Browse Categories

Search in Category

Fuses

Search Filters

  • 0.2 lb x

Shop by Category

Loading...

Fuses

Power Products/Fuses 
Viewing Page 3 of 14 (139 results)

600V 1-6/10A CLASS J TD FUSE

Item #: AJT1-6/10

Supplier Part #: AJT1-6/10
Brand: Mersen

Amp-Trap 2000® AJT fuses provide non-indication as well as a SmartSpot visual open fuse indicator. With advanced material technology the AJT fuse provides IEC Type 2 No Damage protection to main, feeder, and branch circuits, for all types of loads — yet, they require only half the mounting space needed for 600VAC Class RK fuses. AJT’s time-delay characteristics are ideal for handling typical motor and transformer inrush currents, while also providing superior current-limiting ability.

UL listed to standard 248-8 File E2137; Unique Class J dimensions prevent replacement errors; Control panels; Mains; 300kA interrupting rating – self-certified, UL witnessed tests; Motor circuits; UL listed; DC tested to UL standard 248; Transformers; CSA certified to standard C22.2 No. 248.8; Optional EI indicator/switch mount for AJT70 to 600 open fuse indication; High-grade silica filler ensures fast arc quenching; Most current-limiting UL class fuse; Branch circuits; IEC 60269-2-1; Non-indicating or solid state SmartSpot visual blown fuse indicator; Metal-embossed date and catalog number for traceability and lasting identification; Extremely current-limiting for low peak let-thru current; Approvals & Standards; DC listed to UL standard 248; Feeders; Circuit breaker back-up; Time-delay for motor starting and transformer inrush; Recommended for Arc Flash energy reduction; Small footprint requires less mounting space and allows smaller, more economical fuse blocks; Easy 2-to-1 selectivity for prevention of nuisance shutdowns; Fiberglass body provides dimensional stability in harsh industrial settings; Lighting, heating & general loads; Bus duct; Load centers; High-visibility orange label gives instant brand recognition

$20.95 /EA
NOT CURRENTLY IN STOCK

600V 1-8/10A CLASS J TD FUSE

Item #: AJT1-8/10

Supplier Part #: AJT1-8/10
Brand: Mersen

Amp-Trap 2000® AJT fuses provide non-indication as well as a SmartSpot visual open fuse indicator. With advanced material technology the AJT fuse provides IEC Type 2 No Damage protection to main, feeder, and branch circuits, for all types of loads — yet, they require only half the mounting space needed for 600VAC Class RK fuses. AJT’s time-delay characteristics are ideal for handling typical motor and transformer inrush currents, while also providing superior current-limiting ability.

DC listed to UL standard 248; CSA certified to standard C22.2 No. 248.8; UL listed; Feeders; Recommended for Arc Flash energy reduction; Mains; DC tested to UL standard 248; Branch circuits; Non-indicating or solid state SmartSpot visual blown fuse indicator; Small footprint requires less mounting space and allows smaller, more economical fuse blocks; Circuit breaker back-up; 300kA interrupting rating – self-certified, UL witnessed tests; UL listed to standard 248-8 File E2137; High-grade silica filler ensures fast arc quenching; Control panels; Fiberglass body provides dimensional stability in harsh industrial settings; Extremely current-limiting for low peak let-thru current; IEC 60269-2-1; High-visibility orange label gives instant brand recognition; Load centers; Most current-limiting UL class fuse; Unique Class J dimensions prevent replacement errors; Metal-embossed date and catalog number for traceability and lasting identification; Time-delay for motor starting and transformer inrush; Optional EI indicator/switch mount for AJT70 to 600 open fuse indication; Transformers; Motor circuits; Lighting, heating & general loads; Bus duct; Approvals & Standards; Easy 2-to-1 selectivity for prevention of nuisance shutdowns

Call
NOT CURRENTLY IN STOCK

600V 12A CLASS J TD FUSE

Item #: AJT12

Supplier Part #: AJT12
Brand: Mersen

Amp-Trap 2000® AJT fuses provide non-indication as well as a SmartSpot visual open fuse indicator. With advanced material technology the AJT fuse provides IEC Type 2 No Damage protection to main, feeder, and branch circuits, for all types of loads — yet, they require only half the mounting space needed for 600VAC Class RK fuses. AJT’s time-delay characteristics are ideal for handling typical motor and transformer inrush currents, while also providing superior current-limiting ability.

Extremely current-limiting for low peak let-thru current; 300kA interrupting rating – self-certified, UL witnessed tests; Transformers; UL listed to standard 248-8 File E2137; Recommended for Arc Flash energy reduction; DC listed to UL standard 248; Most current-limiting UL class fuse; Branch circuits; Feeders; CSA certified to standard C22.2 No. 248.8; Time-delay for motor starting and transformer inrush; DC tested to UL standard 248; Circuit breaker back-up; Metal-embossed date and catalog number for traceability and lasting identification; Mains; Non-indicating or solid state SmartSpot visual blown fuse indicator; Control panels; Small footprint requires less mounting space and allows smaller, more economical fuse blocks; Optional EI indicator/switch mount for AJT70 to 600 open fuse indication; UL listed; Lighting, heating & general loads; Unique Class J dimensions prevent replacement errors; Motor circuits; Fiberglass body provides dimensional stability in harsh industrial settings; High-grade silica filler ensures fast arc quenching; IEC 60269-2-1; High-visibility orange label gives instant brand recognition; Load centers; Easy 2-to-1 selectivity for prevention of nuisance shutdowns; Bus duct

$41.15 /EA
NOT CURRENTLY IN STOCK

J TD FUSE 600V 17-1/2A AJT

Item #: AJT17-1/2

Supplier Part #: AJT17-1/2
Brand: Mersen

Amp-Trap 2000® AJT fuses provide non-indication as well as a SmartSpot visual open fuse indicator. With advanced material technology the AJT fuse provides IEC Type 2 No Damage protection to main, feeder, and branch circuits, for all types of loads — yet, they require only half the mounting space needed for 600VAC Class RK fuses. AJT’s time-delay characteristics are ideal for handling typical motor and transformer inrush currents, while also providing superior current-limiting ability.

Mains; UL listed to standard 248-8 File E2137; Unique Class J dimensions prevent replacement errors; Time-delay for motor starting and transformer inrush; Extremely current-limiting for low peak let-thru current; Bus duct; High-grade silica filler ensures fast arc quenching; IEC 60269-2-1; CSA certified to standard C22.2 No. 248.8; Small footprint requires less mounting space and allows smaller, more economical fuse blocks; UL listed; Transformers; DC tested to UL standard 248; Load centers; Most current-limiting UL class fuse; Recommended for Arc Flash energy reduction; Circuit breaker back-up; DC listed to UL standard 248; Non-indicating or solid state SmartSpot visual blown fuse indicator; 300kA interrupting rating – self-certified, UL witnessed tests; Easy 2-to-1 selectivity for prevention of nuisance shutdowns; Fiberglass body provides dimensional stability in harsh industrial settings; Lighting, heating & general loads; Metal-embossed date and catalog number for traceability and lasting identification; Optional EI indicator/switch mount for AJT70 to 600 open fuse indication; Feeders; Control panels; Motor circuits; Branch circuits; High-visibility orange label gives instant brand recognition

$39.28 /EA
NOT CURRENTLY IN STOCK

600V 2A CLASS J TD FUSE

Item #: AJT2

Supplier Part #: AJT2
Brand: Mersen

Amp-Trap 2000® AJT fuses provide non-indication as well as a SmartSpot visual open fuse indicator. With advanced material technology the AJT fuse provides IEC Type 2 No Damage protection to main, feeder, and branch circuits, for all types of loads — yet, they require only half the mounting space needed for 600VAC Class RK fuses. AJT’s time-delay characteristics are ideal for handling typical motor and transformer inrush currents, while also providing superior current-limiting ability.

Bus duct; Unique Class J dimensions prevent replacement errors; UL listed; Control panels; UL listed to standard 248-8 File E2137; Most current-limiting UL class fuse; Mains; Approvals & Standards; DC tested to UL standard 248; Small footprint requires less mounting space and allows smaller, more economical fuse blocks; Extremely current-limiting for low peak let-thru current; Time-delay for motor starting and transformer inrush; Feeders; Motor circuits; High-grade silica filler ensures fast arc quenching; Non-indicating or solid state SmartSpot visual blown fuse indicator; Branch circuits; Load centers; Fiberglass body provides dimensional stability in harsh industrial settings; Recommended for Arc Flash energy reduction; Transformers; IEC 60269-2-1; Optional EI indicator/switch mount for AJT70 to 600 open fuse indication; Circuit breaker back-up; CSA certified to standard C22.2 No. 248.8; Metal-embossed date and catalog number for traceability and lasting identification; High-visibility orange label gives instant brand recognition; Lighting, heating & general loads; 300kA interrupting rating – self-certified, UL witnessed tests; Easy 2-to-1 selectivity for prevention of nuisance shutdowns; DC listed to UL standard 248

Call
NOT CURRENTLY IN STOCK

600V 2-1/2A CLASS J TD FU

Item #: AJT2-1/2

Supplier Part #: AJT2-1/2
Brand: Mersen

Amp-Trap 2000® AJT fuses provide non-indication as well as a SmartSpot visual open fuse indicator. With advanced material technology the AJT fuse provides IEC Type 2 No Damage protection to main, feeder, and branch circuits, for all types of loads — yet, they require only half the mounting space needed for 600VAC Class RK fuses. AJT’s time-delay characteristics are ideal for handling typical motor and transformer inrush currents, while also providing superior current-limiting ability.

Extremely current-limiting for low peak let-thru current; IEC 60269-2-1; Circuit breaker back-up; Load centers; Time-delay for motor starting and transformer inrush; Fiberglass body provides dimensional stability in harsh industrial settings; Lighting, heating & general loads; Non-indicating or solid state SmartSpot visual blown fuse indicator; Control panels; High-grade silica filler ensures fast arc quenching; Motor circuits; Feeders; Unique Class J dimensions prevent replacement errors; Mains; Bus duct; Most current-limiting UL class fuse; Optional EI indicator/switch mount for AJT70 to 600 open fuse indication; Easy 2-to-1 selectivity for prevention of nuisance shutdowns; Branch circuits; Small footprint requires less mounting space and allows smaller, more economical fuse blocks; Metal-embossed date and catalog number for traceability and lasting identification; DC tested to UL standard 248; UL listed; 300kA interrupting rating – self-certified, UL witnessed tests; High-visibility orange label gives instant brand recognition; Approvals & Standards; Recommended for Arc Flash energy reduction; DC listed to UL standard 248; CSA certified to standard C22.2 No. 248.8; Transformers; UL listed to standard 248-8 File E2137

$20.95 /EA
NOT CURRENTLY IN STOCK

600V 2-1/4A CLASS J TD FUSE

Item #: AJT2-1/4

Supplier Part #: AJT2-1/4
Brand: Mersen

Amp-Trap 2000® AJT fuses provide non-indication as well as a SmartSpot visual open fuse indicator. With advanced material technology the AJT fuse provides IEC Type 2 No Damage protection to main, feeder, and branch circuits, for all types of loads — yet, they require only half the mounting space needed for 600VAC Class RK fuses. AJT’s time-delay characteristics are ideal for handling typical motor and transformer inrush currents, while also providing superior current-limiting ability.

Fiberglass body provides dimensional stability in harsh industrial settings; IEC 60269-2-1; DC listed to UL standard 248; Branch circuits; High-grade silica filler ensures fast arc quenching; Circuit breaker back-up; Load centers; UL listed to standard 248-8 File E2137; Small footprint requires less mounting space and allows smaller, more economical fuse blocks; Extremely current-limiting for low peak let-thru current; Lighting, heating & general loads; Most current-limiting UL class fuse; Metal-embossed date and catalog number for traceability and lasting identification; CSA certified to standard C22.2 No. 248.8; UL listed; Bus duct; Unique Class J dimensions prevent replacement errors; Transformers; High-visibility orange label gives instant brand recognition; DC tested to UL standard 248; 300kA interrupting rating – self-certified, UL witnessed tests; Mains; Non-indicating or solid state SmartSpot visual blown fuse indicator; Optional EI indicator/switch mount for AJT70 to 600 open fuse indication; Time-delay for motor starting and transformer inrush; Recommended for Arc Flash energy reduction; Easy 2-to-1 selectivity for prevention of nuisance shutdowns; Control panels; Motor circuits; Feeders; Approvals & Standards

Call
NOT CURRENTLY IN STOCK

600V 2-8/10A CLASS J TD FUSE

Item #: AJT2-8/10

Supplier Part #: AJT2-8/10
Brand: Mersen

Amp-Trap 2000® AJT fuses provide non-indication as well as a SmartSpot visual open fuse indicator. With advanced material technology the AJT fuse provides IEC Type 2 No Damage protection to main, feeder, and branch circuits, for all types of loads — yet, they require only half the mounting space needed for 600VAC Class RK fuses. AJT’s time-delay characteristics are ideal for handling typical motor and transformer inrush currents, while also providing superior current-limiting ability.

Control panels; Load centers; Approvals & Standards; Motor circuits; Branch circuits; 300kA interrupting rating – self-certified, UL witnessed tests; Easy 2-to-1 selectivity for prevention of nuisance shutdowns; Unique Class J dimensions prevent replacement errors; Optional EI indicator/switch mount for AJT70 to 600 open fuse indication; Time-delay for motor starting and transformer inrush; Bus duct; IEC 60269-2-1; Fiberglass body provides dimensional stability in harsh industrial settings; UL listed to standard 248-8 File E2137; High-grade silica filler ensures fast arc quenching; DC tested to UL standard 248; Lighting, heating & general loads; DC listed to UL standard 248; Circuit breaker back-up; Mains; Recommended for Arc Flash energy reduction; Extremely current-limiting for low peak let-thru current; Small footprint requires less mounting space and allows smaller, more economical fuse blocks; CSA certified to standard C22.2 No. 248.8; Feeders; Transformers; Non-indicating or solid state SmartSpot visual blown fuse indicator; Most current-limiting UL class fuse; High-visibility orange label gives instant brand recognition; Metal-embossed date and catalog number for traceability and lasting identification; UL listed

Call
NOT CURRENTLY IN STOCK

600V 3A CLASS J TD FUSE

Item #: AJT3

Supplier Part #: AJT3
Brand: Mersen

Amp-Trap 2000® AJT fuses provide non-indication as well as a SmartSpot visual open fuse indicator. With advanced material technology the AJT fuse provides IEC Type 2 No Damage protection to main, feeder, and branch circuits, for all types of loads — yet, they require only half the mounting space needed for 600VAC Class RK fuses. AJT’s time-delay characteristics are ideal for handling typical motor and transformer inrush currents, while also providing superior current-limiting ability.

Time-delay for motor starting and transformer inrush; Unique Class J dimensions prevent replacement errors; DC tested to UL standard 248; Feeders; High-visibility orange label gives instant brand recognition; Transformers; Control panels; UL listed; Branch circuits; High-grade silica filler ensures fast arc quenching; CSA certified to standard C22.2 No. 248.8; Approvals & Standards; Circuit breaker back-up; Lighting, heating & general loads; Non-indicating or solid state SmartSpot visual blown fuse indicator; Motor circuits; Load centers; Metal-embossed date and catalog number for traceability and lasting identification; IEC 60269-2-1; Easy 2-to-1 selectivity for prevention of nuisance shutdowns; DC listed to UL standard 248; Extremely current-limiting for low peak let-thru current; Recommended for Arc Flash energy reduction; Bus duct; Small footprint requires less mounting space and allows smaller, more economical fuse blocks; Most current-limiting UL class fuse; 300kA interrupting rating – self-certified, UL witnessed tests; Mains; Fiberglass body provides dimensional stability in harsh industrial settings; UL listed to standard 248-8 File E2137; Optional EI indicator/switch mount for AJT70 to 600 open fuse indication

Call
NOT CURRENTLY IN STOCK

600V 3-1/2A CLASS J TD FUSE

Item #: AJT3-1/2

Supplier Part #: AJT3-1/2
Brand: Mersen

Amp-Trap 2000® AJT fuses provide non-indication as well as a SmartSpot visual open fuse indicator. With advanced material technology the AJT fuse provides IEC Type 2 No Damage protection to main, feeder, and branch circuits, for all types of loads — yet, they require only half the mounting space needed for 600VAC Class RK fuses. AJT’s time-delay characteristics are ideal for handling typical motor and transformer inrush currents, while also providing superior current-limiting ability.

UL listed; Fiberglass body provides dimensional stability in harsh industrial settings; Control panels; Unique Class J dimensions prevent replacement errors; Most current-limiting UL class fuse; Extremely current-limiting for low peak let-thru current; Time-delay for motor starting and transformer inrush; Circuit breaker back-up; Feeders; Approvals & Standards; UL listed to standard 248-8 File E2137; High-grade silica filler ensures fast arc quenching; DC tested to UL standard 248; Load centers; CSA certified to standard C22.2 No. 248.8; Non-indicating or solid state SmartSpot visual blown fuse indicator; Metal-embossed date and catalog number for traceability and lasting identification; DC listed to UL standard 248; Transformers; Branch circuits; Small footprint requires less mounting space and allows smaller, more economical fuse blocks; Motor circuits; 300kA interrupting rating – self-certified, UL witnessed tests; Optional EI indicator/switch mount for AJT70 to 600 open fuse indication; High-visibility orange label gives instant brand recognition; Bus duct; IEC 60269-2-1; Easy 2-to-1 selectivity for prevention of nuisance shutdowns; Lighting, heating & general loads; Mains; Recommended for Arc Flash energy reduction

Call
NOT CURRENTLY IN STOCK
  • « PREV
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • NEXT »