Search in Category
Filter Your Search
Shop by Category
Fuses
6900 CP GR 1038 0001
Eliminate all overloads; Current limiting; Excellent cycling capability; Extremely fast acting; UL/CSA Recognized Component; Low I²t for improved semiconductor protection; AC: UL Guide No. E76491; gR Class according to IEC 60269-4 and VDE 636-23; IEC 60269-4 Compliance
A050 URD 005 T13 I
With trip-indicator (1 to 30A), a Mersen speciality; IEC standard 60269-1; (higher ratings without blown fuse indicator 10×38gRB – 690VAC); Voltage rating 500-600 VAC; aR-Class according to VDE 636-23 IEC 60269-4; Without blown fuse indication 0.10 up to 0.80 A; IEC standard 60269-4; VDE 636-23
6900 CP GR 1038 00025
Excellent cycling capability; Eliminate all overloads; Extremely fast acting; gR Class according to IEC 60269-4 and VDE 636-23; IEC 60269-4 Compliance; Low I²t for improved semiconductor protection; AC: UL Guide No. E76491; Current limiting; UL/CSA Recognized Component
500V CP 10X38 GG 6A C/I FS
Full range protection; IEC 60269-1 & -2 (electrically only for the range with striker); Approved by Lloyd’s Register of Shipping and Bureau Veritas; Safest and most reliable protection system; Visual indication of fuse operation; Reduced size
690V CP 10X38 GG 4A S/I FS
Visual indication of fuse operation; Full range protection; Safest and most reliable protection system; IEC 60269-1 & -2 (electrically only for the range with striker); Approved by Lloyd’s Register of Shipping and Bureau Veritas; Reduced size
500V CP 10X38 AM 05A S/I FS
Visual indication of fuse operation; Optional indicator; Safest and most reliable protection system; Reduced size; IEC 60269-1 & -2 (electrically only for the range with striker); Approved by various shipping organizations
500V CP 10X38 GG 12A S/I FS
Visual indication of fuse operation; Safest and most reliable protection system; Reduced size; Full range protection; Approved by Lloyd’s Register of Shipping and Bureau Veritas; IEC 60269-1 & -2 (electrically only for the range with striker)
A050 URB 010 T13 I
Without blown fuse indication 0.10 up to 0.80 A; aR-Class according to VDE 636-23 IEC 60269-4; With trip-indicator (1 to 30A), a Mersen speciality; VDE 636-23; IEC standard 60269-4; (higher ratings without blown fuse indicator 10×38gRB – 690VAC); Voltage rating 500-600 VAC; IEC standard 60269-1
6900 CP GR 1038 0005
IEC 60269-4 Compliance; AC: UL Guide No. E76491; Eliminate all overloads; gR Class according to IEC 60269-4 and VDE 636-23; UL/CSA Recognized Component; Current limiting; Extremely fast acting; Excellent cycling capability; Low I²t for improved semiconductor protection
6900 CP GR 1038 0008
UL/CSA Recognized Component; Extremely fast acting; gR Class according to IEC 60269-4 and VDE 636-23; AC: UL Guide No. E76491; Low I²t for improved semiconductor protection; Eliminate all overloads; Current limiting; Excellent cycling capability; IEC 60269-4 Compliance