Browse Categories

Search in Category

Fuses

Search Filters

  • 5500 V x

Filter Your Search

Shop by Category

Loading...

Fuses

Power Products/Fuses 
Viewing Page 7 of 19 (189 results)
5.5KV 80E E RATED CLIP-LOCK

5.5KV 80E E RATED CLIP-LOCK

Item #: A055C1D0R0-80E

Supplier Part #: A055C1D0R0-80E
Brand: Mersen

Mersen Amp-Trap fuses for the protection of transformers and distribution lines deliver overload and short circuit protection. These general purpose current-limiting fuses will melt at current that can be as low as 1.7 times the fuse current ratings up to its maximum interrupting rating. These fuses are designed to withstand the transformer magnetizing inrush current. They are single, double or triple barrels 3 inch diameter (size D) and mount in unique cam-locking clips for superior connections as well as easy installation and replacement.

Metal embossed catalog number and manufacturing date for lasting identification; Blown-fuse indicator to give positive identification of open fuse; UL listed for compatibility with UL listed equipment; Some UL Listed to standard File E143362; Clip-lock mounting for reliable high integrity connection into circuit; 2 lb tripped force – 0.50 Inch; Current-limiting for superior equipment protection; Non-venting for silent operation

$1,082.24 /EA
NOT CURRENTLY IN STOCK
5.5KV,442mm,3DIA,MV FUSE 13R

5.5KV,442mm,3DIA,MV FUSE 13R

Item #: A055D1DSR0-13R

Supplier Part #: A055D1DSR0-13R
Brand: Mersen

Amp-Trap® R-Rated DIN style fuses are current-limiting, high interrupting rating fuses, intended for the short circuit protection of medium voltage motors and motor controllers. This product range offers North American R-Rated performance in the IEC 282-1 DIN mounting configuration of 442mm. R-Rated fuses are applied as back up fuses that have a minimum interrupting rating, and must be coordinated with overload relays in combination motor starters. Amp-Trap R-Rated, DIN type fuses are offered in voltage ratings of 3.3kV, 5.3kV and 7.2kV in ratings from 2R to 19R. All fuses within this product group are UL component recognized. DEFINITIONS ,R-Rating R-Rated fuses are back-up fuses that operate as follows (Per ANSI C37.46-2000) An R-Rated fuse will melt in the range of 15 to 35 seconds at a value of current equal to 100 times the “R” rating ,Back-up Current-Limiting Fuses A back-up current-limiting fuse is a fuse that can interrupt any current between its rated minimum interrupting current and its maximum interrupting current. Back-up fuses are not designed or intended to open under overload conditions ,Continuous Ampere Rating at 40°C The continuous amp rating defines the thermal capability of the fuse per ANSI C37.46 and should not be the sole factor in fuse selection ,Spring-Reinforced Clip MR45 & Spring Ref.# L096472 ,Fuse-Holder SI 24/442 Ref # K209424 In compliance with IEC 282-1, DIN standard 43625 ,Note Ratings above 19R may be achieved by paralleling fuses. Please consult factory for details

Blown fuse indicator provides positive identification of open fuse. 4.5lb tripping force – 1.0”; UL recognized component File E93367; Current-limiting for superior equipment protection

$1,355.40 /EA
NOT CURRENTLY IN STOCK
5.5KV 40E E RATED FERRULE 2DIA

5.5KV 40E E RATED FERRULE 2DIA

Item #: A055F1C0R0-40E

Supplier Part #: A055F1C0R0-40E
Brand: Mersen

Mersen fuses for the protection of transformers and distribution lines deliver overload and short circuit protection. These current-limiting fuses will melt at current that can be as low as 1.7 times the fuse current ratings up to its maximum interrupting rating. These fuses are designed to withstand the transformer magnetizing inrush current. They have 2" (size C), 3" (size D) and 2x3" (size DD) inch diameter barrels with ferrules and are mounted in spring reinforced clips.

Amp-Trap CS-3 and 9F62 series are UL listed for compatibility with UL listed equipment; Outdoor usage for the 9F62 and 9F60 type EJO; Ferrule mounting for standard clips and interchangeability with other brands of fuses; Non-venting for silent operation; Some UL listed to standard File E143362; Metal embossed catalog number and manufacturing date for lasting identification; Current-limiting for superior equipment protection

$760.05 /EA
NOT CURRENTLY IN STOCK
5.5KV 50E E RATED FERRULE 2DIA

5.5KV 50E E RATED FERRULE 2DIA

Item #: A055F1C0R0-50E

Supplier Part #: A055F1C0R0-50E
Brand: Mersen

Mersen fuses for the protection of transformers and distribution lines deliver overload and short circuit protection. These current-limiting fuses will melt at current that can be as low as 1.7 times the fuse current ratings up to its maximum interrupting rating. These fuses are designed to withstand the transformer magnetizing inrush current. They have 2" (size C), 3" (size D) and 2x3" (size DD) inch diameter barrels with ferrules and are mounted in spring reinforced clips.

Non-venting for silent operation; Ferrule mounting for standard clips and interchangeability with other brands of fuses; Amp-Trap CS-3 and 9F62 series are UL listed for compatibility with UL listed equipment; Metal embossed catalog number and manufacturing date for lasting identification; Some UL listed to standard File E143362; Outdoor usage for the 9F62 and 9F60 type EJO; Current-limiting for superior equipment protection

$760.05 /EA
NOT CURRENTLY IN STOCK
5.5KV 100E E RATED FERRULE

5.5KV 100E E RATED FERRULE

Item #: A055F1D0R0-100E

Brand: Mersen

Mersen fuses for the protection of transformers and distribution lines deliver overload and short circuit protection. These current-limiting fuses will melt at current that can be as low as 1.7 times the fuse current ratings up to its maximum interrupting rating. These fuses are designed to withstand the transformer magnetizing inrush current. They have 2" (size C), 3" (size D) and 2x3" (size DD) inch diameter barrels with ferrules and are mounted in spring reinforced clips.

Some UL listed to standard File E143362; Current-limiting for superior equipment protection; Non-venting for silent operation; Metal embossed catalog number and manufacturing date for lasting identification; Ferrule mounting for standard clips and interchangeability with other brands of fuses; Outdoor usage for the 9F62 and 9F60 type EJO; Amp-Trap CS-3 and 9F62 series are UL listed for compatibility with UL listed equipment

$839.84 /EA
NOT CURRENTLY IN STOCK
5.5KV 10E E RATED FERRULE 3DIA

5.5KV 10E E RATED FERRULE 3DIA

Item #: A055F1D0R0-10E

Supplier Part #: A055F1D0R0-10E
Brand: Mersen

Mersen fuses for the protection of transformers and distribution lines deliver overload and short circuit protection. These current-limiting fuses will melt at current that can be as low as 1.7 times the fuse current ratings up to its maximum interrupting rating. These fuses are designed to withstand the transformer magnetizing inrush current. They have 2" (size C), 3" (size D) and 2x3" (size DD) inch diameter barrels with ferrules and are mounted in spring reinforced clips.

Amp-Trap CS-3 and 9F62 series are UL listed for compatibility with UL listed equipment; Outdoor usage for the 9F62 and 9F60 type EJO; Metal embossed catalog number and manufacturing date for lasting identification; Some UL listed to standard File E143362; Current-limiting for superior equipment protection; Non-venting for silent operation; Ferrule mounting for standard clips and interchangeability with other brands of fuses

$610.53 /EA
NOT CURRENTLY IN STOCK
5.5KV 20E E RATED FERRULE 3DIA

5.5KV 20E E RATED FERRULE 3DIA

Item #: A055F1D0R0-20E

Supplier Part #: A055F1D0R0-20E
Brand: Mersen

Mersen fuses for the protection of transformers and distribution lines deliver overload and short circuit protection. These current-limiting fuses will melt at current that can be as low as 1.7 times the fuse current ratings up to its maximum interrupting rating. These fuses are designed to withstand the transformer magnetizing inrush current. They have 2" (size C), 3" (size D) and 2x3" (size DD) inch diameter barrels with ferrules and are mounted in spring reinforced clips.

Current-limiting for superior equipment protection; Some UL listed to standard File E143362; Non-venting for silent operation; Outdoor usage for the 9F62 and 9F60 type EJO; Ferrule mounting for standard clips and interchangeability with other brands of fuses; Metal embossed catalog number and manufacturing date for lasting identification; Amp-Trap CS-3 and 9F62 series are UL listed for compatibility with UL listed equipment

$610.53 /EA
NOT CURRENTLY IN STOCK
5.5KV 25E E RATED FERRULE 3DIA

5.5KV 25E E RATED FERRULE 3DIA

Item #: A055F1D0R0-25E

Supplier Part #: A055F1D0R0-25E
Brand: Mersen

Mersen fuses for the protection of transformers and distribution lines deliver overload and short circuit protection. These current-limiting fuses will melt at current that can be as low as 1.7 times the fuse current ratings up to its maximum interrupting rating. These fuses are designed to withstand the transformer magnetizing inrush current. They have 2" (size C), 3" (size D) and 2x3" (size DD) inch diameter barrels with ferrules and are mounted in spring reinforced clips.

Current-limiting for superior equipment protection; Amp-Trap CS-3 and 9F62 series are UL listed for compatibility with UL listed equipment; Some UL listed to standard File E143362; Metal embossed catalog number and manufacturing date for lasting identification; Ferrule mounting for standard clips and interchangeability with other brands of fuses; Outdoor usage for the 9F62 and 9F60 type EJO; Non-venting for silent operation

$610.53 /EA
NOT CURRENTLY IN STOCK
5.5KV, 40AMPS, TYPE 15, MV CAP

5.5KV, 40AMPS, TYPE 15, MV CAP

Item #: A550C40-15

Supplier Part #: A550C40-15
Brand: Mersen

Mersen capacitor fuses are designed to ANSI C37-41. They are currentlimiting operating without noise or discharge and are designed to be used indoors in a general purpose enclosure or outdoors in a weatherproof enclosure. These are non-disconnecting fuses requiring the use of a disconnect switch. These capacitor fuses provide both short circuit and overload protection and are intended to protect against capacitor case rupture or dielectric failure within the capacitor. The various mounting configurations offer manufacturers a wide range of cost/space saving solutions and a large choice of equivalent products

Blown-fuse indication; ANSI C37-41; Direct mount; Non-venting for silent operation; Clip style mount; Bus mount; Current limitation; High interrupting capacity

$315.89 /EA
NOT CURRENTLY IN STOCK
5.5KV, 40 AMPS, TYPE 70, MV CA

5.5KV, 40 AMPS, TYPE 70, MV CA

Item #: A550C40-70

Supplier Part #: A550C40-70
Brand: Mersen

Mersen capacitor fuses are designed to ANSI C37-41. They are currentlimiting operating without noise or discharge and are designed to be used indoors in a general purpose enclosure or outdoors in a weatherproof enclosure. These are non-disconnecting fuses requiring the use of a disconnect switch. These capacitor fuses provide both short circuit and overload protection and are intended to protect against capacitor case rupture or dielectric failure within the capacitor. The various mounting configurations offer manufacturers a wide range of cost/space saving solutions and a large choice of equivalent products

Non-venting for silent operation; High interrupting capacity; Direct mount; Bus mount; Clip style mount; Current limitation; ANSI C37-41; Blown-fuse indication

$305.92 /EA
NOT CURRENTLY IN STOCK
  • « PREV
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • NEXT »