4.3KV, 90AMPS, TYPE 15, MV CAP

4.3KV, 90AMPS, TYPE 15, MV CAP

Item #: A430C90-15

Supplier Part #: A430C90-15
Brand: Mersen

Mersen capacitor fuses are designed to ANSI C37-41. They are currentlimiting operating without noise or discharge and are designed to be used indoors in a general purpose enclosure or outdoors in a weatherproof enclosure. These are non-disconnecting fuses requiring the use of a disconnect switch. These capacitor fuses provide both short circuit and overload protection and are intended to protect against capacitor case rupture or dielectric failure within the capacitor. The various mounting configurations offer manufacturers a wide range of cost/space saving solutions and a large choice of equivalent products

Blown-fuse indication; Non-venting for silent operation; Current limitation; ANSI C37-41; Direct mount; Clip style mount; High interrupting capacity; Bus mount

$385.71 /EA
NOT CURRENTLY IN STOCK
4.3KV 90A TYPE 70, MV Cap

4.3KV 90A TYPE 70, MV Cap

Item #: A430C90-70

Supplier Part #: A430C90-70
Brand: Mersen

Mersen capacitor fuses are designed to ANSI C37-41. They are currentlimiting operating without noise or discharge and are designed to be used indoors in a general purpose enclosure or outdoors in a weatherproof enclosure. These are non-disconnecting fuses requiring the use of a disconnect switch. These capacitor fuses provide both short circuit and overload protection and are intended to protect against capacitor case rupture or dielectric failure within the capacitor. The various mounting configurations offer manufacturers a wide range of cost/space saving solutions and a large choice of equivalent products

Bus mount; Blown-fuse indication; Clip style mount; Current limitation; Non-venting for silent operation; High interrupting capacity; Direct mount; ANSI C37-41

$372.40 /EA
NOT CURRENTLY IN STOCK
4.3KV, 90 AMPS, TYPE 75, MV CA

4.3KV, 90 AMPS, TYPE 75, MV CA

Item #: A430C90-75

Supplier Part #: A430C90-75
Brand: Mersen

Mersen capacitor fuses are designed to ANSI C37-41. They are currentlimiting operating without noise or discharge and are designed to be used indoors in a general purpose enclosure or outdoors in a weatherproof enclosure. These are non-disconnecting fuses requiring the use of a disconnect switch. These capacitor fuses provide both short circuit and overload protection and are intended to protect against capacitor case rupture or dielectric failure within the capacitor. The various mounting configurations offer manufacturers a wide range of cost/space saving solutions and a large choice of equivalent products

Current limitation; Bus mount; High interrupting capacity; ANSI C37-41; Blown-fuse indication; Direct mount; Clip style mount; Non-venting for silent operation

$412.22 /EA
NOT CURRENTLY IN STOCK
L TD FUSE 600V 200A A4BQ

L TD FUSE 600V 200A A4BQ

Item #: A4BQ200

Supplier Part #: A4BQ200
Brand: Mersen

Amp-Trap 2000 A4BQ fuses are 20 percent more current limiting than any other Class L fuse on the market. When correctly coordinated, they bring a superior level of protection to service entrance equipment. Downstream circuit components have maximum protection against short circuit let-thru current. A4BQ's built-in 4-second time-delay characteristic (at 500percent of rated current) accommodates harmless inrush currents with no nuisance opening.

Optional mechanical TA indicator (100-6000A). Please contact factory for special trigger actuator; UL listed; High-visibility orange label gives instant brand recognition; Fastest operation under short circuit conditions: Let-thru currents are typically 20 percent lower, with a corresponding let-thru energy (clearing I2t) up to 40% lower than the next fastest Class L fuse; Feeders; DC listed to UL standard 248 (100-2000A); Lighting, heating & general loads; Easy 2-to-1 selectivity for prevention of nuisance shutdowns and “blackouts”; Time-delay for high inrush loads such as motors and transformers, without nuisance opening; 300kA interrupting rating – self-certified, UL witnessed tests; Rejection-style design prevents replacement errors; Reduced inventory because A4BQ can replace all older types of Class L fuses now in-service; High-grade silica filler ensures fast arc quenching; Mains; Large motors; CSA certified to standard C22.2 No. 248.10 (601-6000A); Pure silver links ensure lowest let-thru current and longer fuse life; Most current-limiting for lowest peak let-thru current; even at fault currents up to 300kA; Recommended for Arc Flash energy reduction; Fiberglass body provides dimensional stability in harsh industrial settings; UL listed to standard 248-10 File E2137; Metal-embossed date and catalog number for traceability and lasting identification; Circuit breaker back-up

$1,332.01 /EA
NOT CURRENTLY IN STOCK
600V 200A CLASS L TD FUSEW/TA

600V 200A CLASS L TD FUSEW/TA

Item #: A4BQ200-TA

Supplier Part #: A4BQ200-TA
Brand: Mersen

Amp-Trap 2000 A4BQ fuses are 20 percent more current limiting than any other Class L fuse on the market. When correctly coordinated, they bring a superior level of protection to service entrance equipment. Downstream circuit components have maximum protection against short circuit let-thru current. A4BQ's built-in 4-second time-delay characteristic (at 500percent of rated current) accommodates harmless inrush currents with no nuisance opening.

UL listed; High-visibility orange label gives instant brand recognition; UL listed to standard 248-10 File E2137; Feeders; DC listed to UL standard 248 (100-2000A); Most current-limiting for lowest peak let-thru current; even at fault currents up to 300kA; Large motors; CSA certified to standard C22.2 No. 248.10 (601-6000A); 300kA interrupting rating – self-certified, UL witnessed tests; Recommended for Arc Flash energy reduction; Time-delay for high inrush loads such as motors and transformers, without nuisance opening; Circuit breaker back-up; Reduced inventory because A4BQ can replace all older types of Class L fuses now in-service; High-grade silica filler ensures fast arc quenching; Mains; Rejection-style design prevents replacement errors; Metal-embossed date and catalog number for traceability and lasting identification; Pure silver links ensure lowest let-thru current and longer fuse life; Lighting, heating & general loads; Easy 2-to-1 selectivity for prevention of nuisance shutdowns and “blackouts”; Fiberglass body provides dimensional stability in harsh industrial settings; Optional mechanical TA indicator (100-6000A). Please contact factory for special trigger actuator; Fastest operation under short circuit conditions: Let-thru currents are typically 20 percent lower, with a corresponding let-thru energy (clearing I2t) up to 40% lower than the next fastest Class L fuse

$1,377.34 /EA
NOT CURRENTLY IN STOCK
600V 250A CLASS L TD FUSEW/TA

600V 250A CLASS L TD FUSEW/TA

Item #: A4BQ250-TA

Supplier Part #: A4BQ250-TA
Brand: Mersen

Amp-Trap 2000 A4BQ fuses are 20 percent more current limiting than any other Class L fuse on the market. When correctly coordinated, they bring a superior level of protection to service entrance equipment. Downstream circuit components have maximum protection against short circuit let-thru current. A4BQ's built-in 4-second time-delay characteristic (at 500percent of rated current) accommodates harmless inrush currents with no nuisance opening.

DC listed to UL standard 248 (100-2000A); Most current-limiting for lowest peak let-thru current; even at fault currents up to 300kA; UL listed; 300kA interrupting rating – self-certified, UL witnessed tests; Recommended for Arc Flash energy reduction; High-visibility orange label gives instant brand recognition; Fiberglass body provides dimensional stability in harsh industrial settings; Fastest operation under short circuit conditions: Let-thru currents are typically 20 percent lower, with a corresponding let-thru energy (clearing I2t) up to 40% lower than the next fastest Class L fuse; Metal-embossed date and catalog number for traceability and lasting identification; High-grade silica filler ensures fast arc quenching; CSA certified to standard C22.2 No. 248.10 (601-6000A); Rejection-style design prevents replacement errors; Time-delay for high inrush loads such as motors and transformers, without nuisance opening; Feeders; Lighting, heating & general loads; Reduced inventory because A4BQ can replace all older types of Class L fuses now in-service; UL listed to standard 248-10 File E2137; Pure silver links ensure lowest let-thru current and longer fuse life; Mains; Circuit breaker back-up; Easy 2-to-1 selectivity for prevention of nuisance shutdowns and “blackouts”; Large motors; Optional mechanical TA indicator (100-6000A). Please contact factory for special trigger actuator

$1,377.34 /EA
NOT CURRENTLY IN STOCK
600V 500A CLASS L TD FUSEW/TA

600V 500A CLASS L TD FUSEW/TA

Item #: A4BQ500-TA

Supplier Part #: A4BQ500-TA
Brand: Mersen

Amp-Trap 2000 A4BQ fuses are 20 percent more current limiting than any other Class L fuse on the market. When correctly coordinated, they bring a superior level of protection to service entrance equipment. Downstream circuit components have maximum protection against short circuit let-thru current. A4BQ's built-in 4-second time-delay characteristic (at 500percent of rated current) accommodates harmless inrush currents with no nuisance opening.

Pure silver links ensure lowest let-thru current and longer fuse life; Optional mechanical TA indicator (100-6000A). Please contact factory for special trigger actuator; UL listed to standard 248-10 File E2137; Lighting, heating & general loads; Reduced inventory because A4BQ can replace all older types of Class L fuses now in-service; Large motors; UL listed; Mains; High-grade silica filler ensures fast arc quenching; Recommended for Arc Flash energy reduction; Circuit breaker back-up; Feeders; CSA certified to standard C22.2 No. 248.10 (601-6000A); DC listed to UL standard 248 (100-2000A); Metal-embossed date and catalog number for traceability and lasting identification; High-visibility orange label gives instant brand recognition; Easy 2-to-1 selectivity for prevention of nuisance shutdowns and “blackouts”; Fastest operation under short circuit conditions: Let-thru currents are typically 20 percent lower, with a corresponding let-thru energy (clearing I2t) up to 40% lower than the next fastest Class L fuse; Fiberglass body provides dimensional stability in harsh industrial settings; Rejection-style design prevents replacement errors; 300kA interrupting rating – self-certified, UL witnessed tests; Time-delay for high inrush loads such as motors and transformers, without nuisance opening; Most current-limiting for lowest peak let-thru current; even at fault currents up to 300kA

$1,377.34 /EA
NOT CURRENTLY IN STOCK
L TD FUSE 600V 600A A4BQ

L TD FUSE 600V 600A A4BQ

Item #: A4BQ600

Supplier Part #: A4BQ600
Brand: Mersen

Amp-Trap 2000 A4BQ fuses are 20 percent more current limiting than any other Class L fuse on the market. When correctly coordinated, they bring a superior level of protection to service entrance equipment. Downstream circuit components have maximum protection against short circuit let-thru current. A4BQ's built-in 4-second time-delay characteristic (at 500percent of rated current) accommodates harmless inrush currents with no nuisance opening.

High-visibility orange label gives instant brand recognition; UL listed to standard 248-10 File E2137; 300kA interrupting rating – self-certified, UL witnessed tests; Large motors; Mains; Feeders; Rejection-style design prevents replacement errors; Fastest operation under short circuit conditions: Let-thru currents are typically 20 percent lower, with a corresponding let-thru energy (clearing I2t) up to 40% lower than the next fastest Class L fuse; Reduced inventory because A4BQ can replace all older types of Class L fuses now in-service; Recommended for Arc Flash energy reduction; Most current-limiting for lowest peak let-thru current; even at fault currents up to 300kA; High-grade silica filler ensures fast arc quenching; CSA certified to standard C22.2 No. 248.10 (601-6000A); Fiberglass body provides dimensional stability in harsh industrial settings; Lighting, heating & general loads; Circuit breaker back-up; Pure silver links ensure lowest let-thru current and longer fuse life; Easy 2-to-1 selectivity for prevention of nuisance shutdowns and “blackouts”; UL listed; DC listed to UL standard 248 (100-2000A); Optional mechanical TA indicator (100-6000A). Please contact factory for special trigger actuator; Time-delay for high inrush loads such as motors and transformers, without nuisance opening; Metal-embossed date and catalog number for traceability and lasting identification

$1,332.01 /EA
NOT CURRENTLY IN STOCK
600V 600A CLASS L TD FUSEW/TA

600V 600A CLASS L TD FUSEW/TA

Item #: A4BQ600-TA

Supplier Part #: A4BQ600-TA
Brand: Mersen

Amp-Trap 2000 A4BQ fuses are 20 percent more current limiting than any other Class L fuse on the market. When correctly coordinated, they bring a superior level of protection to service entrance equipment. Downstream circuit components have maximum protection against short circuit let-thru current. A4BQ's built-in 4-second time-delay characteristic (at 500percent of rated current) accommodates harmless inrush currents with no nuisance opening.

High-grade silica filler ensures fast arc quenching; Fiberglass body provides dimensional stability in harsh industrial settings; Reduced inventory because A4BQ can replace all older types of Class L fuses now in-service; Time-delay for high inrush loads such as motors and transformers, without nuisance opening; Mains; Large motors; Feeders; Optional mechanical TA indicator (100-6000A). Please contact factory for special trigger actuator; UL listed to standard 248-10 File E2137; Fastest operation under short circuit conditions: Let-thru currents are typically 20 percent lower, with a corresponding let-thru energy (clearing I2t) up to 40% lower than the next fastest Class L fuse; Recommended for Arc Flash energy reduction; Most current-limiting for lowest peak let-thru current; even at fault currents up to 300kA; Rejection-style design prevents replacement errors; Lighting, heating & general loads; Easy 2-to-1 selectivity for prevention of nuisance shutdowns and “blackouts”; Circuit breaker back-up; Metal-embossed date and catalog number for traceability and lasting identification; High-visibility orange label gives instant brand recognition; CSA certified to standard C22.2 No. 248.10 (601-6000A); UL listed; DC listed to UL standard 248 (100-2000A); 300kA interrupting rating – self-certified, UL witnessed tests; Pure silver links ensure lowest let-thru current and longer fuse life

$1,377.34 /EA
NOT CURRENTLY IN STOCK
SC FUSE 1500V 125A X BLADE TA

SC FUSE 1500V 125A X BLADE TA

Item #: A150X125-4TA

Supplier Part #: A150X125-4TA
Brand: Mersen

A150X Amp-Trap® Form 101 Semiconductor Protection fuses, rated up to 1000A, 1500VAC/DC are suitable for traction drive and auxiliary circuits and for high voltage heavy duty rectifier applications. A150X fuses are suitable for use up to 1500VDC on circuits depending on time constant.

DC UL Recognized Component UL File E60314; Heavy duty links; Rugged fiberglass body; DC UL Recognized 10A-600A@1500VDC L/R<2ms,100kA; 1500VAC/DC rated for wide range of applications; Mersen self certified 1000 VDC

$1,598.57 /EA