250V 300A 8 5/8x2 1/16 K5FUSE
Low cost for high protection value; UL Listed to Standard 248-9 File E2137; Resistive heating; Self-certified for DC per UL248; CSA Certified to Standard C22.2 No. 248.9 (The Canadian Electrical Code requires these fuses in ratings 15 through 60A to be of the low melting point design; use OTN 15-60.); Easy to read imprint label for quick recognition and replacement; Residential and small commercial installations; Feeders; Branch circuits
250V 350A 8 5/8x2 1/16 K5FUSE
Residential and small commercial installations; Self-certified for DC per UL248; Low cost for high protection value; Resistive heating; Branch circuits; UL Listed to Standard 248-9 File E2137; CSA Certified to Standard C22.2 No. 248.9 (The Canadian Electrical Code requires these fuses in ratings 15 through 60A to be of the low melting point design; use OTN 15-60.); Easy to read imprint label for quick recognition and replacement; Feeders
250V 400A 8 5/8x2 1/16 K5FUSE
Easy to read imprint label for quick recognition and replacement; Branch circuits; Feeders; Self-certified for DC per UL248; UL Listed to Standard 248-9 File E2137; Low cost for high protection value; Resistive heating; Residential and small commercial installations; CSA Certified to Standard C22.2 No. 248.9 (The Canadian Electrical Code requires these fuses in ratings 15 through 60A to be of the low melting point design; use OTN 15-60.)
H TD FUSE 250V 225A CRN
Type D fuses satisfy the Canadian Electrical Code requirement for low melting-point fuses; CSA Certified
H TD FUSE 250V 250A CRN
CSA Certified; Type D fuses satisfy the Canadian Electrical Code requirement for low melting-point fuses
H TD FUSE 250V 300A CRN
CSA Certified; Type D fuses satisfy the Canadian Electrical Code requirement for low melting-point fuses
H TD FUSE 250V 350A CRN
CSA Certified; Type D fuses satisfy the Canadian Electrical Code requirement for low melting-point fuses
H TD FUSE 250V 400A CRN
CSA Certified; Type D fuses satisfy the Canadian Electrical Code requirement for low melting-point fuses
250V 225A 8 5/8x2 1/10 TD
Easy-to-read label for quick brand recognition and replacement; UL listed to standard 248-12 File E2137; Service entrance equipment; Motor circuits; Current-limiting for low peak let-thru current; Rejection-style design prevents replacement errors (when used with recommended fuse blocks); Time-delay for motor start-ups and transformer inrush currents without nuisance opening; Feeders; General-purpose equipment; Optional solid state SmartSpot blown fuse indicator; AC & DC rated; Time-delay; DC listed to UL standard 248 TRS only; Current-limiting; Mains; Transformers; High-grade silica filler ensures fast arc quenching and high current limitation; Fiberglass body provides dimensional stability in harsh industrial settings; Metal-embossed date and catalog number for traceability and lasting identification; CSA certified to standard C22.2 no. 248.12; Branch circuits
250V 225A TD RK5 FUSE SMARTSPO
Feeders; AC & DC rated; Optional solid state SmartSpot blown fuse indicator; Branch circuits; DC listed to UL standard 248 TRS only; Service entrance equipment; Current-limiting; Mains; Time-delay; Fiberglass body provides dimensional stability in harsh industrial settings; Easy-to-read label for quick brand recognition and replacement; Current-limiting for low peak let-thru current; CSA certified to standard C22.2 no. 248.12; Transformers; UL listed to standard 248-12 File E2137; Time-delay for motor start-ups and transformer inrush currents without nuisance opening; General-purpose equipment; Motor circuits; Rejection-style design prevents replacement errors (when used with recommended fuse blocks); High-grade silica filler ensures fast arc quenching and high current limitation; Metal-embossed date and catalog number for traceability and lasting identification