15.5kV 300E E-RATED BOLT In

15.5kV 300E E-RATED BOLT In

Item #: A155B3D0R0-300E

Supplier Part #: A155B3D0R0-300E
Brand: Mersen

Mersen fuses for the protection of transformers and distribution lines deliver overload and short circuit protection. These current-limiting fuses will melt at current that can be as low as 1.7 times the fuse current ratings up to its maximum interrupting rating. These fuses are designed to withstand the transformer magnetizing inrush current. They are single, double, triple or quadruple barrels 3 inch diameter (size D) with end mounts designed for bolting directly to equipment bus or terminal pads.

UL listed for compatibility with UL listed equipment; Non-venting for silent operation; Some UL Listed to standard E143362; Bolt-In mounting for direct connection to bus or terminals; Outdoor usage for the 9F62; Metal embossed catalog number and manufacturing date for lasting identification; Current-limiting for superior equipment protection; Blown-fuse indicator to give positive identification of open fuse

$5,047.07 /EA
NOT CURRENTLY IN STOCK
15.5KV 32X X-RATED BOLT IN

15.5KV 32X X-RATED BOLT IN

Item #: A155B4D0R0-32X

Supplier Part #: A155B4D0R0-32X
Brand: Mersen

Mersen R-Rated fuses are current-limiting, high interrupting rating fuses intended for the short circuit protection of medium voltage motors and motor controllers. R-Rated fuses are back-up fuses that have a minimum interrupting rating, and must be coordinated with overload relays in combination motor starters. The motor starter manufacturer generally specifies the R-Rated fuse size. These fuses are single, double, triple or quadruple barrels 3 inches diameter with end mounts designed for bolting directly to equipment bus or terminal pads

Current-limiting for superior equipment protection; UL Recognized File E93367; Metal embossed catalog number and manufacturing date for lasting identification; Bolt-in mounting for direct connection to bus or terminals; Blown-fuse indicator to give positive identification of open fuse; The Amp-Trap Bolt-in series are UL Recognized

$16,781.29 /EA
NOT CURRENTLY IN STOCK
15.5KV 38X X-RATED BOLT IN

15.5KV 38X X-RATED BOLT IN

Item #: A155B4D0R0-38X

Supplier Part #: A155B4D0R0-38X
Brand: Mersen

Mersen R-Rated fuses are current-limiting, high interrupting rating fuses intended for the short circuit protection of medium voltage motors and motor controllers. R-Rated fuses are back-up fuses that have a minimum interrupting rating, and must be coordinated with overload relays in combination motor starters. The motor starter manufacturer generally specifies the R-Rated fuse size. These fuses are single, double, triple or quadruple barrels 3 inches diameter with end mounts designed for bolting directly to equipment bus or terminal pads

Blown-fuse indicator to give positive identification of open fuse; Bolt-in mounting for direct connection to bus or terminals; UL Recognized File E93367; Metal embossed catalog number and manufacturing date for lasting identification; Current-limiting for superior equipment protection; The Amp-Trap Bolt-in series are UL Recognized

$17,641.09 /EA
NOT CURRENTLY IN STOCK
15.5KV 100E RATED CLIP-LOCK

15.5KV 100E RATED CLIP-LOCK

Item #: A155C1D0R0-100E

Supplier Part #: A155C1D0R0-100E
Brand: Mersen

Mersen Amp-Trap fuses for the protection of transformers and distribution lines deliver overload and short circuit protection. These general purpose current-limiting fuses will melt at current that can be as low as 1.7 times the fuse current ratings up to its maximum interrupting rating. These fuses are designed to withstand the transformer magnetizing inrush current. They are single, double or triple barrels 3 inch diameter (size D) and mount in unique cam-locking clips for superior connections as well as easy installation and replacement.

Blown-fuse indicator to give positive identification of open fuse; Clip-lock mounting for reliable high integrity connection into circuit; Current-limiting for superior equipment protection; 2 lb tripped force – 0.50 Inch; Non-venting for silent operation; Some UL Listed to standard File E143362; Metal embossed catalog number and manufacturing date for lasting identification; UL listed for compatibility with UL listed equipment

$2,407.11 /EA
NOT CURRENTLY IN STOCK
15.5KV 10E RATED CLIP-LOCK

15.5KV 10E RATED CLIP-LOCK

Item #: A155C1D0R0-10E

Supplier Part #: A155C1D0R0-10E
Brand: Mersen

Mersen Amp-Trap fuses for the protection of transformers and distribution lines deliver overload and short circuit protection. These general purpose current-limiting fuses will melt at current that can be as low as 1.7 times the fuse current ratings up to its maximum interrupting rating. These fuses are designed to withstand the transformer magnetizing inrush current. They are single, double or triple barrels 3 inch diameter (size D) and mount in unique cam-locking clips for superior connections as well as easy installation and replacement.

Blown-fuse indicator to give positive identification of open fuse; Clip-lock mounting for reliable high integrity connection into circuit; 2 lb tripped force – 0.50 Inch; Current-limiting for superior equipment protection; Metal embossed catalog number and manufacturing date for lasting identification; Non-venting for silent operation; UL listed for compatibility with UL listed equipment; Some UL Listed to standard File E143362

$762.77 /EA
NOT CURRENTLY IN STOCK
15.5KV 20E RATED CLIP-LOCK

15.5KV 20E RATED CLIP-LOCK

Item #: A155C1D0R0-20E

Supplier Part #: A155C1D0R0-20E
Brand: Mersen

Mersen Amp-Trap fuses for the protection of transformers and distribution lines deliver overload and short circuit protection. These general purpose current-limiting fuses will melt at current that can be as low as 1.7 times the fuse current ratings up to its maximum interrupting rating. These fuses are designed to withstand the transformer magnetizing inrush current. They are single, double or triple barrels 3 inch diameter (size D) and mount in unique cam-locking clips for superior connections as well as easy installation and replacement.

Current-limiting for superior equipment protection; UL listed for compatibility with UL listed equipment; Metal embossed catalog number and manufacturing date for lasting identification; 2 lb tripped force – 0.50 Inch; Blown-fuse indicator to give positive identification of open fuse; Non-venting for silent operation; Clip-lock mounting for reliable high integrity connection into circuit; Some UL Listed to standard File E143362

$1,800.87 /EA
NOT CURRENTLY IN STOCK
15.5KV 25E RATED CLIP-LOCK

15.5KV 25E RATED CLIP-LOCK

Item #: A155C1D0R0-25E

Supplier Part #: A155C1D0R0-25E
Brand: Mersen

Mersen Amp-Trap fuses for the protection of transformers and distribution lines deliver overload and short circuit protection. These general purpose current-limiting fuses will melt at current that can be as low as 1.7 times the fuse current ratings up to its maximum interrupting rating. These fuses are designed to withstand the transformer magnetizing inrush current. They are single, double or triple barrels 3 inch diameter (size D) and mount in unique cam-locking clips for superior connections as well as easy installation and replacement.

Metal embossed catalog number and manufacturing date for lasting identification; Some UL Listed to standard File E143362; Current-limiting for superior equipment protection; Clip-lock mounting for reliable high integrity connection into circuit; Non-venting for silent operation; Blown-fuse indicator to give positive identification of open fuse; 2 lb tripped force – 0.50 Inch; UL listed for compatibility with UL listed equipment

$1,800.87 /EA
NOT CURRENTLY IN STOCK
15.5KV 30E RATED CLIP-LOCK

15.5KV 30E RATED CLIP-LOCK

Item #: A155C1D0R0-30E

Supplier Part #: A155C1D0R0-30E
Brand: Mersen

Mersen Amp-Trap fuses for the protection of transformers and distribution lines deliver overload and short circuit protection. These general purpose current-limiting fuses will melt at current that can be as low as 1.7 times the fuse current ratings up to its maximum interrupting rating. These fuses are designed to withstand the transformer magnetizing inrush current. They are single, double or triple barrels 3 inch diameter (size D) and mount in unique cam-locking clips for superior connections as well as easy installation and replacement.

2 lb tripped force – 0.50 Inch; Clip-lock mounting for reliable high integrity connection into circuit; UL listed for compatibility with UL listed equipment; Metal embossed catalog number and manufacturing date for lasting identification; Blown-fuse indicator to give positive identification of open fuse; Some UL Listed to standard File E143362; Current-limiting for superior equipment protection; Non-venting for silent operation

$1,800.87 /EA
NOT CURRENTLY IN STOCK
15.5KV 40E RATED CLIP-LOCK

15.5KV 40E RATED CLIP-LOCK

Item #: A155C1D0R0-40E

Supplier Part #: A155C1D0R0-40E
Brand: Mersen

Mersen Amp-Trap fuses for the protection of transformers and distribution lines deliver overload and short circuit protection. These general purpose current-limiting fuses will melt at current that can be as low as 1.7 times the fuse current ratings up to its maximum interrupting rating. These fuses are designed to withstand the transformer magnetizing inrush current. They are single, double or triple barrels 3 inch diameter (size D) and mount in unique cam-locking clips for superior connections as well as easy installation and replacement.

2 lb tripped force – 0.50 Inch; Non-venting for silent operation; Clip-lock mounting for reliable high integrity connection into circuit; UL listed for compatibility with UL listed equipment; Metal embossed catalog number and manufacturing date for lasting identification; Some UL Listed to standard File E143362; Blown-fuse indicator to give positive identification of open fuse; Current-limiting for superior equipment protection

$1,800.87 /EA
NOT CURRENTLY IN STOCK
15.5KV 50E RATED CLIP-LOCK

15.5KV 50E RATED CLIP-LOCK

Item #: A155C1D0R0-50E

Supplier Part #: A155C1D0R0-50E
Brand: Mersen

Mersen Amp-Trap fuses for the protection of transformers and distribution lines deliver overload and short circuit protection. These general purpose current-limiting fuses will melt at current that can be as low as 1.7 times the fuse current ratings up to its maximum interrupting rating. These fuses are designed to withstand the transformer magnetizing inrush current. They are single, double or triple barrels 3 inch diameter (size D) and mount in unique cam-locking clips for superior connections as well as easy installation and replacement.

Clip-lock mounting for reliable high integrity connection into circuit; Blown-fuse indicator to give positive identification of open fuse; UL listed for compatibility with UL listed equipment; Metal embossed catalog number and manufacturing date for lasting identification; 2 lb tripped force – 0.50 Inch; Current-limiting for superior equipment protection; Some UL Listed to standard File E143362; Non-venting for silent operation

$2,407.11 /EA