74836-FUSE,TRIONIC
Time-delay for motor start-ups and high inrush loads without nuisance opening; Rail heaters; Pump motors; Trailing cables; Mine circuits; DC rated for mine duty and other long time-constant applications; Rugged glass melamine body for superior reliability in harsh environments; MSHA approval no. 28-26-0
600V 80A TD RK5 FUSE SMARTSPOT
General-purpose equipment; DC listed to UL standard 248 TRS only; Rejection-style design prevents replacement errors (when used with recommended fuse blocks); High-grade silica filler ensures fast arc quenching and high current limitation; AC & DC rated; Current-limiting; Feeders; Optional solid state SmartSpot blown fuse indicator; Mains; Service entrance equipment; Fiberglass body provides dimensional stability in harsh industrial settings; Current-limiting for low peak let-thru current; Branch circuits; UL listed to standard 248-12 File E2137; Motor circuits; Easy-to-read label for quick brand recognition and replacement; Transformers; Time-delay for motor start-ups and transformer inrush currents without nuisance opening; Metal-embossed date and catalog number for traceability and lasting identification; CSA certified to standard C22.2 no. 248.12; Time-delay
600V 90A 7 7/8x1 5/16 TD
Service entrance equipment; Motor circuits; Rejection-style design prevents replacement errors (when used with recommended fuse blocks); Optional solid state SmartSpot blown fuse indicator; UL listed to standard 248-12 File E2137; Time-delay for motor start-ups and transformer inrush currents without nuisance opening; High-grade silica filler ensures fast arc quenching and high current limitation; Time-delay; Branch circuits; DC listed to UL standard 248 TRS only; Easy-to-read label for quick brand recognition and replacement; General-purpose equipment; CSA certified to standard C22.2 no. 248.12; Mains; AC & DC rated; Current-limiting; Transformers; Current-limiting for low peak let-thru current; Fiberglass body provides dimensional stability in harsh industrial settings; Metal-embossed date and catalog number for traceability and lasting identification; Feeders
74837-FUSE,TRIONIC
Rugged glass melamine body for superior reliability in harsh environments; Rail heaters; Mine circuits; Pump motors; DC rated for mine duty and other long time-constant applications; Time-delay for motor start-ups and high inrush loads without nuisance opening; MSHA approval no. 28-26-0; Trailing cables
600V 90A TD RK5 FUSE SMARTSPOT
Mains; UL listed to standard 248-12 File E2137; Current-limiting for low peak let-thru current; CSA certified to standard C22.2 no. 248.12; Feeders; Time-delay; High-grade silica filler ensures fast arc quenching and high current limitation; Time-delay for motor start-ups and transformer inrush currents without nuisance opening; General-purpose equipment; Optional solid state SmartSpot blown fuse indicator; Fiberglass body provides dimensional stability in harsh industrial settings; Transformers; Branch circuits; DC listed to UL standard 248 TRS only; AC & DC rated; Metal-embossed date and catalog number for traceability and lasting identification; Rejection-style design prevents replacement errors (when used with recommended fuse blocks); Motor circuits; Current-limiting; Service entrance equipment; Easy-to-read label for quick brand recognition and replacement
H FUSE 600V 100A NRS
250V and 600V applications; Type “P” (15 – 60A); Non-time delay
H FUSE 600V 70A NRS
250V and 600V applications; Type “P” (15 – 60A); Non-time delay
H FUSE 600V 80A NRS
Type “P” (15 – 60A); 250V and 600V applications; Non-time delay
H FUSE 600V 90A NRS
Non-time delay; 250V and 600V applications; Type “P” (15 – 60A)
600V 100A 7 7/8x1 5/16 K5FUSE
Residential and small commercial installations; Feeders; Low cost for high protection value; Easy to read imprint label for quick recognition and replacement; Branch circuits; UL Listed to Standard 248-9 File E2137; CSA Certified to Standard C22.2 No. 248.9 (The Canadian Electrical Code requires these fuses in ratings 15 through 60A to be of the low melting point design; use OTN 15-60.); Self-certified for DC per UL248; Resistive heating