Search in Category
Search Filters
-
1.5 in x
Filter Your Search
Shop by Category
Fuses
500V 1A TD MIDGET FUSE
CSA Certified to Standard C22.2 No. 248.14; Time-delay (12 seconds at 200 percent rating) for circuits with high inrush current; Numerous ratings for a wide variety of applications up to 500VAC; Can be used with UltraSafe™ Fuse holders; UL listed to standard 248-14 File E33925; 1 1/2” x 13/32” (10 mm x 38 mm) dimensions; Supplemental protection of lighting, solenoid, motor and transformer circuits
CC TD FUSE 600V 4-1/2A ATQR
Highly current-limiting for low peak let-thru current; High-grade silica filler ensures fast arc quenching and high current limitation; UL listed to standard 248-4 File E2137; Fiberglass body provides dimensional stability in harsh industrial settings; Time-delay for control transformer inrush loads without nuisance opening; CSA certified to standard C22.2 No. 248.4; Solenoids; Metal-embossed date and catalog number for traceability and lasting identification; Inductive loads; High visibility orange label ensures instant brand recognition, and simplifies replacement; DC listed to UL standard 248; Control transformers; Lighting, heating & general-purpose loads; Rejection-style design prevents replacement errors (when used with recommended fuse blocks)
CC TD FUSE 600V 6A ATDR
UL listed to standard 248-4 File E2137; Small motors; Improved cycling ability for frequent motor starts/stops without nuisance fuse opening; Metal-embossed date and catalog number for traceability and lasting identification; CSA certified to standard C22.2 No. 248.4; Branch circuit protection; Rejection-style design prevents replacement errors (when used with recommended fuse blocks); Contactors; DC listed to UL standard 248; Highly current-limiting for low peak let-thru current; Fiberglass body provides dimensional stability in harsh industrial settings; Lighting, heating & general loads; High-visibility orange label ensures instant brand recognition, simplifies replacement; High-grade silica filler ensures fast arc quenching and optimum current-limitation; Time-delay for motor starting inrush currents without nuisance opening
500V 5A TD MIDGET FUSE
Can be used with UltraSafe™ Fuse holders; Numerous ratings for a wide variety of applications up to 500VAC; UL listed to standard 248-14 File E33925; CSA Certified to Standard C22.2 No. 248.14; Supplemental protection of lighting, solenoid, motor and transformer circuits; Time-delay (12 seconds at 200 percent rating) for circuits with high inrush current; 1 1/2” x 13/32” (10 mm x 38 mm) dimensions
TIME-DELAY FERRULE FUSE (12/32 in. x 1-1
BUSSMAN TYPR NQ-R FUSE 2A 500V
TIME DELAY FUSE, 3A, 600V
76159-FUSE 250V 1A 1-1/2X13/32
12 second time-delay at 200% rating; UL Listed to standard 248-14 (1/10 to 15A) File E33925; Numerous ratings for a wide variety of applications; 1 1/2” x 13/32” (10 mm x 38 mm) dimensions; For supplemental protection of circuits where time-delay and blown fuse indication are required, such as solenoid circuits or control circuits.; Can be used with UltraSafe™ fuse holders (1/10 – 10A); Pin indicator provides visual indication of open fuse or actuates switch for remote signaling; CSA Certified to Standard C22.2 No. 248.14 (1/10 to 15A)
70135- FUSE 250V 1-1/4A 1-1/2X
CSA Certified to Standard C22.2 No. 248.14 (1/10 to 15A); 12 second time-delay at 200% rating; Pin indicator provides visual indication of open fuse or actuates switch for remote signaling; 1 1/2” x 13/32” (10 mm x 38 mm) dimensions; Numerous ratings for a wide variety of applications; UL Listed to standard 248-14 (1/10 to 15A) File E33925; For supplemental protection of circuits where time-delay and blown fuse indication are required, such as solenoid circuits or control circuits.; Can be used with UltraSafe™ fuse holders (1/10 – 10A)
76160-FUSE 250V 1-1/8A 1-1/2X1
CSA Certified to Standard C22.2 No. 248.14 (1/10 to 15A); 1 1/2” x 13/32” (10 mm x 38 mm) dimensions; Pin indicator provides visual indication of open fuse or actuates switch for remote signaling; Numerous ratings for a wide variety of applications; 12 second time-delay at 200% rating; Can be used with UltraSafe™ fuse holders (1/10 – 10A); UL Listed to standard 248-14 (1/10 to 15A) File E33925; For supplemental protection of circuits where time-delay and blown fuse indication are required, such as solenoid circuits or control circuits.