups and transformer inrush currents without nuisance opening; Transformers; Metal-embossed date and catalog number for traceability and lasting identification; Motor circuits; Branch circuits; Time-delay; AC & DC rated; Feeders; Current-limiting for low peak let-thru current; Fiberglass body provides dimensional stability in harsh industrial settings; CSA certified to standard C22.2 no. 248.12; High-grade silica filler ensures fast arc quenching and high current limitation; Rejection-style design prevents replacement errors (when used with recommended fuse blocks); Service entrance equipment; Optional solid state SmartSpot blown fuse indicator; Current-limiting; Mains; Easy-to-read label for quick brand recognition and replacement; UL listed to standard 248-12 File E2137; DC listed to UL standard 248 TRS only
250V 350A TD RK5 FUSE SMARTSPO
Branch circuits; Current-limiting for low peak let-thru current; Mains; Metal-embossed date and catalog number for traceability and lasting identification; Fiberglass body provides dimensional stability in harsh industrial settings; Motor circuits; Current-limiting; Rejection-style design prevents replacement errors (when used with recommended fuse blocks); Optional solid state SmartSpot blown fuse indicator; General-purpose equipment; UL listed to standard 248-12 File E2137; AC & DC rated; Transformers; DC listed to UL standard 248 TRS only; Service entrance equipment; High-grade silica filler ensures fast arc quenching and high current limitation; Time-delay for motor start-ups and transformer inrush currents without nuisance opening; Easy-to-read label for quick brand recognition and replacement; CSA certified to standard C22.2 no. 248.12; Time-delay; Feeders