NH 000 35A 500V GG SGL

Item #: G201187

Supplier Part #: G201187
Brand: Mersen

The NH system is classified among plug-in fuse systems and is composed of , fuse-base (possibly including terminal covers and phase barriers) , fuse-link with blade contact , fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional. Type "gG" NH fuse-links are full range breaking capacity fuse-links and are used to protect cables and equipment. They can interrupt any current surge, from the lowest fusing current up to their breaking capacity, and so can be used alone as protection. They also protect electrical devices and industrial set-ups from the electrodynamic effects of very high short-circuit currents.

Isolated metal gripping lugs (SGL); Lead free contact blades; Double indicator; Dimensions according to DIN 43 620 Parts 1 to 4; VDE 0636 Part 201; 0% cadmium; IEC 60269-1 and -2

$119.44 /EA
NOT CURRENTLY IN STOCK
NH 000 32A 400V GG

NH 000 32A 400V GG

Item #: G223681

Supplier Part #: G223681
Brand: Mersen

The NH system is classified among plug-in fuse systems and is composed of , fuse-base (possibly including terminal covers and phase barriers) , fuse-link with blade contact , fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional. Type "gG" NH fuse-links are full range breaking capacity fuse-links and are used to protect cables and equipment. They can interrupt any current surge, from the lowest fusing current up to their breaking capacity, and so can be used alone as protection. They also protect electrical devices and industrial set-ups from the electrodynamic effects of very high short-circuit currents. Rated Power Dissipation values of Mersen NH fuse-links 400VAC are below the maximum values required by standard IEC 60269.

Lead free contact blades; Double indicator; Dimensions according to DIN 43 620 Parts 1 to 4; Non-isolated gripping lugs; 0% cadmium; IEC 60269-1 and -2; VDE 0636 Part 201

$130.06 /EA
NOT CURRENTLY IN STOCK

NH 000 6A 690V GG

Item #: G228442

Supplier Part #: G228442
Brand: Mersen

The NH system is classified among plug-in fuse systems and is composed of , fuse-base (possibly including terminal covers and phase barriers) , fuse-link with blade contact , fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional. Type "gG" NH fuse-links are full range breaking capacity fuse-links and are used to protect cables and equipment. They can interrupt any current surge, from the lowest fusing current up to their breaking capacity, and so can be used alone as protection. They also protect electrical devices and industrial set-ups from the electrodynamic effects of very high short-circuit currents.

Non-isolated gripping lugs; 0% cadmium; IEC 60269-1 and -2; Double indicator; VDE 0636 Part 201; Dimensions according to DIN 43 620 parts 1 to 4; Lead free contact blades

$123.49 /EA
NOT CURRENTLY IN STOCK

6,9 URD 000 PV 050

Item #: G320051

Supplier Part #: G320051
Brand: Mersen

The 690/700V Protistor® fuse-links provide maximum flexibility in equipment design and ultimate protection for today's power conversion equipment. These NH style fuse-links are defined as per DIN 43620/00 for a worldwide acceptance into NH modular system fuse-holders, fuse switch disconnectors for direct installation. The Protistor® have been engineered to provide state-of-the-art protection for semiconductors diodes, thyristors, GTO's and IGBT devices. Fuses are assembled with pure silver, die-cut elements embedded in solidified sand, which helps control arcing characteristics for a lower I²t and high interrupting rating level. All contact surfaces are silver plated and all hardware is non-magnetic. Each fuse-link can be equipped with a low voltage trip-indicator which can operate a field mountable microswitch.

Superior cycling capability; aR Class according to VDE 636-23 and IEC 60269-4; Very low I²t for improved semiconductor protection; Multiple body sizes; Ultra fast acting; Indication system with double indicator; UL/CSA Recognized Component; Current limiting; IEC 60269-4 Compliance

$317.66 /EA
NOT CURRENTLY IN STOCK

6,9 URB 000 BS 88/200

Item #: G330056

Supplier Part #: G330056
Brand: Mersen

The 690/700V Protistor® fuse-links provide maximum flexibility in equipment design and ultimate protection for small power conversion equipment. These ultra-fast acting aR fuses have been engineered to provide state-of-the-art protection for semiconductors diodes, thyristors and IGBT devices. They are assembled with die-cut elements embedded in solidified sand, which helps control arcing characteristics for a lower I²t and high interrupting rating level. All contact surfaces are silver plated and all hardware is non-magnetic. Each fuse-link can be equipped with a low voltage trip-indicator which can operate a field mountable microswitch.

IEC 60269-4 Compliance; Ultra fast acting; Superior cycling capability; Very low I²t for improved semiconductor protection; aR Class according to IEC 60269-4 and VDE 636-23; AC: UL Guide No. E76491; UL/CSA Recognized Component

$370.50 /EA
NOT CURRENTLY IN STOCK

5 URB 000 BS 88 400

Item #: G330194

Supplier Part #: G330194
Brand: Mersen

The 690/700V Protistor® fuse-links provide maximum flexibility in equipment design and ultimate protection for small power conversion equipment. These ultra-fast acting aR fuses have been engineered to provide state-of-the-art protection for semiconductors diodes, thyristors and IGBT devices. They are assembled with die-cut elements embedded in solidified sand, which helps control arcing characteristics for a lower I²t and high interrupting rating level. All contact surfaces are silver plated and all hardware is non-magnetic. Each fuse-link can be equipped with a low voltage trip-indicator which can operate a field mountable microswitch.

AC: UL Guide No. E76491; Ultra fast acting; Superior cycling capability; UL/CSA Recognized Component; aR Class according to IEC 60269-4 and VDE 636-23; Very low I²t for improved semiconductor protection; IEC 60269-4 Compliance

$304.10 /EA
NOT CURRENTLY IN STOCK

NH 000 35A 400V GG

Item #: H223682

Supplier Part #: H223682
Brand: Mersen

The NH system is classified among plug-in fuse systems and is composed of , fuse-base (possibly including terminal covers and phase barriers) , fuse-link with blade contact , fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional. Type "gG" NH fuse-links are full range breaking capacity fuse-links and are used to protect cables and equipment. They can interrupt any current surge, from the lowest fusing current up to their breaking capacity, and so can be used alone as protection. They also protect electrical devices and industrial set-ups from the electrodynamic effects of very high short-circuit currents. Rated Power Dissipation values of Mersen NH fuse-links 400VAC are below the maximum values required by standard IEC 60269.

Dimensions according to DIN 43 620 Parts 1 to 4; 0% cadmium; VDE 0636 Part 201; Lead free contact blades; IEC 60269-1 and -2; Non-isolated gripping lugs; Double indicator

$130.06 /EA
NOT CURRENTLY IN STOCK
6,9 URB 000 BS88 P 075

6,9 URB 000 BS88 P 075

Item #: H330126

Supplier Part #: H330126
Brand: Mersen

The 690/700V Protistor® fuse-links provide maximum flexibility in equipment design and ultimate protection for small power conversion equipment. These ultra-fast acting aR fuses have been engineered to provide state-of-the-art protection for semiconductors diodes, thyristors and IGBT devices. They are assembled with die-cut elements embedded in solidified sand, which helps control arcing characteristics for a lower I²t and high interrupting rating level. All contact surfaces are silver plated and all hardware is non-magnetic. Each fuse-link can be equipped with a low voltage trip-indicator which can operate a field mountable microswitch.

Superior cycling capability; Ultra fast acting; aR Class according to IEC 60269-4 and VDE 636-23; IEC 60269-4 Compliance; Very low I²t for improved semiconductor protection; AC: UL Guide No. E76491; UL/CSA Recognized Component

$563.23 /EA
NOT CURRENTLY IN STOCK
NH 000 2A 690V AM

NH 000 2A 690V AM

Item #: P227851

Supplier Part #: P227851
Brand: Mersen

The NH system is classified among plug-in fuse systems and is composed of , fuse-base (possibly including terminal covers and phase barriers) , fuse-link with blade contact , fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional. Type "aM" NH fuse-links are partial-range breaking capacity fuse-links, used to protect motor circuits as they are strongly current-limiting and have low power losses. They interrupt currents from 6.3 times In up to their maximum breaking capacity and are therefore suited for short-circuit protection only. They must be associated with other switchgear for protection against overloads. These fuse-links can have a rated current equal to the motor's nominal current.

IEC 60269-1 and -2; Dimensions according to DIN 43 620 parts 1 to 4; 0% cadmium; VDE 0636 Part 201; Double indicator; Non-isolated gripping lugs; Lead free contact blades

$128.52 /EA
NOT CURRENTLY IN STOCK

NH 000 35A 690V GG

Item #: P228449

Supplier Part #: P228449
Brand: Mersen

The NH system is classified among plug-in fuse systems and is composed of , fuse-base (possibly including terminal covers and phase barriers) , fuse-link with blade contact , fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional. Type "gG" NH fuse-links are full range breaking capacity fuse-links and are used to protect cables and equipment. They can interrupt any current surge, from the lowest fusing current up to their breaking capacity, and so can be used alone as protection. They also protect electrical devices and industrial set-ups from the electrodynamic effects of very high short-circuit currents.

Double indicator; VDE 0636 Part 201; Dimensions according to DIN 43 620 parts 1 to 4; Non-isolated gripping lugs; 0% cadmium; IEC 60269-1 and -2; Lead free contact blades

$123.49 /EA
NOT CURRENTLY IN STOCK