600V 300A TD RK5 FUSE SMARTSPO

600V 300A TD RK5 FUSE SMARTSPO

Item #: TRS300RID

Supplier Part #: TRS300RID
Brand: Mersen

Tri-Onic TRS-R current-limiting time-delay fuses are engineered for overcurrent protection of motors, transformers, service entrance equipment, feeders and branch-circuits. The time-delay characteristics of the TRS-R safely handle harmless starting currents and inrush currents associated with today's motors and transformers.

Service entrance equipment; Time-delay for motor start-ups and transformer inrush currents without nuisance opening; Mains; Current-limiting for low peak let-thru current; AC & DC rated; Easy-to-read label for quick brand recognition and replacement; UL listed to standard 248-12 File E2137; DC listed to UL standard 248 TRS only; Transformers; Optional solid state SmartSpot blown fuse indicator; Current-limiting; Metal-embossed date and catalog number for traceability and lasting identification; Feeders; Motor circuits; High-grade silica filler ensures fast arc quenching and high current limitation; CSA certified to standard C22.2 no. 248.12; Fiberglass body provides dimensional stability in harsh industrial settings; Branch circuits; Rejection-style design prevents replacement errors (when used with recommended fuse blocks); General-purpose equipment; Time-delay

$348.64 /EA
NOT CURRENTLY IN STOCK
600V 350A 11 5/8x2 9/16 T

600V 350A 11 5/8x2 9/16 T

Item #: TRS350R

Supplier Part #: TRS350R
Brand: Mersen

Tri-Onic TRS-R current-limiting time-delay fuses are engineered for overcurrent protection of motors, transformers, service entrance equipment, feeders and branch-circuits. The time-delay characteristics of the TRS-R safely handle harmless starting currents and inrush currents associated with today's motors and transformers.

Easy-to-read label for quick brand recognition and replacement; UL listed to standard 248-12 File E2137; Rejection-style design prevents replacement errors (when used with recommended fuse blocks); DC listed to UL standard 248 TRS only; Service entrance equipment; Optional solid state SmartSpot blown fuse indicator; Branch circuits; AC & DC rated; Mains; General-purpose equipment; Time-delay for motor start-ups and transformer inrush currents without nuisance opening; High-grade silica filler ensures fast arc quenching and high current limitation; Current-limiting; Motor circuits; Metal-embossed date and catalog number for traceability and lasting identification; Transformers; CSA certified to standard C22.2 no. 248.12; Current-limiting for low peak let-thru current; Time-delay; Fiberglass body provides dimensional stability in harsh industrial settings; Feeders

$335.58 /EA
NOT CURRENTLY IN STOCK
600V 350A TD RK5 FUSE SMARTSPO

600V 350A TD RK5 FUSE SMARTSPO

Item #: TRS350RID

Supplier Part #: TRS350RID
Brand: Mersen

Tri-Onic TRS-R current-limiting time-delay fuses are engineered for overcurrent protection of motors, transformers, service entrance equipment, feeders and branch-circuits. The time-delay characteristics of the TRS-R safely handle harmless starting currents and inrush currents associated with today's motors and transformers.

High-grade silica filler ensures fast arc quenching and high current limitation; Easy-to-read label for quick brand recognition and replacement; Time-delay for motor start-ups and transformer inrush currents without nuisance opening; Metal-embossed date and catalog number for traceability and lasting identification; Mains; Branch circuits; Rejection-style design prevents replacement errors (when used with recommended fuse blocks); Fiberglass body provides dimensional stability in harsh industrial settings; DC listed to UL standard 248 TRS only; Service entrance equipment; Current-limiting; Motor circuits; Time-delay; Transformers; Current-limiting for low peak let-thru current; General-purpose equipment; UL listed to standard 248-12 File E2137; AC & DC rated; Feeders; CSA certified to standard C22.2 no. 248.12; Optional solid state SmartSpot blown fuse indicator

$348.64 /EA
NOT CURRENTLY IN STOCK
600V 400A TD RK5 FUSE SMARTSPO

600V 400A TD RK5 FUSE SMARTSPO

Item #: TRS400RID

Supplier Part #: TRS400RID
Brand: Mersen

Tri-Onic TRS-R current-limiting time-delay fuses are engineered for overcurrent protection of motors, transformers, service entrance equipment, feeders and branch-circuits. The time-delay characteristics of the TRS-R safely handle harmless starting currents and inrush currents associated with today's motors and transformers.

Current-limiting for low peak let-thru current; UL listed to standard 248-12 File E2137; Transformers; Mains; Fiberglass body provides dimensional stability in harsh industrial settings; Time-delay; General-purpose equipment; Feeders; AC & DC rated; Rejection-style design prevents replacement errors (when used with recommended fuse blocks); Service entrance equipment; CSA certified to standard C22.2 no. 248.12; Branch circuits; DC listed to UL standard 248 TRS only; Easy-to-read label for quick brand recognition and replacement; Motor circuits; Time-delay for motor start-ups and transformer inrush currents without nuisance opening; Current-limiting; Optional solid state SmartSpot blown fuse indicator; High-grade silica filler ensures fast arc quenching and high current limitation; Metal-embossed date and catalog number for traceability and lasting identification

$348.64 /EA
NOT CURRENTLY IN STOCK
600V 300A 11 5/8x2 9/16 T

600V 300A 11 5/8x2 9/16 T

Item #: TRS300R

Supplier Part #: TRS300R
Brand: Mersen

Tri-Onic TRS-R current-limiting time-delay fuses are engineered for overcurrent protection of motors, transformers, service entrance equipment, feeders and branch-circuits. The time-delay characteristics of the TRS-R safely handle harmless starting currents and inrush currents associated with today's motors and transformers.

Easy-to-read label for quick brand recognition and replacement; CSA certified to standard C22.2 no. 248.12; Transformers; DC listed to UL standard 248 TRS only; Current-limiting for low peak let-thru current; Mains; Service entrance equipment; Branch circuits; Motor circuits; Time-delay for motor start-ups and transformer inrush currents without nuisance opening; Time-delay; Rejection-style design prevents replacement errors (when used with recommended fuse blocks); UL listed to standard 248-12 File E2137; Optional solid state SmartSpot blown fuse indicator; Current-limiting; High-grade silica filler ensures fast arc quenching and high current limitation; Fiberglass body provides dimensional stability in harsh industrial settings; Feeders; General-purpose equipment; AC & DC rated; Metal-embossed date and catalog number for traceability and lasting identification

$335.58 /EA
NOT CURRENTLY IN STOCK
74894-FUSE,TRIONIC

74894-FUSE,TRIONIC

Item #: TRS300RDC

Supplier Part #: TRS300RDC
Brand: Mersen

Tri-OnicĀ® TRS-RDC time-delay fuse is designed for DC circuit protection in surface and underground mines. The TRS-RDC is MSHA approved and meets the industry's most severe third party requirements for 600VDC rated fuses.

MSHA approval no. 28-26-0; Pump motors; Rugged glass melamine body for superior reliability in harsh environments; DC rated for mine duty and other long time-constant applications; Trailing cables; Rail heaters; Mine circuits; Time-delay for motor start-ups and high inrush loads without nuisance opening

$183.19 /EA
NOT CURRENTLY IN STOCK

600V 400A 11 5/8x2 9/16 T

Item #: TRS400R

Supplier Part #: TRS400R
Brand: Mersen

Tri-Onic TRS-R current-limiting time-delay fuses are engineered for overcurrent protection of motors, transformers, service entrance equipment, feeders and branch-circuits. The time-delay characteristics of the TRS-R safely handle harmless starting currents and inrush currents associated with today's motors and transformers.

Motor circuits; AC & DC rated; Fiberglass body provides dimensional stability in harsh industrial settings; Optional solid state SmartSpot blown fuse indicator; Time-delay for motor start-ups and transformer inrush currents without nuisance opening; Mains; Metal-embossed date and catalog number for traceability and lasting identification; Transformers; General-purpose equipment; Rejection-style design prevents replacement errors (when used with recommended fuse blocks); Current-limiting for low peak let-thru current; Easy-to-read label for quick brand recognition and replacement; Current-limiting; Time-delay; High-grade silica filler ensures fast arc quenching and high current limitation; DC listed to UL standard 248 TRS only; Branch circuits; Feeders; Service entrance equipment; CSA certified to standard C22.2 no. 248.12; UL listed to standard 248-12 File E2137

$335.58 /EA
NOT CURRENTLY IN STOCK
74906-FUSE,TRIONIC

74906-FUSE,TRIONIC

Item #: TRS400RDC

Supplier Part #: TRS400RDC
Brand: Mersen

Tri-OnicĀ® TRS-RDC time-delay fuse is designed for DC circuit protection in surface and underground mines. The TRS-RDC is MSHA approved and meets the industry's most severe third party requirements for 600VDC rated fuses.

Rail heaters; Rugged glass melamine body for superior reliability in harsh environments; MSHA approval no. 28-26-0; Mine circuits; Trailing cables; Time-delay for motor start-ups and high inrush loads without nuisance opening; Pump motors; DC rated for mine duty and other long time-constant applications

$366.37 /EA